43 research outputs found
Database Evaluation for Muscle and Nerve Diseases - DEMAND: An academic neuromuscular coding system
Background: A database which documents the diagnosis of neuromuscular patients is useful for determining the types of patients referred to academic centers and for identifying participants for clinical trials and other studies. The ICD-9 or ICD-10 numeric systems are insufficiently detailed for this purpose.
Objective: To develop a database for neuromuscular diagnoses
Methods: We developed a detailed diagnostic coding system for neuromuscular diseases called DEMAND: Database Evaluation for Muscle and Nerve Diseases that has been adopted by neuromuscular clinics at University of Texas Health Science Center San Antonio (UTHSCSA), Ohio State University (OSU), University of Kansas Medical Center (KUMC), and University of Texas Southwestern (UTSW). At the initial visit, patients are assigned a diagnostic code which can be revised later if appropriate. Fields include patient’s name, date of birth, and diagnostic code. The neuromuscular database consisted of 457 codes. Each code has a prefix (MUS or PNS) followed by a three-digit number. Depending on whether muscle or nerve is primarily involved, there are eight broad groups: motor neuron disease (MUS codes 100-139); neuromuscular junction disorders (MUS 200-217); acquired and hereditary myopathies (MUS 300-600s); acquired and hereditary polyneuropathies (PNS 100-400); mononeuropathies (PNS 500s); plexopathies (PNS 600s); radiculopathies (PNS 700s); and mononeuritis multiplex (PNS 800s).
Results: During a period of 10 years, 17,163 of patients were entered (1,752 at UTHSCSA, 1,840 at OSU, 3,699 at KUMC, 9,872 at UTSW). The number of patients in several broad categories are: 3,080 motor neuron disease; 1,575 neuromuscular junction disease; 1,851 muscular dystrophies; 633 inflammatory myopathies; 1,090 hereditary neuropathies; 1,001 immune-mediated polyneuropathies; 620 metabolic/toxic polyneuropathies; 535 mononeuropathies; 296 plexopathies; and 769 radiculopathies.
Conclusion: A detailed diagnostic neuromuscular database can be utilized at multiple academic centers. The database should be simple without too many fields to complete, to ensure compliance during busy clinic operations. This database has been very useful in identifying groups of patients for retrospective, observational studies and for prospective treatment studies including trials for Amyotrophic Lateral Sclerosis (ALS), Muscular Dystrophies (MD), Myasthenia Gravis (MG), and retrospective studies of Primary Lateral Sclerosis (PLS), chronic inflammatory demyelinating neuropathy (CIDP), etc
DC readout experiment in Enhanced LIGO
The two 4 km long gravitational wave detectors operated by the Laser
Interferometer Gravitational-wave Observatory (LIGO) were modified in 2008 to
read out the gravitational wave channel using the DC readout form of homodyne
detection and to include an optical filter cavity at the output of the
detector. As part of the upgrade to Enhanced LIGO, these modifications replaced
the radio-frequency (RF) heterodyne system used previously. We describe the
motivations for and the implementation of DC readout and the output mode
cleaner in Enhanced LIGO. We present characterizations of the system, including
measurements and models of the couplings of the noises from the laser source to
the gravitational wave readout channel. We show that noise couplings using DC
readout are improved over those for RF readout, and we find that the achieved
shot-noise-limited sensitivity is consistent with modeled results
Characterization of systematic error in Advanced LIGO calibration
The raw outputs of the detectors within the Advanced Laser Interferometer
Gravitational-Wave Observatory need to be calibrated in order to produce the
estimate of the dimensionless strain used for astrophysical analyses. The two
detectors have been upgraded since the second observing run and finished the
year-long third observing run. Understanding, accounting, and/or compensating
for the complex-valued response of each part of the upgraded detectors improves
the overall accuracy of the estimated detector response to gravitational waves.
We describe improved understanding and methods used to quantify the response of
each detector, with a dedicated effort to define all places where systematic
error plays a role. We use the detectors as they stand in the first half (six
months) of the third observing run to demonstrate how each identified
systematic error impacts the estimated strain and constrain the statistical
uncertainty therein. For this time period, we estimate the upper limit on
systematic error and associated uncertainty to be in magnitude and deg in phase ( confidence interval) in the most sensitive frequency
band 20-2000 Hz. The systematic error alone is estimated at levels of
in magnitude and deg in phase
Notch Lineages and Activity in Intestinal Stem Cells Determined by a New Set of Knock-In Mice
The conserved role of Notch signaling in controlling intestinal cell fate specification and homeostasis has been extensively studied. Nevertheless, the precise identity of the cells in which Notch signaling is active and the role of different Notch receptor paralogues in the intestine remain ambiguous, due to the lack of reliable tools to investigate Notch expression and function in vivo. We generated a new series of transgenic mice that allowed us, by lineage analysis, to formally prove that Notch1 and Notch2 are specifically expressed in crypt stem cells. In addition, a novel Notch reporter mouse, Hes1-EmGFPSAT, demonstrated exclusive Notch activity in crypt stem cells and absorptive progenitors. This roster of knock-in and reporter mice represents a valuable resource to functionally explore the Notch pathway in vivo in virtually all tissues
Searching for stochastic gravitational waves using data from the two colocated LIGO Hanford detectors
Searches for a stochastic gravitational-wave background (SGWB) using terrestrial detectors typically involve cross-correlating data from pairs of detectors. The sensitivity of such cross-correlation analyses depends, among other things, on the separation between the two detectors: the smaller the separation, the better the sensitivity. Hence, a colocated detector pair is more sensitive to a gravitational-wave background than a noncolocated detector pair. However, colocated detectors are also expected to suffer from correlated noise from instrumental and environmental effects that could contaminate the measurement of the background. Hence, methods to identify and mitigate the effects of correlated noise are necessary to achieve the potential increase in sensitivity of colocated detectors. Here we report on the first SGWB analysis using the two LIGO Hanford detectors and address the complications arising from correlated environmental noise. We apply correlated noise identification and mitigation techniques to data taken by the two LIGO Hanford detectors, H1 and H2, during LIGO’s fifth science run. At low frequencies, 40–460 Hz, we are unable to sufficiently mitigate the correlated noise to a level where we may confidently measure or bound the stochastic gravitational-wave signal. However, at high frequencies, 460–1000 Hz, these techniques are sufficient to set a 95% confidence level upper limit on the gravitational-wave energy density of Ω(f) < 7.7 × 10[superscript -4](f/900 Hz)[superscript 3], which improves on the previous upper limit by a factor of ~180. In doing so, we demonstrate techniques that will be useful for future searches using advanced detectors, where correlated noise (e.g., from global magnetic fields) may affect even widely separated detectors.National Science Foundation (U.S.)United States. National Aeronautics and Space AdministrationCarnegie TrustDavid & Lucile Packard FoundationAlfred P. Sloan Foundatio
Properties of the Binary Black Hole Merger GW150914
On September 14, 2015, the Laser Interferometer Gravitational-Wave Observatory (LIGO) detected a gravitational-wave transient (GW150914); we characterize the properties of the source and its parameters. The data around the time of the event were analyzed coherently across the LIGO network using a suite of accurate waveform models that describe gravitational waves from a compact binary system in general relativity. GW150914 was produced by a nearly equal mass binary black hole of masses 36+5−4M⊙ and 29+4−4M⊙; for each parameter we report the median value and the range of the 90% credible interval. The dimensionless spin magnitude of the more massive black hole is bound to be <0.7 (at 90% probability). The luminosity distance to the source is 410+160−180 Mpc, corresponding to a redshift 0.09+0.03−0.04 assuming standard cosmology. The source location is constrained to an annulus section of 610 deg2, primarily in the southern hemisphere. The binary merges into a black hole of mass 62+4−4M⊙ and spin 0.67+0.05−0.07. This black hole is significantly more massive than any other inferred from electromagnetic observations in the stellar-mass regime