2,159 research outputs found
Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience
AIMS: To evaluate the accuracy of low-dose computed tomography coronary angiography (CTCA) using prospective ECG-triggering for the assessment of coronary artery disease (CAD). METHODS AND RESULTS: A total of 30 patients (19 males, 11 females, mean age 58.8 +/- 9.9 years) underwent low-dose CTCA and invasive coronary angiography (CA) [median 2 days (0, 41)]. Before CT scanning, intravenous beta-blocker was administered in 18 of 30 patients as heart rate (HR) was >65 b.p.m., achieving a mean HR of 55.7 +/- 7.9 b.p.m. CAD was defined as coronary artery narrowing > or =50%, using CA as standard of reference. The estimated mean effective radiation dose was 2.1 +/- 0.7 mSv (range: 1.0-3.3), yielding 96.0% (383/399) of evaluable segments. On an intention-to-diagnose-base, all non-evaluative segments were included in the analysis. Vessels with a non-evaluative segment and no further finding were censored as false positive. Patient-based analysis revealed sensitivity, specificity, positive predictive value, and negative predictive value of 100, 83.3, 90.0, and 100%, respectively. The respective values per vessel were 100, 88.9, 85.7, and 100%, respectively. CONCLUSION: Prospective ECG-triggering allows low-dose CTCA and provides high diagnostic accuracy in the assessment of CAD in patients with stable sinus rhythm and a low heart rat
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
AIMS: To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). METHODS AND RESULTS: Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P 63 b.p.m. (P < 0.001). CONCLUSION: This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
AIMS: To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). METHODS AND RESULTS: Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P 63 b.p.m. (P < 0.001). CONCLUSION: This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.
Photonic band-gap effects on photoluminescence of silicon nanocrystals embedded in artificial opals
Si nanocrystals were formed in synthetic opals by Si-ion implantation and their optical properties studied using microphotoluminescence and reflection techniques. The properties of areas with high crystalline quality are compared with those of disordered regions of samples. The photoluminescencespectrum from Si nanocrystals embedded in silica spheres is narrowed by the inhibition of emission at wavelengths corresponding to the opalphotonic pseudoband gap (∼690 nm). Measurements of photoluminescencespectra from individual implanted silica spheres is also demonstrated and the number of emitting Si nanocrystals in single brightly emitting spheres is estimated to be of the order of one thousand.This work was supported by GACR (202/03/0789),
NATO (PST.CLG.978100), and by the Royal Swedish Academy
of Sciences. One of the authors ~J.V.! appreciates financial
support from the French government (program
Echange)
Present Status and Future Programs of the n_TOF Experiment
This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial License 3.0, which permits unrestricted use, distribution, and reproduction in any noncommercial medium, provided the original work is properly citedThe neutron time-of-flight facility n_TOF at CERN, Switzerland, operational since 2001, delivers neutrons using the Proton Synchrotron (PS) 20 GeV/c proton beam impinging on a lead spallation target. The facility combines a very high instantaneous neutron flux, an excellent time of flight resolution due to the distance between the experimental area and the production target (185 meters), a low intrinsic background and a wide range of neutron energies, from thermal to GeV neutrons. These characteristics provide a unique possibility to perform neutron-induced capture and fission cross-section measurements for applications in nuclear astrophysics and in nuclear reactor technology.The most relevant measurements performed up to now and foreseen for the future will be presented in this contribution. The overall efficiency of the experimental program and the range of possible measurements achievable with the construction of a second experimental area (EAR-2), vertically located 20 m on top of the n_TOF spallation target, might offer a substantial improvement in measurement sensitivities. A feasibility study of the possible realisation of the installation extension will be also presented
The nucleosynthesis of heavy elements in Stars : The key isotope 25Mg
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 2.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly citedWe have measured the radiative neutron-capture cross section and the total neutron-induced cross section of one of the most important isotopes for the s process, the 25Mg. The measurements have been carried out at the neutron time-of-flight facilities n-TOF at CERN (Switzerland) and GELINA installed at the EC-JRC-IRMM (Belgium). The cross sections as a function of neutron energy have been measured up to approximately 300 keV, covering the energy region of interest to the s process. The data analysis is ongoing and preliminary results show the potential relevance for the s process.Peer reviewe
238U(n, γ) reaction cross section measurement with C 6D6 detectors at the n-TOF CERN facility
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 2.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly citedThe radiative capture cross section of 238U is very important for the developing of new reactor technologies and the safety of existing ones. Here the preliminary results of the 238U(n,γ) cross section measurement performed at n-TOF with C6D6 scintillation detectors are presented, paying particular attention to data reduction and background subtraction.Peer reviewe
Towards the high-accuracy determination of the 238U fission cross section at the threshold region at CERN - N-TOF
The 238U fission cross section is an international standard beyond 2 MeV where the fission plateau starts. However, due to its importance in fission reactors, this cross-section should be very accurately known also in the threshold region below 2 MeV. The 238U fission cross section has been measured relative to the 235U fission cross section at CERN - n-TOF with different detection systems. These datasets have been collected and suitably combined to increase the counting statistics in the threshold region from about 300 keV up to 3 MeV. The results are compared with other experimental data, evaluated libraries, and the IAEA standards
High accuracy 234U(n,f) cross section in the resonance energy region
New results are presented of the 234U neutron-induced fission cross section, obtained with high accuracy in the resonance region by means of two methods using the 235U(n,f) as reference. The recent evaluation of the 235U(n,f) obtained with SAMMY by L. C. Leal et al. (these Proceedings), based on previous n-TOF data [1], has been used to calculate the 234U(n,f) cross section through the 234U/235U ratio, being here compared with the results obtained by using the n-TOF neutron flux
Neutron cross-sections for advanced nuclear systems : The n-TOF project at CERN
© Owned by the authors, published by EDP Sciences, 2014 This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly citedThe study of neutron-induced reactions is of high relevance in a wide variety of fields, ranging from stellar nucleosynthesis and fundamental nuclear physics to applications of nuclear technology. In nuclear energy, high accuracy neutron data are needed for the development of Generation IV fast reactors and accelerator driven systems, these last aimed specifically at nuclear waste incineration, as well as for research on innovative fuel cycles. In this context, a high luminosity Neutron Time Of Flight facility, n-TOF, is operating at CERN since more than a decade, with the aim of providing new, high accuracy and high resolution neutron cross-sections. Thanks to the features of the neutron beam, a rich experimental program relevant to nuclear technology has been carried out so far. The program will be further expanded in the near future, thanks in particular to a new high-flux experimental area, now under construction.Peer reviewedFinal Published versio
- …