487 research outputs found
Health related quality of life in adolescents with idiopathic scoliosis: a cross-cultural comparison between two methods of treatment
he present study aims at evaluating the effects produced
on HRQOL by two different methods of physiotherapy in
adolescent population with Idiopathic Scoliosis (IS): SEAS,
used in Milan (Italia) in ISICO center, and Barcelona Scoliosis
Physical Therapy School, in E. Salvá Institut (Spain)
Large-angle production of charged pions by 3 GeV/c - 12 GeV/c protons on carbon, copper and tin targets
A measurement of the double-differential production cross-section
in proton--carbon, proton--copper and proton--tin collisions in the range of
pion momentum 100 \MeVc \leq p < 800 \MeVc and angle 0.35 \rad \le \theta
<2.15 \rad is presented. The data were taken with the HARP detector in the T9
beam line of the CERN PS. The pions were produced by proton beams in a momentum
range from 3 \GeVc to 12 \GeVc hitting a target with a thickness of 5% of a
nuclear interaction length. The tracking and identification of the produced
particles was done using a small-radius cylindrical time projection chamber
(TPC) placed in a solenoidal magnet. An elaborate system of detectors in the
beam line ensured the identification of the incident particles. Results are
shown for the double-differential cross-sections at four incident proton beam
momenta (3 \GeVc, 5 \GeVc, 8 \GeVc and 12 \GeVc)
Comparison of large-angle production of charged pions with incident protons on cylindrical long and short targets
The HARP collaboration has presented measurements of the double-differential
pi+/pi- production cross-section in the range of momentum 100 MeV/c <= p 800
MeV/c and angle 0.35 rad <= theta <= 2.15 rad with proton beams hitting thin
nuclear targets. In many applications the extrapolation to long targets is
necessary. In this paper the analysis of data taken with long (one interaction
length) solid cylindrical targets made of carbon, tantalum and lead is
presented. The data were taken with the large acceptance HARP detector in the
T9 beam line of the CERN PS. The secondary pions were produced by beams of
protons with momenta 5 GeV/c, 8 GeV/c and 12 GeV/c. The tracking and
identification of the produced particles were performed using a small-radius
cylindrical time projection chamber (TPC) placed inside a solenoidal magnet.
Incident protons were identified by an elaborate system of beam detectors.
Results are obtained for the double-differential yields per target nucleon d2
sigma / dp dtheta. The measurements are compared with predictions of the MARS
and GEANT4 Monte Carlo simulations.Comment: 43 pages, 20 figure
Absolute Momentum Calibration of the HARP TPC
In the HARP experiment the large-angle spectrometer is using a cylindrical
TPC as main tracking and particle identification detector. The momentum scale
of reconstructed tracks in the TPC is the most important systematic error for
the majority of kinematic bins used for the HARP measurements of the
double-differential production cross-section of charged pions in proton
interactions on nuclear targets at large angle. The HARP TPC operated with a
number of hardware shortfalls and operational mistakes. Thus it was important
to control and characterize its momentum calibration. While it was not possible
to enter a direct particle beam into the sensitive volume of the TPC to
calibrate the detector, a set of physical processes and detector properties
were exploited to achieve a precise calibration of the apparatus. In the
following we recall the main issues concerning the momentum measurement in the
HARP TPC, and describe the cross-checks made to validate the momentum scale. As
a conclusion, this analysis demonstrates that the measurement of momentum is
correct within the published precision of 3%.Comment: To be published by JINS
Measurement of the production cross-section of positive pions in the collision of 8.9 GeV/c protons on beryllium
The double-differential production cross-section of positive pions,
, measured in the HARP experiment is presented.
The incident particles are 8.9 GeV/c protons directed onto a beryllium target
with a nominal thickness of 5% of a nuclear interaction length. The measured
cross-section has a direct impact on the prediction of neutrino fluxes for the
MiniBooNE and SciBooNE experiments at Fermilab. After cuts, 13 million protons
on target produced about 96,000 reconstructed secondary tracks which were used
in this analysis. Cross-section results are presented in the kinematic range
0.75 GeV/c < < 6.5 GeV/c and 30 mrad < < 210 mrad in
the laboratory frame.Comment: 39 pages, 21 figures. Version accepted for publication by Eur. Phys.
J.
Posterior musculofascial reconstruction after radical prostatectomy: an updated systematic review and a meta-analysis
To evaluate the influence of posterior musculofascial plate reconstruction (PR) on early return of continence after radical prostatectomy (RP); an updated systematic review of the literature. A systematic review of the literature was performed in June 2015, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement and searching Medline, Embase, Scopus and Web of Science databases. We searched the terms posterior reconstruction prostatectomy, double layer anastomosis prostatectomy across the 'Title' and 'Abstract' fields of the records, with the following limits: humans, gender (male), and language (English). The authors reviewed the records to identify studies comparing cohorts of patients who underwent RP with or without restoration of the posterior aspect of the rhabdosphincter. A meta-analysis of the risk ratios estimated using data from the selected studies was performed. In all, 21 studies were identified, including three randomised controlled trials. The overall analysis of comparative studies showed that PR improved early continence recovery at 3-7, 30, and 90 days after catheter removal, while the continence rate at 180 days was statistically but not clinically affected. Statistically significantly lower anastomotic leakage rates were described after PR. There were no significant differences for positive surgical margins rates or for complications such as acute urinary retention and bladder neck stricture. The analysis confirms the benefits at 30 days after catheter removal already discussed in the review published in 2012, but also shows a significant advantage in terms of urinary continence recovery in the first 90 days. A multicentre prospective randomised controlled trial is currently being conducted in several institutions around the world to better assess the effectiveness of PR in facilitating an earlier recovery of postoperative urinary continence
NEXT-100 Technical Design Report (TDR). Executive Summary
In this Technical Design Report (TDR) we describe the NEXT-100 detector that
will search for neutrinoless double beta decay (bbonu) in Xe-136 at the
Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes
the design presented in our Conceptual Design Report (CDR): an
electroluminescence time projection chamber, with separate readout planes for
calorimetry and tracking, located, respectively, behind cathode and anode. The
detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or
100 kg at 10 bar. This option builds in the capability to increase the total
isotope mass by 50% while keeping the operating pressure at a manageable level.
The readout plane performing the energy measurement is composed of Hamamatsu
R11410-10 photomultipliers, specially designed for operation in low-background,
xenon-based detectors. Each individual PMT will be isolated from the gas by an
individual, pressure resistant enclosure and will be coupled to the sensitive
volume through a sapphire window. The tracking plane consists in an array of
Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged
in square boards holding 64 sensors (8 times8) with a 1-cm pitch. The inner
walls of the TPC, the sapphire windows and the boards holding the MPPCs will be
coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the
light collection.Comment: 32 pages, 22 figures, 5 table
- …