77 research outputs found

    Search for Lorentz and CPT violation using sidereal time dependence of neutrino flavor transitions over a short baseline

    Get PDF
    A class of extensions of the Standard Model allows Lorentz and CPT violations, which can be identified by the observation of sidereal modulations in the neutrino interaction rate. A search for such modulations was performed using the T2K on-axis near detector. Two complementary methods were used in this study, both of which resulted in no evidence of a signal. Limits on associated Lorentz and CPT-violating terms from the Standard Model extension have been derived by taking into account their correlations in this model for the first time. These results imply such symmetry violations are suppressed by a factor of more than 10 20 at the GeV scale

    On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection

    Get PDF
    A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)

    Measurement of coherent π+π^{+} production in low energy neutrino-Carbon scattering

    Get PDF
    We report the first measurement of the flux-averaged cross section for charged current coherent π+\pi^{+} production on carbon for neutrino energies less than 1.5 GeV to a restricted final state phase space region in the T2K near detector, ND280. Comparisons are made with predictions from the Rein-Sehgal coherent production model and the model by Alvarez-Ruso {\it et al.}, the latter representing the first implementation of an instance of the new class of microscopic coherent models in a neutrino interaction Monte Carlo event generator. This results contradicts the null results reported by K2K and SciBooNE in a similar neutrino energy region

    Methoxyflurane as an Analgesic for Prehospital Use at High Altitude

    No full text

    The T2K experiment

    Get PDF
    The T2K experiment is a long baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ13 by observing νe appearance in a νμ beam. It also aims to make a precision measurement of the known oscillation parameters, and sin22θ23, via νμ disappearance studies. Other goals of the experiment include various neutrino cross-section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem

    A national survey of the provision of ultrasound surveillance for the detection of hepatocellular carcinoma

    No full text
    Objective Hepatocellular carcinoma (HCC), the sixth most common cancer worldwide and third most common cause of cancer related death, is closely associated with the presence of cirrhosis. Survival is determined by the stage of the cancer, with asymptomatic small tumours being more amenable to treatment. Early diagnosis is dependent on regular surveillance and the primary objective of this survey was to gain a better understanding of the baseline attitudes towards and provision of ultrasound surveillance (USS) HCC surveillance in the UK. In addition, information was obtained on the stages of cancer of the patients being referred to and discussed at regional multidisciplinary team meetings.Design UK hepatologists, gastroenterologists and nurse specialists were sent a questionnaire survey regarding the provision of USS for detection of HCC in their respective hospitals.Results Provision of surveillance was poor overall, with many hospitals lacking the necessary mechanisms to make abnormal results, if detected, known to referring clinicians. There was also a lack of standard data collection and in many hospitals basic information on the number of patients with cirrhosis and how many were developing HCC was not known. For the majority of new HCC cases was currently being made only at an incurable late stage (60%).Conclusions In the UK, the current provision of USS based HCC surveillance is poor and needs to be upgraded urgently
    corecore