37 research outputs found

    Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator.

    Get PDF
    Background The use of circular fixators for the treatment of tibial fractures is well established in the literature. The aim of this study was to compare the Ilizarov circular fixator (ICF) with the Taylor spatial frame (TSF) in terms of treatment results in consecutive patients with tibial fractures that required operative management. Method A retrospective analysis of patient records and radiographs was performed to obtain patient data, information on injury sustained, the operative technique used, time duration in frame, healing time and complications of treatment. The minimum follow-up was 24 months. Results Ten patients were treated with ICF between 2000 and 2005, while 15 patients have been treated with TSF since 2005. Two of the 10 treated with ICF and 5 of the 15 treated with TSF were open fractures. All patients went on to achieve complete union. Mean duration in the frame was 12.7 weeks for ICF and 14.8 weeks for the TSF group. Two patients in the TSF group had delayed union and required additional procedures including adjustment of fixator and bone grafting. There was one malunion in the TSF group that required osteotomy and reapplication of frame. There were seven and nine pin-site infections in the ICF and TSF groups, respectively, all of which responded to antibiotics. There were no refractures in either group. Conclusion In an appropriate patient, both types of circular fixator are equally effective but have different characteristics, with TSF allowing for postoperative deformity correction. Of concern are the two cases of delayed union in the TSF group, all in patients with high-energy injuries. We feel another larger study is required to provide further clarity in this matter. Level of evidence Level II—comparative study

    Methods for specifying the target difference in a randomised controlled trial : the Difference ELicitation in TriAls (DELTA) systematic review

    Get PDF
    Peer reviewedPublisher PD

    Quantitative radiologic criteria for the diagnosis of lumbar spinal stenosis: a systematic literature review

    Get PDF
    Background: Beside symptoms and clinical signs radiological findings are crucial in the diagnosis of lumbar spinal stenosis (LSS). We investigate which quantitative radiological signs are described in the literature and which radilogical criteria are used to establish inclusion criteria in clincical studies evaluating different treatments in patients with lumbar spinal stenosis. Methods: A literature search was performed in Medline, Embase and the Cochrane library to identify papers reporting on radiological criteria to describe LSS and systematic reviews investigating the effects of different treatment modalities. Results: 25 studies reporting on radiological signs of LSS and four systematic reviews related to the evaluation of different treatments were found. Ten different parameters were identified to quantify lumbar spinal stenosis. Most often reported measures for central stenosis were antero-posterior diameter (< 10 mm) and cross-sectional area (< 70 mm2) of spinal canal. For lateral stenosis height and depth of the lateral recess, and for foraminal stenosis the foraminal diameter were typically used. Only four of 63 primary studies included in the systematic reviews reported on quantitative measures for defining inclusion criteria of patients in prognostic studies. Conclusions: There is a need for consensus on well-defined, unambiguous radiological criteria to define lumbar spinal stenosis in order to improve diagnostic accuracy and to formulate reliable inclusion criteria for clinical studies

    A modified footplate for the Kerrison rongeur

    Get PDF
    Use of the Kerrison rongeur for bone removal in spinal surgery is associated with dural tears and cerebrospinal fluid (CSF) leaks. We report a modification of the Kerrison rongeur footplate designed to reduce the risk of dural tears. A novel footplate was designed by incorporating the following parameters: (1) tapering the footplate to deflect soft tissue downward during positioning of the rongeur underneath the bone, and (2) making the footplate longer and wider than the cutting element to prevent soft tissue from entering into the cutting surface. Stereolithography models of the modified footplate were made and tested in a cadaver. A stainless steel modified footplate was then incorporated into an existing Kerrison rongeur as a working prototype, and tested in 20 laminectomy cases to clinically validate its design. The modified footplate prevented soft tissue from entering the cutting surface of the Kerrison rongeur in the manner intended by its design. No dural tears or CSF leaks were encountered in any instance. Potential soft tissue compression caused by an increase in footplate dimensions was not a significant issue in the rongeur size tested. This modification, however, might not be practical in rongeurs larger than 3 mm. The risk of dural tears and cerebrospinal fluid leaks in spinal surgery may be reduced by this footplate modification of the Kerrison rongeur. Soft tissue compression may limit the incorporation of this modification to rongeurs of 3 mm or smaller. The promising results warrant further tests with a wider range of sizes.Center for Integration of Medicine and Innovative Technology (U.S. Army Medical Research Acquisition Activity Cooperative Agreement No. DAMD17-02-2-0006

    Variation in the provision and practice of implant-based breast reconstruction in the UK: Results from the iBRA national practice questionnaire

    Get PDF
    Introduction The introduction of biological and synthetic meshes has revolutionised the practice of implant-based breast reconstruction (IBBR) but evidence for effectiveness is lacking. The iBRA (implant Breast Reconstruction evAluation) study is a national trainee-led project that aims to explore the practice and outcomes of IBBR to inform the design of a future trial. We report the results of the iBRA National Practice Questionnaire (NPQ) which aimed to comprehensively describe the provision and practice of IBBR across the UK. Methods A questionnaire investigating local practice and service provision of IBBR developed by the iBRA Steering Group was completed by trainee and consultant leads at breast and plastic surgical units across the UK. Summary data for each survey item were calculated and variation between centres and overall provision of care examined. Results 81 units within 79 NHS-hospitals completed the questionnaire. Units offered a range of reconstructive techniques, with IBBR accounting for 70% (IQR:50–80%) of participating units' immediate procedures. Units on average were staffed by 2.5 breast surgeons (IQR:2.0–3.0) and 2.0 plastic surgeons (IQR:1.0–3.0) performing 35 IBBR cases per year (IQR:20-50). Variation was demonstrated in the provision of novel different techniques for IBBR especially the use of biological (n = 62) and synthetic (n = 25) meshes and in patient selection for these procedures. Conclusions The iBRA-NPQ has demonstrated marked variation in the provision and practice of IBBR in the UK. The prospective audit phase of the iBRA study will determine the safety and effectiveness of different approaches to IBBR and allow evidence-based best practice to be explored

    National Clinical Guidelines for non-surgical treatment of patients with recent onset low back pain or lumbar radiculopathy

    Get PDF

    Laparoscopy in management of appendicitis in high-, middle-, and low-income countries: a multicenter, prospective, cohort study.

    Get PDF
    BACKGROUND: Appendicitis is the most common abdominal surgical emergency worldwide. Differences between high- and low-income settings in the availability of laparoscopic appendectomy, alternative management choices, and outcomes are poorly described. The aim was to identify variation in surgical management and outcomes of appendicitis within low-, middle-, and high-Human Development Index (HDI) countries worldwide. METHODS: This is a multicenter, international prospective cohort study. Consecutive sampling of patients undergoing emergency appendectomy over 6 months was conducted. Follow-up lasted 30 days. RESULTS: 4546 patients from 52 countries underwent appendectomy (2499 high-, 1540 middle-, and 507 low-HDI groups). Surgical site infection (SSI) rates were higher in low-HDI (OR 2.57, 95% CI 1.33-4.99, p = 0.005) but not middle-HDI countries (OR 1.38, 95% CI 0.76-2.52, p = 0.291), compared with high-HDI countries after adjustment. A laparoscopic approach was common in high-HDI countries (1693/2499, 67.7%), but infrequent in low-HDI (41/507, 8.1%) and middle-HDI (132/1540, 8.6%) groups. After accounting for case-mix, laparoscopy was still associated with fewer overall complications (OR 0.55, 95% CI 0.42-0.71, p < 0.001) and SSIs (OR 0.22, 95% CI 0.14-0.33, p < 0.001). In propensity-score matched groups within low-/middle-HDI countries, laparoscopy was still associated with fewer overall complications (OR 0.23 95% CI 0.11-0.44) and SSI (OR 0.21 95% CI 0.09-0.45). CONCLUSION: A laparoscopic approach is associated with better outcomes and availability appears to differ by country HDI. Despite the profound clinical, operational, and financial barriers to its widespread introduction, laparoscopy could significantly improve outcomes for patients in low-resource environments. TRIAL REGISTRATION: NCT02179112

    Pooled analysis of WHO Surgical Safety Checklist use and mortality after emergency laparotomy

    Get PDF
    Background The World Health Organization (WHO) Surgical Safety Checklist has fostered safe practice for 10 years, yet its place in emergency surgery has not been assessed on a global scale. The aim of this study was to evaluate reported checklist use in emergency settings and examine the relationship with perioperative mortality in patients who had emergency laparotomy. Methods In two multinational cohort studies, adults undergoing emergency laparotomy were compared with those having elective gastrointestinal surgery. Relationships between reported checklist use and mortality were determined using multivariable logistic regression and bootstrapped simulation. Results Of 12 296 patients included from 76 countries, 4843 underwent emergency laparotomy. After adjusting for patient and disease factors, checklist use before emergency laparotomy was more common in countries with a high Human Development Index (HDI) (2455 of 2741, 89.6 per cent) compared with that in countries with a middle (753 of 1242, 60.6 per cent; odds ratio (OR) 0.17, 95 per cent c.i. 0.14 to 0.21, P <0001) or low (363 of 860, 422 per cent; OR 008, 007 to 010, P <0.001) HDI. Checklist use was less common in elective surgery than for emergency laparotomy in high-HDI countries (risk difference -94 (95 per cent c.i. -11.9 to -6.9) per cent; P <0001), but the relationship was reversed in low-HDI countries (+121 (+7.0 to +173) per cent; P <0001). In multivariable models, checklist use was associated with a lower 30-day perioperative mortality (OR 0.60, 0.50 to 073; P <0.001). The greatest absolute benefit was seen for emergency surgery in low- and middle-HDI countries. Conclusion Checklist use in emergency laparotomy was associated with a significantly lower perioperative mortality rate. Checklist use in low-HDI countries was half that in high-HDI countries.Peer reviewe

    Feasibility work to inform the design of a randomized clinical trial of wound dressings in elective and unplanned abdominal surgery

    Get PDF
    Background: Designing RCTs in surgery requires consideration of existing evidence, stakeholders' views and emerging interventions, to ensure that research questions are relevant to patients, surgeons and the health service. When there is uncertainty about RCT design, feasibility work is recommended. This study aimed to assess how feasibility work could inform the design of a future pilot study and RCT (Bluebelle, HTA ‐ 12/200/04). Methods: This was a prospective survey of dressings used to cover abdominal wounds. Surgical trainees from 25 hospitals were invited to participate. Information on patient risk factors, operation type and type of wound dressings used was recorded for elective and unplanned abdominal procedures over a 2‐week interval. The types of dressing used were summarized, and associations with operation type and patient risk factors explored. Results: Twenty hospitals participated, providing data from 727 patients (1794 wounds). Wounds were predominantly covered with basic dressings (1203 of 1769, 68·0 per cent) and tissue adhesive was used in 27·4 per cent (485 of 1769); dressing type was missing for 25 wounds. Just 3·6 per cent of wounds (63 of 1769) did not have a dressing applied at the end of the procedure. There was no evidence of an association between type of dressing used and patient risk factors, type of operation, or elective and unscheduled surgery. Conclusion: Based on the findings from this large study of current practice, the pilot study design has evolved. The inclusion criteria have expanded to encompass patients undergoing unscheduled surgery, and tissue adhesive as a dressing will be evaluated as an additional intervention group. Collaborative methods are recommended to inform the design of RCTs in surgery, helping to ensure they are relevant to current practice
    corecore