220 research outputs found
ASSOCIATION BETWEEN GRIP STRENGTH AND COGNITIVE FUNCTION AMONG COMMUNITY-DWELLING OLDER ADULTS.
GSA 2019 Annual Scientific MeetingPeer reviewe
LONGITUDINAL ASSOCIATION BETWEEN SERUM 25 HYDROXY VITAMIN D AND COGNITIVE FUNCTION AMONG ICELANDIC OLDER ADULTS.
GSA 2019 Annual Scientific MeetingPeer reviewe
Method for Assigning Priority Levels in Acute Care (MAPLe-AC) predicts outcomes of acute hospital care of older persons - a cross-national validation
To access publisher full text version of this article. Please click on the hyperlink in Additional Links field.BACKGROUND: Although numerous risk factors for adverse outcomes for older persons after an acute hospital stay have been : identified, a decision making tool combining all available information in a clinically meaningful way would be helpful for daily hospital practice. The purpose of this study was to evaluate the ability of the Method for Assigning Priority Levels for Acute Care (MAPLe-AC) to predict adverse outcomes in acute care for older people and to assess its usability as a decision making tool for discharge planning. METHODS: Data from a prospective multicenter study in five Nordic acute care hospitals with information from admission to a one year follow-up of older acute care patients were compared with a prospective study of acute care patients from admission to discharge in eight hospitals in Canada. The interRAI Acute Care assessment instrument (v1.1) was used for data collection. Data were collected during the first 24 hours in hospital, including pre-morbid and admission information, and at day 7 or at discharge, whichever came first. Based on this information a crosswalk was developed from the original MAPLe algorithm for home care settings to acute care (MAPLe-AC). The sample included persons 75 years or older who were admitted to acute internal medical services in one hospital in each of the five Nordic countries (n = 763) or to acute hospital care either internal medical or combined medical-surgical services in eight hospitals in Ontario, Canada (n = 393). The outcome measures considered were discharge to home, discharge to institution or death. Outcomes in a 1-year follow-up in the Nordic hospitals were: living at home, living in an institution or death, and survival. Logistic regression with ROC curves and Cox regression analyses were used in the analyses. RESULTS: Low and mild priority levels of MAPLe-AC predicted discharge home and high and very high priority levels predicted adverse outcome at discharge both in the Nordic and Canadian data sets, and one-year outcomes in the Nordic data set. The predictive accuracy (AUC's) of MAPLe-AC's was higher for discharge outcome than one year outcome, and for discharge home in Canadian hospitals but for adverse outcome in Nordic hospitals. High and very high priority levels in MAPLe-AC were also predictive of days to death adjusted for diagnoses in survival models. CONCLUSION: MAPLe-AC is a valid algorithm based on risk factors that predict outcomes of acute hospital care. It could be a helpful tool for early discharge planning although further testing for active use in clinical practice is still needed.Reykjavik Hospital Research Fund
St. Joseph's Research Fund, Iceland
Norwegian Medical Society
2
Diakonhjemmet Hospital
Diakonhjemmet University College
Diakonhjemmet Research Fund, Norway
Sweden's Lions Fund, Sweden
Health Transition Fund
Health Canada
Canadian Institutes for Health Research (CIHR)
Nordic Lions Red Feather Fund
Nordic Council of Ministers
Roikjer Fund, Denmark
Finnish Lions Fund, Finland
Icelandic Lions Fund
Memorial Fund of Helgu Jensdottur and SigurliĂ°a Kristjanssona
Reliability of the interRAI suite of assessment instruments: a 12-country study of an integrated health information system
<p>Abstract</p> <p>Background</p> <p>A multi-domain suite of instruments has been developed by the interRAI research collaborative to support assessment and care planning in mental health, aged care and disability services. Each assessment instrument comprises items common to other instruments and specialized items exclusive to that instrument. This study examined the reliability of the items from five instruments supporting home care, long term care, mental health, palliative care and post-acute care.</p> <p>Methods</p> <p>Paired assessments on 783 individuals across 12 nations were completed within 72 hours of each other by trained assessors who were blinded to the others' assessment. Reliability was tested using weighted kappa coefficients.</p> <p>Results</p> <p>The overall kappa mean value for 161 items which are common to 2 or more instruments was 0.75. The kappa mean value for specialized items varied among instruments from 0.63 to 0.73. Over 60% of items scored greater than 0.70.</p> <p>Conclusion</p> <p>The vast majority of items exceeded standard cut-offs for acceptable reliability, with only modest variation among instruments. The overall performance of these instruments showed that the interRAI suite has substantial reliability according to conventional cut-offs for interpreting the kappa statistic. The results indicate that interRAI items retain reliability when used across care settings, paving the way for cross domain application of the instruments as part of an integrated health information system.</p
Epidemiology and outcomes of people with dementia, delirium and unspecified cognitive impairment in the general hospital: prospective cohort study of 10,014 admissions
Background Cognitive impairment of various kinds is common in older people admitted to hospital, but previous research has usually focused on single conditions in highly-selected groups and has rarely examined associations with outcomes. This study examined prevalence and outcomes of cognitive impairment in a large unselected cohort of people aged 65+ with an emergency medical admission. Methods Between January 1, 2012, and June 30, 2013, admissions to a single general hospital acute medical unit aged 65+ underwent a structured specialist nurse assessment (n = 10,014). We defined ‘cognitive spectrum disorder’ (CSD) as any combination of delirium, known dementia, or Abbreviated Mental Test (AMT) score < 8/10. Routine data for length of stay (LOS), mortality, and readmission were linked to examine associations with outcomes. Results A CSD was present in 38.5% of all patients admitted aged over 65, and in more than half of those aged over 85. Overall, 16.7% of older people admitted had delirium alone, 7.9% delirium superimposed on known dementia, 9.4% known dementia alone, and 4.5% unspecified cognitive impairment (AMT score < 8/10, no delirium, no known dementia). Of those with known dementia, 45.8% had delirium superimposed. Outcomes were worse in those with CSD compared to those without – LOS 25.0 vs. 11.8 days, 30-day mortality 13.6% vs. 9.0%, 1-year mortality 40.0% vs. 26.0%, 1-year death or readmission 62.4% vs. 51.5% (allP < 0.01). There was relatively little difference by CSD type, although people with delirium superimposed on dementia had the longest LOS, and people with dementia the worst mortality at 1 year. Conclusions CSD is common in older inpatients and associated with considerably worse outcomes, with little variation between different types of CSD. Healthcare systems should systematically identify and develop care pathways for older people with CSD admitted as medical emergencies, and avoid only focusing on condition-specific pathways such as those for dementia or delirium alone
Azithromycin in the extremely low birth weight infant for the prevention of Bronchopulmonary Dysplasia: a pilot study
<p>Abstract</p> <p>Background</p> <p>Azithromycin reduces the severity of illness in patients with inflammatory lung disease such as cystic fibrosis and diffuse panbronchiolitis. Bronchopulmonary dysplasia (BPD) is a pulmonary disorder which causes significant morbidity and mortality in premature infants. BPD is pathologically characterized by inflammation, fibrosis and impaired alveolar development. The purpose of this study was to obtain pilot data on the effectiveness and safety of prophylactic azithromycin in reducing the incidence and severity of BPD in an extremely low birth weight (†1000 grams) population.</p> <p>Methods</p> <p>Infants †1000 g birth weight admitted to the University of Kentucky Neonatal Intensive Care Unit (level III, regional referral center) from 9/1/02-6/30/03 were eligible for this pilot study. The pilot study was double-blinded, randomized, and placebo-controlled. Infants were randomized to treatment or placebo within 12 hours of beginning mechanical ventilation (IMV) and within 72 hours of birth. The treatment group received azithromycin 10 mg/kg/day for 7 days followed by 5 mg/kg/day for the duration of the study. Azithromycin or placebo was continued until the infant no longer required IMV or supplemental oxygen, to a maximum of 6 weeks. Primary endpoints were incidence of BPD as defined by oxygen requirement at 36 weeks gestation, post-natal steroid use, days of IMV, and mortality. Data was analyzed by intention to treat using Chi-square and ANOVA.</p> <p>Results</p> <p>A total of 43 extremely premature infants were enrolled in this pilot study. Mean gestational age and birth weight were similar between groups. Mortality, incidence of BPD, days of IMV, and other morbidities were not significantly different between groups. Post-natal steroid use was significantly less in the treatment group [31% (6/19)] vs. placebo group [62% (10/16)] (p = 0.05). Duration of mechanical ventilation was significantly less in treatment survivors, with a median of 13 days (1â47 days) vs. 35 days (1â112 days)(p = 0.02).</p> <p>Conclusion</p> <p>Our study suggests that azithromycin prophylaxis in extremely low birth weight infants may effectively reduce post-natal steroid use for infants. Further studies are needed to assess the effects of azithromycin on the incidence of BPD and possible less common side effects, before any recommendations regarding routine clinical use can be made.</p
Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV
The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of âs = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pTâ„20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60â€pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2â€{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration
Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector
The inclusive and dijet production cross-sections have been measured for jets
containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass
energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The
measurements use data corresponding to an integrated luminosity of 34 pb^-1.
The b-jets are identified using either a lifetime-based method, where secondary
decay vertices of b-hadrons in jets are reconstructed using information from
the tracking detectors, or a muon-based method where the presence of a muon is
used to identify semileptonic decays of b-hadrons inside jets. The inclusive
b-jet cross-section is measured as a function of transverse momentum in the
range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet
cross-section is measured as a function of the dijet invariant mass in the
range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets
and the angular variable chi in two dijet mass regions. The results are
compared with next-to-leading-order QCD predictions. Good agreement is observed
between the measured cross-sections and the predictions obtained using POWHEG +
Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet
cross-section. However, it does not reproduce the measured inclusive
cross-section well, particularly for central b-jets with large transverse
momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final
version published in European Physical Journal
Development of quality indicators for monitoring outcomes of frail elderly hospitalised in acute care health settings: Study Protocol
Background: Frail older people admitted to acute care hospitals are at risk of a range of adverse outcomes, including geriatric syndromes, although targeted care strategies can improve health outcomes for these patients. It is therefore important to assess inter-hospital variation in performance in order to plan and resource improvement programs. Clinical quality outcome indicators provide a mechanism for identifying variation in performance over time and between hospitals, however to date there has been no routine use of such indicators in acute care settings. A barrier to using quality indicators is lack of access to routinely collected clinical data. The interRAI Acute Care (AC) assessment system supports comprehensive geriatric assessment of older people within routine daily practice in hospital and includes process and outcome data pertaining to geriatric syndromes. This paper reports the study protocol for the development of aged care quality indicators for acute care hospitals. Methods/Design. The study will be conducted in three phases:. 1. Development of a preliminary inclusive set of quality indicators set based on a literature review and expert panel consultation,. 2. A prospective field study including recruitment of 480 patients aged 70 years or older across 9 Australian hospitals. Each patient will be assessed on admission and discharge using the interRAI AC, and will undergo daily monitoring to observe outcomes. Medical records will be independently audited, and. 3. Analysis and compilation of a definitive quality indicator set, including two anonymous voting rounds for quality indicator inclusion by the expert panel. Discussion. The approach to quality indicators proposed in this protocol has four distinct advantages over previous efforts: the quality indicators focus on outcomes; they can be collected as part of a routinely applied clinical information and decision support system; the clinical data will be robust and will contribute to better understanding variations in hospital care of older patients; The quality indicators will have international relevance as they will be built on the interRAI assessment instrument, an internationally recognised clinical system
- âŠ