    Central model predictive control of a group of domestic heat pumps, case study for a small district

    Get PDF
    In this paper we investigate optimal control of a group of heat pumps. Each heat pump provides space heating and domestic hot water to a single household. Besides a heat pump, each house has a buffer for domestic hot water and a floor heating system for space heating. The paper describes models and algorithms used for the prediction and planning steps in order to obtain a planning for the heat pumps. The optimization algorithm minimizes the maximum peak electricity demand of the district. Simulated results demonstrate the resulting aggregated electricity demand, the obtained thermal comfort and the state of charge of the domestic hot water storage for an example house. Our results show that a model predictive control outperforms conventional control of individual heat pumps based on feedback control principles

    A comprehensive model for battery State of Charge prediction

    Get PDF
    In this paper the relatively simple model for State of Charge prediction, based on energy conservation, introduced in [1] is improved and verified. The model as introduced in [1] is verified for Pb-acid, Li-ion and Seasalt batteries. The model is further improved to accommodate the rate capacity effect and the capacity recovery effect, the improvements are verified with lead-acid batteries. For further verification the model is applied on a realistic situation and compared to measurements on the behavior of a real battery in that situation. Furthermore the results are compared to results of the well-established KiBaM model. Predictions on the SoC over time done using the proposed model closely follow the SoC over time calculated from measured data. The resulting improved model is both simple and effective, making it specially useful as part of smart control, and energy usage simulations

    Author Correction: Cross-ancestry genome-wide association analysis of corneal thickness strengthens link between complex and Mendelian eye diseases.

    Get PDF
    Emmanuelle Souzeau, who contributed to analysis of data, was inadvertently omitted from the author list in the originally published version of this Article. This has now been corrected in both the PDF and HTML versions of the Article

    Cross-ancestry genome-wide association analysis of corneal thickness strengthens link between complex and Mendelian eye diseases.

    Get PDF
    Central corneal thickness (CCT) is a highly heritable trait associated with complex eye diseases such as keratoconus and glaucoma. We perform a genome-wide association meta-analysis of CCT and identify 19 novel regions. In addition to adding support for known connective tissue-related pathways, pathway analyses uncover previously unreported gene sets. Remarkably, >20% of the CCT-loci are near or within Mendelian disorder genes. These included FBN1, ADAMTS2 and TGFB2 which associate with connective tissue disorders (Marfan, Ehlers-Danlos and Loeys-Dietz syndromes), and the LUM-DCN-KERA gene complex involved in myopia, corneal dystrophies and cornea plana. Using index CCT-increasing variants, we find a significant inverse correlation in effect sizes between CCT and keratoconus (r = -0.62, P = 5.30 × 10-5) but not between CCT and primary open-angle glaucoma (r = -0.17, P = 0.2). Our findings provide evidence for shared genetic influences between CCT and keratoconus, and implicate candidate genes acting in collagen and extracellular matrix regulation

    Cross-ancestry genome-wide association analysis of corneal thickness strengthens link between complex and Mendelian eye diseases

    Get PDF
    Central corneal thickness (CCT) is a highly heritable trait associated with complex eye diseases such as keratoconus and glaucoma. We perform a genome-wide association meta-analysis of CCT and identify 19 novel regions. In addition to adding support for known connective tissue-related pathways, pathway analyses uncover previously unreported gene sets. Remarkably, >20% of the CCT-loci are near or within Mendelian disorder genes. These included FBN1, ADAMTS2 and TGFB2 which associate with connective tissue disorders (Marfan, Ehlers-Danlos and Loeys-Dietz syndromes), and the LUM-DCN-KERA gene complex involved in myopia, corneal dystrophies and cornea plana. Using index CCT-increasing variants, we find a significant inverse correlation in effect sizes between CCT and keratoconus (r =-0.62, P = 5.30 × 10-5) but not between CCT and primary open-angle glaucoma (r =-0.17, P = 0.2). Our findings provide evidence for shared genetic influences between CCT and keratoconus, and implicate candidate genes acting in collagen and extracellular matrix regulation

    Multi-trait genome-wide association study identifies new loci associated with optic disc parameters.

    Get PDF
    Funder: All funders per study are acknowledged in the Supplementary FileA new avenue of mining published genome-wide association studies includes the joint analysis of related traits. The power of this approach depends on the genetic correlation of traits, which reflects the number of pleiotropic loci, i.e. genetic loci influencing multiple traits. Here, we applied new meta-analyses of optic nerve head (ONH) related traits implicated in primary open-angle glaucoma (POAG); intraocular pressure and central corneal thickness using Haplotype reference consortium imputations. We performed a multi-trait analysis of ONH parameters cup area, disc area and vertical cup-disc ratio. We uncover new variants; rs11158547 in PPP1R36-PLEKHG3 and rs1028727 near SERPINE3 at genome-wide significance that replicate in independent Asian cohorts imputed to 1000 Genomes. At this point, validation of these variants in POAG cohorts is hampered by the high degree of heterogeneity. Our results show that multi-trait analysis is a valid approach to identify novel pleiotropic variants for ONH

    Multi-trait genome-wide association study identifies new loci associated with optic disc parameters

    Get PDF
    A new avenue of mining published genome-wide association studies includes the joint analysis of related traits. The power of this approach depends on the genetic correlation of traits, which reflects the number of pleiotropic loci, i.e. genetic loci influencing multiple traits. Here, we applied new meta-analyses of optic nerve head (ONH) related traits implicated in primary open-angle glaucoma (POAG); intraocular pressure and central corneal thickness using Haplotype reference consortium imputations. We performed a multi-trait analysis of ONH parameters cup area, disc area and vertical cup-disc ratio. We uncover new variants; rs11158547 in PPP1R36-PLEKHG3 and rs1028727 near SERPINE3 at genome-wide significance that replicate in independent Asian cohorts imputed to 1000 Genomes. At this point, validation of these variants in POAG cohorts is hampered by the high degree of heterogeneity. Our results show that multi-trait analysis is a valid approach to identify novel pleiotropic variants for ONH

    Towards 100% renewable energy supply for urban areas and the role of smart control

    Get PDF

    A Real-Time Stereo SmartCam, using FPGA, SIMD and VLIW

    No full text
    Abstract. This paper describes the architecture of a SmartCamera, applied for real-time dense stereo vision. The system is based on two TriMedia SmartCameras, an FPGA for low level image pre- and postprocessing, a single chip SIMD array for disparity calculation for all epipolar lines in parallel, and a VLIW processor for further processing of the image processing applications at hand. The FPGA is the heart of the system, its architecture is a synchronous ring with time interleaved dataslots, enabling virtually parallel image channels. We have simplified the development of image processing functions by creating libraries and an automated compile flow, allowing easy debugging and coefficient tweaking of the functions and run-time controllability for a per-frame image processing sub-task schedular. We have implemented a dense stereo vision algorithm on the platform and measured a 40x processing speedup compared to the same implementation on an existing SmartCamera