634 research outputs found

    Improved X-ray detection and particle identification with avalanche photodiodes

    Full text link
    Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to account for space dependent electron drift time. In addition, this waveform analysis is used for particle identification, e.g. to distinguish between x-rays and MeV electrons in our experiment.Comment: 6 pages, 6 figure

    Conventional and diffusion-weighted magnetic resonance imaging findings of benign fibromatous paratesticular tumor: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>The vast majority of paratesticular masses are benign. Magnetic resonance imaging of the scrotum may provide valuable information in the pre-operative work-up of scrotal masses, by allowing the precise localization of the lesion and helping in characterizing its nature. Diffusion-weighted magnetic resonance imaging is an evolving technique that can be used to improve tissue characterization, when interpreted with the findings of conventional magnetic resonance sequences. We present the case of an adenomatoid tumor of the tunica albuginea, with abundant fibrosis evaluated by magnetic resonance imaging of the scrotum, including both conventional and diffusion-weighted sequences. To the best of our knowledge, there are very few reports in the English literature regarding the magnetic resonance imaging features of this rare benign paratesticular tumor and no report on the diffusion-weighted magnetic resonance findings. We discuss the value of magnetic resonance imaging in the pre-operative diagnosis of benign fibromatous paratesticular tumors and differential diagnosis.</p> <p>Case presentation</p> <p>A 45-year-old Caucasian man was referred to us with a palpable left scrotal mass. Magnetic resonance imaging of his scrotum revealed the presence of a multilobular left paratesticular mass, mainly detected with very low signal intensity on T2-weighted images and restricted diffusion on apparent diffusion coefficient maps. These findings were suggestive of a fibrous component, and were confirmed on histology following lesion excision.</p> <p>Conclusion</p> <p>Magnetic resonance imaging of the scrotum, by using both conventional and diffusion-weighted sequences, could have a potential role in the evaluation of scrotal masses.</p

    Retroperitoneoscopic radical nephrectomy with a small incision for renal cell carcinoma: Comparison with the conventional method

    Get PDF
    <p>Abstract</p> <p>purpose</p> <p>When retroperitoneoscopic radical nephrectomy for renal cell carcinoma was introduced into our institution, we performed a combined small skin incision method. In this method, a small incision was made to approach the retroperitoneal space prior to setting trockers and thereafter a LAPDISC was placed in the incision to start the retroperitoneoscopic procedure. In this study, we compared the outcomes between the combined small skin incision method ("A method" hereinafter) and the conventional method ("B method" hereinafter).</p> <p>material and methods</p> <p>Among the cases of T1N0M0 suspicious renal cell carcinoma treated at Yokohama City University between May 2003 and June 2009, the A method was performed in 51 cases and the B method was performed in 33 cases. The factors in the outcomes compared between the A and B methods were the duration of procedure, volume of bleeding, volume of transfusion, weight of the specimen, incidence of peritoneal injury, rate of conversion to open surgery, and perioperative complications.</p> <p>results</p> <p>The duration of the procedure was 214.4 ± 46.9 minutes in the A method group and 208.1 ± 36.4 minutes in the B method group (p = 0.518). The volume of bleeding and the weight of the specimen were 105.5 ± 283.2 ml and 335.1 ± 137.4 g in the A method group and 44.8 ± 116 ml (p = 0.247) and 309.2 ± 126 g (p = 0.385) in the B method group. There was no significant difference in all factors analyzed.</p> <p>conclusion</p> <p>The A method would be highly possible to produce stable results, even during the introduction period when the staff and the institution are still unfamiliar with the retroperitoneoscopic surgery.</p

    Cytokine Profiles in Asthma Families Depend on Age and Phenotype

    Get PDF
    Background: Circulating cytokine patterns may be relevant for the diagnosis of asthma, for the discrimination of certain phenotypes, and prognostic factors for exacerbation of disease. Methodology/Principal Findings: In this study we investigated serum samples from 944 individuals of 218 asthma-affected families by a multiplex, microsphere based system detecting at high sensitivity eleven asthma associated mediators: eotaxin (CCL11), granulocyte macrophage stimulating factor (GM-CSF), interferon gamma (IFNγ), interleukin-4 (IL-4), IL-5, IL-8, IL-10, IL-12 (p40), IL-13, IL-17 and tumor necrosis factor alpha (TNFα). Single cytokine levels were largely similar between asthmatic and healthy individuals when analysing asthma as single disease entity. Regulatory differences between parental and pediatric asthma were reflected by six of the eleven mediators analyzed (eotaxin, IL-4, IL-5, IL-10, IL-12, TNFα). IL-12 (p40) and IL-5 were the best predictor for extrinsic asthma in children with an increased odds ratio of 2.85 and 1.96 per log pg/ml increase (IL-12 (p40): 1.2-6.8, p = 0.019, and IL-5: 1.2-2.5, p = 0.025). Frequent asthma attacks in children are associated with elevated IL-5 serum levels (p = 0.013). Cytokine patterns seem to be individually balanced in both, healthy and diseased adults and children, with various cytokines correlating among each other (IL-17 and IFNγ (rs = 0.67), IL-4 and IL-5 (rs = 0.55), IFNγ and GM-CSF (rs = 0.54)). Conclusion/Significance: Our data support mainly an age- but also an asthma phenotype-dependent systemic immune regulation. © 2010 Pukelsheim et al

    Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC

    Get PDF
    The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at centre-of-mass energies of sqrt(s) = 900 GeV and 7 TeV collected during 2009 and 2010. Then, using the decay of K_s and Lambda particles, the calorimeter response to specific types of particles (positively and negatively charged pions, protons, and anti-protons) is measured and compared to the Monte Carlo predictions. Finally, the jet energy scale uncertainty is determined by propagating the response uncertainty for single charged and neutral particles to jets. The response uncertainty is 2-5% for central isolated hadrons and 1-3% for the final calorimeter jet energy scale.Comment: 24 pages plus author list (36 pages total), 23 figures, 1 table, submitted to European Physical Journal
    corecore