205 research outputs found
MPGD's spatial and energy resolution studies with an adjustable point-like electron source
11th Vienna Conference on Instrumentation (February 2007) , to appear in the Proceedings (NIM A)International audienceMicropattern Gaseous Detectors (MPGD), like Micromegas or GEM, are used or foreseen in particle physics experiments for which a very good spatial resolution is required. We have developed an experimental method to separate the contribution of the transverse diffusion and the multiplication process by varying the number of primary electrons generated by a point-like source. A pulsed nitrogen laser is focused by an optical set-up on the drift electrode which is made of a thin metal layer deposited on a quartz lamina. The number of primary electrons can be adjusted from a few to several thousands on a spot which transverse size is less than RMS. The detector can be positioned with an accuracy of by a motorized three dimensional system. This method was applied to a small Micromegas detector with a gain set between and and an injection of 60 to 2000 photoelectrons. Spatial resolutions as small as were measured with 2000 primary electrons. An estimation of the upper limit of the relative gain variance can be obtained from the measurements
A large dynamic range integrated front-end for photomultiplier tubes
A full custom analog CMOS circuit for obtaining a photomultiplier readout with a 16 bit resolution over 7 V has been developed. It is part of the R&D program for the photomultiplier tube front-end readout of the Pierre Auger Observatory northern site. It performs signal duplication and amplification with three gains: 0.15, 1 and 6. Each amplifier has a resolution of 10 bit and can measure signals with durations of several microseconds with a good baseline stability, for an input charge of up to tens of nano-Coulombs. The amplification is performed by current feedback amplifiers with a bandwidth of 60 MHz.The input impedance, adapted to the coaxial cables, is stable over the whole working range. A prototype was submitted in April 2004 and successfully tested. The linearity over the working range is less than 1%. It was also successfully tested on the Auger surface detector element installed at Orsay (comprised of a Cherenkov water tank equipped with Photonis XP1805 9” diameter photomultiplier tubes). The resolution over 7 V is 16.6 bit.This circuit is the first step towards a “system-on-a-chip” (SoC) solution for a photomultplier tube readout equipped with a fast ADC for signal digitization. A setup using a single cable for both the signal and the photomultiplier high voltage power supply was shown to be successful
Recommended from our members
Making the transition to services in the animal health industry
The objective of this paper is to explore the steps and practices involved in the management of the shift to services in the context of the animal health industry. Research was carried on a leading animal health company, comparing and contrasting the transition to services between two of its most important regions. The research demonstrates that the delivery journey of the sales force lies at the core of the service transition, and it has expanded the servitization theory by unfolding the two fundamental processes that organizations experience in the transition to services. These are: the service development strategy; and the sales force delivery. This is the first research to explain the changes in “the sales force delivery” process in selling services as opposed to products. The best practices required to make the shift to services include leveraging customers’ experience, implementing service value and benefits, and building an integrated service team
The HADES Tracking System
The tracking system of the dielectron spectrometer HADES at GSI Darmstadt is
formed out of 24 low-mass, trapezoidal multi-layer drift chambers providing in
total about 30 square meter of active area. Low multiple scattering in the in
total four planes of drift chambers before and after the magnetic field is
ensured by using helium-based gas mixtures and aluminum cathode and field
wires. First in-beam performance results are contrasted with expectations from
simulations. Emphasis is placed on the energy loss information, exploring its
relevance regarding track recognition.Comment: 6 pages, 4 figures, presented at the 10th Vienna Conference on
Instrumentation, Vienna, February 2004, to be published in NIM A (special
issue
Measurements of sideward flow around the balance energy
Sideward flow values have been determined with the INDRA multidetector for
Ar+Ni, Ni+Ni and Xe+Sn systems studied at GANIL in the 30 to 100 A.MeV incident
energy range. The balance energies found for Ar+Ni and Ni+Ni systems are in
agreement with previous experimental results and theoretical calculations.
Negative sideward flow values have been measured. The possible origins of such
negative values are discussed. They could result from a more important
contribution of evaporated particles with respect to the contribution of
promptly emitted particles at mid-rapidity. But effects induced by the methods
used to reconstruct the reaction plane cannot be totally excluded. Complete
tests of these methods are presented and the origins of the
``auto-correlation'' effect have been traced back. For heavy fragments, the
observed negative flow values seem to be mainly due to the reaction plane
reconstruction methods. For light charged particles, these negative values
could result from the dynamics of the collisions and from the reaction plane
reconstruction methods as well. These effects have to be taken into account
when comparisons with theoretical calculations are done.Comment: 27 pages, 15 figure
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
This document is the Technical Design Report covering the two large
spectrometer magnets of the PANDA detector set-up. It shows the conceptual
design of the magnets and their anticipated performance. It precedes the tender
and procurement of the magnets and, hence, is subject to possible modifications
arising during this process.Comment: 10 pages, 14MB, accepted by FAIR STI in May 2009, editors: Inti
Lehmann (chair), Andrea Bersani, Yuri Lobanov, Jost Luehning, Jerzy Smyrski,
Technical Coordiantor: Lars Schmitt, Bernd Lewandowski (deputy),
Spokespersons: Ulrich Wiedner, Paola Gianotti (deputy
Single electron response and energy resolution of a Micromegas detector
Micro-Pattern Gaseous Detectors (MPGDs) such as Micromegas or GEM are used in
particle physics experiments for their capabilities in particle tracking at
high rates. Their excellent position resolutions are well known but their
energy characteristics have been less studied. The energy resolution is mainly
affected by the ionisation processes and detector gain fluctuations. This paper
presents a method to separetely measure those two contributions to the energy
resolution of a Micromegas detector. The method relies on the injection of a
controlled number of electrons. The Micromegas has a 1.6-mm drift zone and a
160-m amplification gap. It is operated in Ne
95%-iCH 5% at atmospheric pressure. The electrons
are generated by non-linear photoelectric emission issued from the photons of a
pulsed 337-nm wavelength laser coupled to a focusing system. The single
electron response has been measured at different gains (3.7 10,
5.0 10 and 7.0 10) and is fitted with a good
agreement by a Polya distribution. From those fits, a relative gain variance of
0.310.02 is deduced. The setup has also been characterised at several
voltages by fitting the energy resolution measured as a function of the number
of primary electrons, ranging from 5 up to 210. A maximum value of the Fano
factor (0.37) has been estimated for a 5.9 keV X-rays interacting in the Ne
95%-iCH 5% gas mixture.Comment: Preprint submitted to Nuclear Instrumentation and Methods in Physics
Research Section A: Accelerators, Spectrometers, Detectors and Associated
Equipment; Nuclear Instruments and Methods in Physics Research Section A:
Accelerators, Spectrometers, Detectors and Associated Equipment in press
(2009
Mass and charge identification of fragments detected with the Chimera Silicon-CsI(Tl) telescopes
Mass and charge identification of charged products detected with
Silicon-CsI(Tl) telescopes of the Chimera apparatus is presented. An
identification function, based on the Bethe-Bloch formula, is used to fit
empirical correlation between Delta E and E ADC readings, in order to
determine, event by event, the atomic and mass numbers of the detected charged
reaction products prior to energy calibration.Comment: 24 pages, 7 .jpg figures, submitted to Nucl.Instr.
The High-Acceptance Dielectron Spectrometer HADES
HADES is a versatile magnetic spectrometer aimed at studying dielectron
production in pion, proton and heavy-ion induced collisions. Its main features
include a ring imaging gas Cherenkov detector for electron-hadron
discrimination, a tracking system consisting of a set of 6 superconducting
coils producing a toroidal field and drift chambers and a multiplicity and
electron trigger array for additional electron-hadron discrimination and event
characterization. A two-stage trigger system enhances events containing
electrons. The physics program is focused on the investigation of hadron
properties in nuclei and in the hot and dense hadronic matter. The detector
system is characterized by an 85% azimuthal coverage over a polar angle
interval from 18 to 85 degree, a single electron efficiency of 50% and a vector
meson mass resolution of 2.5%. Identification of pions, kaons and protons is
achieved combining time-of-flight and energy loss measurements over a large
momentum range. This paper describes the main features and the performance of
the detector system
Neural Substrates of Mounting Temporal Expectation
A cognitive and neuroanatomical perspective on how timing and expectation are represented in the human brain
- …