    Design of a fractional control using performance contours. Application to an electromechanical system

    Get PDF
    The article proposes a frequency-based method to design a controller ensuring dynamic behavior of a closed-loop control: the first overshoot of the step response in the tracking mode or in the regulation mode, the damping ratio and the natural frequency of its dominant oscillatory mode. This method uses two contours called “performance contours” and constructed on the Nichols diagram. The first contour is the common Nichols magnitude contour which can be considered as an iso-overshoot contour. The second contour, whose construction and analytic expression are given in this article, is a new contour defined on the Nichols diagram and parameterized by the damping ratio. The proposed method uses complex non-integer (or fractional) differentiation to compute a transfer function whose open-loop Nichols locus tangents both performance contours, thus ensuring stability margins (or stability degree). The method is applied to a DC motor whose speed is controlled

    Stability of closed-loop fractional-order systems and definition of damping contours for the design of controllers

    Get PDF
    Fractional complex order integrator has been used since 1991 for the design of robust control-systems. In the CRONE control methodology, it permits the parameterization of open loop transfer function which is optimized in a robustness context. Sets of fractional order integrators that lead to a given damping factor have also been used to build iso-damping contours on the Nichols plane. These iso-damping contours can also be used to optimize the third CRONE generation open-loop transfer function. However, these contours have been built using non band-limited integrators, even if such integrators reveal to lead to unstable closed loop systems. One objective of this paper is to show how the band-limitation modifies the left half-plane dominant poles of the closed loop system and removes the right half-plane ones. It is also presented how to obtain a fractional order open loop transfer function with a high phase slope and a useful frequency response. It is presented how the damping contours can be used to design robust controllers, not only CRONE controllers but also PD and QFT controllers

    Crone control of a nonlinear hydraulic actuator

    Get PDF
    The CRONE control (fractional robust control) of a hydraulic actuator whose dynamic model is nonlinear is presented. An input-output linearization under diffeomorphism and feedback is first achieved for the nominal plant. The relevance of this linearization when the parameters of the plant vary is then analyzed using the Volterra input-output representation in the frequency domain. CRONE control based on complex fractional differentiation is finally applied to control the velocity of the input-output linearized model when parametric variations occur

    Study of two robust controls for an hydraulic actuator

    Get PDF
    Two robust control design methodologies are analyzed and compared in this article: the H-infinity control system design and the CRONE control system design. The aim of this article is to give practical considerations that will help a designer to choose between these two methodologies. The example of an electrohydraulic actuator is given in order to evaluate the implementation of each methodology and to compare the final performance

    Input-output linearization and fractional robust control of a non-linear system

    Get PDF
    This article deals with the association of a linear robust controller and an input-output linearization feedback for the control of a perturbed and non-linear system. This technique is applied to the control of a hydraulic system whose actuator is non-linear and whose load is time-variant. The piston velocity of the actuator needs to be controlled and a pressure-difference inner-loop is used to improve the performance. To remove the effect of the non-linearity, an input-output linearization under diffeomorphism and feedback is achieved. CRONE control, based on complex fractional differentiation, is applied to design a controller for piston-velocity loop even when parametric variations occu

    Fractional robust control of ligthly damped systems

    Get PDF
    The article proposes a method to design a robust controller ensuring the damping ratio of a closed-loop control. The method uses a contour para-meterized by the damping ratio in the Nichols plane and the complex non-integer (or fractional)differentiation to compute a transfer function whose open-loop Nichols locus tangents this contour, thus ensuring dynamic performance. The proposed method is applied to a flexible structure (a clamped-free beam with piezoelectric ceramics). The aims of the control loop are to decrease the vibrations and to ensure the damping ratio of the controlled system

    A nyquist criterion for time-varying periodic systems, with application to a hydraulic test bench

    Get PDF
    In this paper, stability results dedicated to sampled periodic systems are applied to a mechanical system whose stiffness exhibits quick variations: a hydraulic test bench used to achieve mechanical test on complex structures. To carry out this application, time-varying w transformation representation of sampled periodic systems are first introduced. An extension of the Nyquist Criterion to sampled periodic systems is then given. Finally, this theorem is applied to evaluate the stability degree of the hydraulic test bench controlled using CRONE control methodology

    Fractional robust control with iso-damping property

    Get PDF
    This article deals with the problem of the reduction of structural vibrations with isodamping property. The proposed methodology is based on: - a contour defined in the Nichols plane and significant of the damping ratio of the closed-loop response - a robust control method that uses fractional order integration. The methodology is applied to an aircraft wing model made with a beam and a tank whose different levels of fillings are considered as uncertainties

    Robust Control System Design for Multivariable Plants with Lightly Damped Modes

    Get PDF
    International audienceA robust controller design is proposed for the active suspension system benchmark problem. The CRONE control system design used is extended to unstable multivariable plants with lightly damped modes and RHP zeros. Decoupling and stabilizing controller K, is achieved for the open-loop transfer matrix. Fractional order transfer functions are used to define all the components of the diagonal open-loop transfer matrix, ÎČ. In defining the fractional open-loop transfer function ÎČ 0i some elements of the plants, G0 and its inverse must be considered to achieve the stable controller. Optimisation provides the best fractional open-loop ÎČopt. Finally, frequency domain system identification is used to find controller K=G0-1 ÎČopt

    On the Selection of Tuning Methodology of FOPID Controllers for the Control of Higher Order Processes

    Get PDF
    In this paper, a comparative study is done on the time and frequency domain tuning strategies for fractional order (FO) PID controllers to handle higher order processes. A new fractional order template for reduced parameter modeling of stable minimum/non-minimum phase higher order processes is introduced and its advantage in frequency domain tuning of FOPID controllers is also presented. The time domain optimal tuning of FOPID controllers have also been carried out to handle these higher order processes by performing optimization with various integral performance indices. The paper highlights on the practical control system implementation issues like flexibility of online autotuning, reduced control signal and actuator size, capability of measurement noise filtration, load disturbance suppression, robustness against parameter uncertainties etc. in light of the above tuning methodologies.Comment: 27 pages, 10 figure
    • 