299 research outputs found

    Potential advantages in heat and power production when biogas is collected from several digesters using dedicated pipelines - A case study in the "Province of West-Flanders" (Belgium)

    Get PDF
    In the case study “West-Flanders” costs of electricity and heat production are estimated if a dedicated biogas grid using pipelines would be implemented to centralize energy production in a region. Heat may not be used effectively at digester sites, e.g. because of a change in treatment of digestate. A large scale centralized combined heat and power (CHP) engine can produce additional electrical power at a hub, i.e. central collection point, and has lower specific costs compared to decentralized CHPs at digester sites. A biogas transport model is used to calculate transport costs in a grid. These costs, partly balanced by a scale advantage in CHP costs, are attributed to the additional electrical energy (80%) and heat (20%) produced. If the hub is at a digester site, costs of additional electricity can be as low as 4.0 €ct kWhe−1 and are in many cases below 12 €ct kWhe−1, i.e. in the same order of magnitude or lower than costs of electricity from biogas produced using separate CHPs at the different digester sites; costs of heat at the hub show to be lower than 1 €ct kWhth−1 assuming an effective heat use of 50%. In case a hub is situated at a location with high potential heat demand, i.e. a heat sink, transport of biogas from one digester only to a central located hub can provide 3.4 MWth of heat at 1.95 €ct kWhth−1. For such a centrally located hub additional electrical energy costs show to be slightly higher, but with three or more digesters these costs are lower than 20 €ct kWhe−1 and heat costs are around 0.5 €ct kWhth−1. With a centralized hub more renewable energy is produced, i.e. a more efficient use of biomass feedstock. It is concluded that costs for additional electricity and heat can be at a competing level and scale advantages in a CHP can be a driver to collect biogas at a hub using a biogas grid

    Impact of infection on proteome-wide glycosylation revealed by distinct signatures for bacterial and viral pathogens

    Get PDF
    Mechanisms of infection and pathogenesis have predominantly been studied based on differential gene or protein expression. Less is known about posttranslational modifications, which are essential for protein functional diversity. We applied an innovative glycoproteomics method to study the systemic proteome-wide glycosylation in response to infection. The protein site-specific glycosylation was characterized in plasma derived from well-defined controls and patients. We found 3862 unique features, of which we identified 463 distinct intact glycopeptides, that could be mapped to more than 30 different proteins. Statistical analyses were used to derive a glycopeptide signature that enabled significant differentiation between patients with a bacterial or viral infection. Furthermore, supported by a machine learning algorithm, we demonstrated the ability to identify the causative pathogens based on the distinctive host blood plasma glycopeptide signatures. These results illustrate that glycoproteomics holds enormous potential as an innovative approach to improve the interpretation of relevant biological changes in response to infection

    Neurocognitive functioning in school-aged cystinosis patients

    Get PDF
    Contains fulltext : 89600.pdf (publisher's version ) (Closed access)INTRODUCTION: Cystinosis is an autosomal recessive disorder leading to intralysosomal cystine accumulation in various tissues. It causes renal Fanconi syndrome and end stage renal failure around the age of 10 years if not treated with cysteamine. Children with cystinosis seem to have a normal intelligence but frequently show learning difficulties. These problems may be due to specific neurocognitive deficits rather than impaired renal function. Whether cysteamine treatment can improve cognitive functioning of cystinosis patients is thus far unknown. We aim to analyze neurocognitive functioning of school-aged cystinosis patients treated with cysteamine in order to identify specific deficits that can lead to learning difficulties. PATIENTS AND METHODS: Fourteen Dutch and Belgian school-aged cystinosis patients were included. Glomerular filtration rate was estimated using the Schwartz formula. Children were tested for general intelligence, visual-motor integration, inhibition, interference, sustained attention, accuracy, planning, visual memory, processing speed, motor planning, fluency and speed, and behavioural and emotional functioning using standardized methods. RESULTS: Glomerular filtration rate ranged from 22 to 120 ml min(-1) 1.73 m(-2). Median full-scale intelligence was below the average of a normal population (87, range 60-132), with a discrepancy between verbal (median 95, range 60-125) and performance (median 87, range 65-130) intelligence. Over 50% of the patients scored poorly on visual-motor integration, sustained attention, visual memory, planning, or motor speed. The other tested areas showed no differences between patients' and normal values. CONCLUSION: Neurocognitive diagnostics are indicated in cystinosis patients. Early recognition of specific deficits and supervision from special education services might reduce learning difficulties and improve school careers.1 december 201

    HBM4EU chromates study - Overall results and recommendations for the biomonitoring of occupational exposure to hexavalent chromium

    Get PDF
    Exposure to hexavalent chromium [Cr(VI)] may occur in several occupational activities, e.g., welding, Cr(VI) electroplating and other surface treatment processes. The aim of this study was to provide EU relevant data on occupational Cr(VI) exposure to support the regulatory risk assessment and decision-making. In addition, the capability and validity of different biomarkers for the assessment of Cr(VI) exposure were evaluated. The study involved nine European countries and involved 399 workers in different industry sectors with exposures to Cr(VI) such as welding, bath plating, applying or removing paint and other tasks. We also studied 203 controls to establish a background in workers with no direct exposure to Cr(VI). We applied a cross-sectional study design and used chromium in urine as the primary biomonitoring method for Cr(VI) exposure. Additionally, we studied the use of red blood cells (RBC) and exhaled breath condensate (EBC) for biomonitoring of exposure to Cr(VI). Personal measurements were used to study exposure to inhalable and respirable Cr(VI) by personal air sampling. Dermal exposure was studied by taking hand wipe samples. The highest internal exposures were observed in the use of Cr(VI) in electrolytic bath plating. In stainless steel welding the internal Cr exposure was clearly lower when compared to plating activities. We observed a high correlation between chromium urinary levels and air Cr(VI) or dermal total Cr exposure. Urinary chromium showed its value as a first approach for the assessment of total, internal exposure. Correlations between urinary chromium and Cr(VI) in EBC and Cr in RBC were low, probably due to differences in kinetics and indicating that these biomonitoring approaches may not be interchangeable but rather complementary. This study showed that occupational biomonitoring studies can be conducted successfully by multi-national collaboration and provide relevant information to support policy actions aiming to reduce occupational exposure to chemicals.This work has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement No 733032 and received co-funding from the author's organizations and/or Ministries. Luxembourg entered the study at a later stage and thus financed the study at its own means.S

    The COMPASS Experiment at CERN

    Get PDF
    The COMPASS experiment makes use of the CERN SPS high-intensitymuon and hadron beams for the investigation of the nucleon spin structure and the spectroscopy of hadrons. One or more outgoing particles are detected in coincidence with the incoming muon or hadron. A large polarized target inside a superconducting solenoid is used for the measurements with the muon beam. Outgoing particles are detected by a two-stage, large angle and large momentum range spectrometer. The setup is built using several types of tracking detectors, according to the expected incident rate, required space resolution and the solid angle to be covered. Particle identification is achieved using a RICH counter and both hadron and electromagnetic calorimeters. The setup has been successfully operated from 2002 onwards using a muon beam. Data with a hadron beam were also collected in 2004. This article describes the main features and performances of the spectrometer in 2004; a short summary of the 2006 upgrade is also given.Comment: 84 papes, 74 figure

    Future axion searches with the International Axion Observatory (IAXO)

    Get PDF
    The International Axion Observatory (IAXO) is a new generation axion helioscope aiming at a sensitivity to the axion-photon coupling of ga\u3b3 3c few 7 10-12 GeV-1, i.e. 1-1.5 orders of magnitude beyond the one achieved by CAST, currently the most sensitive axion helioscope. The main elements of IAXO are an increased magnetic field volume together with extensive use of x-ray focusing optics and low background detectors, innovations already successfully tested in CAST. Additional physics cases of IAXO could include the detection of electron-coupled axions invoked to explain the white dwarf cooling, relic axions, and a large variety of more generic axion-like particles (ALPs) and other novel excitations at the low-energy frontier of elementary particle physics

    Patient safety in remote primary care encounters: multimethod qualitative study combining Safety I and Safety II analysis

    Get PDF
    Abstract Background Triage and clinical consultations increasingly occur remotely. We aimed to learn why safety incidents occur in remote encounters and how to prevent them. Setting and sample UK primary care. 95 safety incidents (complaints, settled indemnity claims and reports) involving remote interactions. Separately, 12 general practices followed 2021–2023. Methods Multimethod qualitative study. We explored causes of real safety incidents retrospectively (‘Safety I’ analysis). In a prospective longitudinal study, we used interviews and ethnographic observation to produce individual, organisational and system-level explanations for why safety and near-miss incidents (rarely) occurred and why they did not occur more often (‘Safety II’ analysis). Data were analysed thematically. An interpretive synthesis of why safety incidents occur, and why they do not occur more often, was refined following member checking with safety experts and lived experience experts. Results Safety incidents were characterised by inappropriate modality, poor rapport building, inadequate information gathering, limited clinical assessment, inappropriate pathway (eg, wrong algorithm) and inadequate attention to social circumstances. These resulted in missed, inaccurate or delayed diagnoses, underestimation of severity or urgency, delayed referral, incorrect or delayed treatment, poor safety netting and inadequate follow-up. Patients with complex pre-existing conditions, cardiac or abdominal emergencies, vague or generalised symptoms, safeguarding issues, failure to respond to previous treatment or difficulty communicating seemed especially vulnerable. General practices were facing resource constraints, understaffing and high demand. Triage and care pathways were complex, hard to navigate and involved multiple staff. In this context, patient safety often depended on individual staff taking initiative, speaking up or personalising solutions. Conclusion While safety incidents are extremely rare in remote primary care, deaths and serious harms have resulted. We offer suggestions for patient, staff and system-level mitigations

    The IAXO Helioscope

    Get PDF
    The IAXO (International Axion Experiment) is a fourth generation helioscope with a sensitivity, in terms of detectable signal counts, at least 104 better than CAST phase-I, resulting in sensitivity on gaÂż one order of magnitude better. To achieve this performance IAXO will count on a 8-coil toroidal magnet with 60 cm diameter bores and equipped with X-ray focusing optics into 0.20 cm2 spots coupled to ultra-low background Micromegas X-ray detectors. The magnet will be on a platform that will allow solar tracking for 12 hours per day. The next short term objectives are to prepare a Technical Design Report and to construct the first prototypes of the hardware main ingredients: demonstration coil, X-ray optics and low background detector while refining the physics case and studying the feasibility studies for Dark Matter axions

    The Next Generation of Axion Helioscopes: The International Axion Observatory (IAXO)

    Get PDF
    The International Axion Observatory (IAXO) is a proposed 4th-generation axion helioscope with the primary physics research goal to search for solar axions via their Primakoff conversion into photons of 1 \u2013 10 keV energies in a strong magnetic field. IAXO will achieve a sensitivity to the axion-photon coupling ga\u3b3 down to a few 710 1212 GeV 121 for a wide range of axion masses up to 3c 0.25 eV. This is an improvement over the currently best (3rd generation) axion helioscope, the CERN Axion Solar Telescope (CAST), of about 5 orders of magnitude in signal strength, corresponding to a factor 3c 20 in the axion photon coupling. IAXO's sensitivity relies on the construction of a large superconducting 8-coil toroidal magnet of 20 m length optimized for axion research. Each of the eight 60 cm diameter magnet bores is equipped with x-ray optics focusing the signal photons into 3c 0.2 cm2 spots that are imaged by very low background x-ray detectors. The magnet will be built into a structure with elevation and azimuth drives that will allow solar tracking for 12 hours each day. This contribution is a summary of our papers [1], [2] and [3] and we refer to these for further details
    • 

    corecore