205 research outputs found

    MPGD's spatial and energy resolution studies with an adjustable point-like electron source

    No full text
    11th Vienna Conference on Instrumentation (February 2007) , to appear in the Proceedings (NIM A)International audienceMicropattern Gaseous Detectors (MPGD), like Micromegas or GEM, are used or foreseen in particle physics experiments for which a very good spatial resolution is required. We have developed an experimental method to separate the contribution of the transverse diffusion and the multiplication process by varying the number of primary electrons generated by a point-like source. A pulsed nitrogen laser is focused by an optical set-up on the drift electrode which is made of a thin metal layer deposited on a quartz lamina. The number of primary electrons can be adjusted from a few to several thousands on a spot which transverse size is less than 100μm100 \mu m RMS. The detector can be positioned with an accuracy of 1μm1\mu m by a motorized three dimensional system. This method was applied to a small Micromegas detector with a gain set between 10310^3 and 2.1042.10^4 and an injection of 60 to 2000 photoelectrons. Spatial resolutions as small as 5μm5\mu m were measured with 2000 primary electrons. An estimation of the upper limit of the relative gain variance can be obtained from the measurements

    A large dynamic range integrated front-end for photomultiplier tubes

    No full text
    A full custom analog CMOS circuit for obtaining a photomultiplier readout with a 16 bit resolution over 7 V has been developed. It is part of the R&D program for the photomultiplier tube front-end readout of the Pierre Auger Observatory northern site. It performs signal duplication and amplification with three gains: 0.15, 1 and 6. Each amplifier has a resolution of 10 bit and can measure signals with durations of several microseconds with a good baseline stability, for an input charge of up to tens of nano-Coulombs. The amplification is performed by current feedback amplifiers with a bandwidth of 60 MHz.The input impedance, adapted to the coaxial cables, is stable over the whole working range. A prototype was submitted in April 2004 and successfully tested. The linearity over the working range is less than 1%. It was also successfully tested on the Auger surface detector element installed at Orsay (comprised of a Cherenkov water tank equipped with Photonis XP1805 9” diameter photomultiplier tubes). The resolution over 7 V is 16.6 bit.This circuit is the first step towards a “system-on-a-chip” (SoC) solution for a photomultplier tube readout equipped with a fast ADC for signal digitization. A setup using a single cable for both the signal and the photomultiplier high voltage power supply was shown to be successful

    The HADES Tracking System

    Full text link
    The tracking system of the dielectron spectrometer HADES at GSI Darmstadt is formed out of 24 low-mass, trapezoidal multi-layer drift chambers providing in total about 30 square meter of active area. Low multiple scattering in the in total four planes of drift chambers before and after the magnetic field is ensured by using helium-based gas mixtures and aluminum cathode and field wires. First in-beam performance results are contrasted with expectations from simulations. Emphasis is placed on the energy loss information, exploring its relevance regarding track recognition.Comment: 6 pages, 4 figures, presented at the 10th Vienna Conference on Instrumentation, Vienna, February 2004, to be published in NIM A (special issue

    Measurements of sideward flow around the balance energy

    Full text link
    Sideward flow values have been determined with the INDRA multidetector for Ar+Ni, Ni+Ni and Xe+Sn systems studied at GANIL in the 30 to 100 A.MeV incident energy range. The balance energies found for Ar+Ni and Ni+Ni systems are in agreement with previous experimental results and theoretical calculations. Negative sideward flow values have been measured. The possible origins of such negative values are discussed. They could result from a more important contribution of evaporated particles with respect to the contribution of promptly emitted particles at mid-rapidity. But effects induced by the methods used to reconstruct the reaction plane cannot be totally excluded. Complete tests of these methods are presented and the origins of the ``auto-correlation'' effect have been traced back. For heavy fragments, the observed negative flow values seem to be mainly due to the reaction plane reconstruction methods. For light charged particles, these negative values could result from the dynamics of the collisions and from the reaction plane reconstruction methods as well. These effects have to be taken into account when comparisons with theoretical calculations are done.Comment: 27 pages, 15 figure

    Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets

    Full text link
    This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.Comment: 10 pages, 14MB, accepted by FAIR STI in May 2009, editors: Inti Lehmann (chair), Andrea Bersani, Yuri Lobanov, Jost Luehning, Jerzy Smyrski, Technical Coordiantor: Lars Schmitt, Bernd Lewandowski (deputy), Spokespersons: Ulrich Wiedner, Paola Gianotti (deputy

    Single electron response and energy resolution of a Micromegas detector

    Full text link
    Micro-Pattern Gaseous Detectors (MPGDs) such as Micromegas or GEM are used in particle physics experiments for their capabilities in particle tracking at high rates. Their excellent position resolutions are well known but their energy characteristics have been less studied. The energy resolution is mainly affected by the ionisation processes and detector gain fluctuations. This paper presents a method to separetely measure those two contributions to the energy resolution of a Micromegas detector. The method relies on the injection of a controlled number of electrons. The Micromegas has a 1.6-mm drift zone and a 160-μ\mum amplification gap. It is operated in Ne 95%-iC4\mathrm{_4}H10\mathrm{_{10}} 5% at atmospheric pressure. The electrons are generated by non-linear photoelectric emission issued from the photons of a pulsed 337-nm wavelength laser coupled to a focusing system. The single electron response has been measured at different gains (3.7 104\mathrm{^4}, 5.0 104\mathrm{^4} and 7.0 104\mathrm{^4}) and is fitted with a good agreement by a Polya distribution. From those fits, a relative gain variance of 0.31±\pm0.02 is deduced. The setup has also been characterised at several voltages by fitting the energy resolution measured as a function of the number of primary electrons, ranging from 5 up to 210. A maximum value of the Fano factor (0.37) has been estimated for a 5.9 keV X-rays interacting in the Ne 95%-iC4\mathrm{_4}H10\mathrm{_{10}} 5% gas mixture.Comment: Preprint submitted to Nuclear Instrumentation and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment; Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment in press (2009

    Mass and charge identification of fragments detected with the Chimera Silicon-CsI(Tl) telescopes

    Full text link
    Mass and charge identification of charged products detected with Silicon-CsI(Tl) telescopes of the Chimera apparatus is presented. An identification function, based on the Bethe-Bloch formula, is used to fit empirical correlation between Delta E and E ADC readings, in order to determine, event by event, the atomic and mass numbers of the detected charged reaction products prior to energy calibration.Comment: 24 pages, 7 .jpg figures, submitted to Nucl.Instr.

    The High-Acceptance Dielectron Spectrometer HADES

    Get PDF
    HADES is a versatile magnetic spectrometer aimed at studying dielectron production in pion, proton and heavy-ion induced collisions. Its main features include a ring imaging gas Cherenkov detector for electron-hadron discrimination, a tracking system consisting of a set of 6 superconducting coils producing a toroidal field and drift chambers and a multiplicity and electron trigger array for additional electron-hadron discrimination and event characterization. A two-stage trigger system enhances events containing electrons. The physics program is focused on the investigation of hadron properties in nuclei and in the hot and dense hadronic matter. The detector system is characterized by an 85% azimuthal coverage over a polar angle interval from 18 to 85 degree, a single electron efficiency of 50% and a vector meson mass resolution of 2.5%. Identification of pions, kaons and protons is achieved combining time-of-flight and energy loss measurements over a large momentum range. This paper describes the main features and the performance of the detector system
    corecore