227 research outputs found
Transverse NMR relaxation in magnetically heterogeneous media
We consider the NMR signal from a permeable medium with a heterogeneous
Larmor frequency component that varies on a scale comparable to the
spin-carrier diffusion length. We focus on the mesoscopic part of the
transverse relaxation, that occurs due to dispersion of precession phases of
spins accumulated during diffusive motion. By relating the spectral lineshape
to correlation functions of the spatially varying Larmor frequency, we
demonstrate how the correlation length and the variance of the Larmor frequency
distribution can be determined from the NMR spectrum. We corroborate our
results by numerical simulations, and apply them to quantify human blood
spectra.Comment: 9 pages, 4 figure
3D diffusion-weighted (129) Xe MRI for whole lung morphometry
PURPOSE: To obtain whole lung morphometry measurements from (129) Xe in a single breath-hold with 3D multiple b-value (129) Xe diffusion-weighted MRI (DW-MRI) with an empirically optimized diffusion time and compressed sensing for scan acceleration. METHODS: Prospective three-fold undersampled 3D multiple b-value hyperpolarized (129) Xe DW-MRI datasets were acquired, and the diffusion time (Δ) was iterated so as to provide diffusive length scale (LmD ) estimates from the stretched exponential model (SEM) that are comparable to those from (3) He. The empirically optimized (129) Xe diffusion time was then implemented with a four-fold undersampling scheme and was prospectively benchmarked against (3) He measurements in a cohort of five healthy volunteers, six ex-smokers, and two chronic obstructive pulmonary disease patients using both SEM-derived LmD and cylinder model (CM)-derived mean chord length (Lm). RESULTS: Good agreement between the mean (129) Xe and (3) He LmD (mean difference, 2.2%) and Lm (mean difference, 1.1%) values was obtained in all subjects at an empirically optimized (129) Xe Δ = 8.5 ms. CONCLUSION: Compressed sensing has facilitated single-breath 3D multiple b-value (129) Xe DW-MRI acquisitions, and results at (129) Xe Δ = 8.5 ms indicate that (129) Xe provides a viable alternative to (3) He for whole lung morphometry mapping with either the SEM or CM. Magn Reson Med, 2017. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited
Comparison of in vivo lung morphometry models from 3D multiple b-value 3He and 129Xe diffusion-weighted MRI
Purpose
To compare in vivo lung morphometry parameters derived from theoretical gas diffusion models, the cylinder model and stretched exponential model, in a range of acinar microstructural length scales encountered in healthy and diseased lungs with 3He and 129Xe diffusion‐weighted MRI.
Methods
Three‐dimensional multiple b‐value 3He and 129Xe diffusion‐weighted MRI was acquired with compressed sensing at 1.5 T from 51 and 31 subjects, respectively, including healthy volunteers, ex‐smokers, idiopathic pulmonary fibrosis, and chronic obstructive pulmonary disease patients. For each subject, the stretched exponential model–derived mean diffusive length scale (LmD) was calculated from the diffusion signal decay, and was compared with the cylinder model–derived mean chord length (Lm) and mean alveolar diameter (LAlv) in order to determine the relationships among the different lung morphometry parameters.
Results
For both 3He and 129Xe diffusion‐weighted MRI, the mean global LmD value was significantly related (P < .001) to Lm in a nonlinear power relationship, whereas the LAlv demonstrated excellent linear correlation (P < .001) with LmD. A mean bias of +1.0% and urn:x-wiley:07403194:media:mrm27608:mrm27608-math-00012.6% toward LmD was obtained for Bland‐Altman analyses of 3He and 129Xe LmD and LAlv values, suggesting that the two morphometric parameters are equivalent measures of mean acinar dimensions.
Conclusion
Within the experimental range of parameters considered here for both 3He and 129Xe, the stretched exponential model–derived LmD is related nonlinearly to cylinder model–derived Lm, and demonstrates excellent agreement with the cylinder model–derived LAlv
Evaluating brain damage in multiple sclerosis with simultaneous multi-angular-relaxometry of tissue
OBJECTIVE: Multiple sclerosis (MS) is a common demyelinating central nervous system disease. MRI methods that can quantify myelin loss are needed for trials of putative remyelinating agents. Quantitative magnetization transfer MRI introduced the macromolecule proton fraction (MPF), which correlates with myelin concentration. We developed an alternative approach, Simultaneous-Multi-Angular-Relaxometry-of-Tissue (SMART) MRI, to generate MPF. Our objective was to test SMART-derived MPF metric as a potential imaging biomarker of demyelination.
METHODS: Twenty healthy control (HC), 11 relapsing-remitting MS (RRMS), 22 progressive MS (PMS), and one subject with a biopsied tumefactive demyelinating lesion were scanned at 3T using SMART MRI. SMART-derived MPF metric was determined in normal-appearing cortical gray matter (NAGM), normal-appearing subcortical white matter (NAWM), and demyelinating lesions. MPF metric was evaluated for correlations with physical and cognitive test scores. Comparisons were made between HC and MS and between MS subtypes. Furthermore, correlations were determined between MPF and neuropathology in the biopsied person.
RESULTS: SMART-derived MPF in NAGM and NAWM were lower in MS than HC (p \u3c 0.001). MPF in NAGM, NAWM and lesions differentiated RRMS from PMS (p \u3c 0.01, p \u3c 0.001, p \u3c 0.001, respectively), whereas lesion volumes did not. MPF in NAGM, NAWM and lesions correlated with the Expanded Disability Status Scale (p \u3c 0.01, p \u3c 0.001, p \u3c 0.001, respectively) and nine-hole peg test (p \u3c 0.001, p \u3c 0.001, p \u3c 0.01, respectively). MPF was lower in the histopathologically confirmed inflammatory demyelinating lesion than the contralateral NAWM and increased in the biopsied lesion over time, mirroring improved clinical performance.
INTERPRETATION: SMART-derived MPF metric holds potential as a quantitative imaging biomarker of demyelination and remyelination
Anomalies of ac driven solitary waves with internal modes: Nonparametric resonances induced by parametric forces
We study the dynamics of kinks in the model subjected to a
parametric ac force, both with and without damping, as a paradigm of solitary
waves with internal modes. By using a collective coordinate approach, we find
that the parametric force has a non-parametric effect on the kink motion.
Specifically, we find that the internal mode leads to a resonance for
frequencies of the parametric driving close to its own frequency, in which case
the energy of the system grows as well as the width of the kink. These
predictions of the collective coordinate theory are verified by numerical
simulations of the full partial differential equation. We finally compare this
kind of resonance with that obtained for non-parametric ac forces and conclude
that the effect of ac drivings on solitary waves with internal modes is exactly
the opposite of their character in the partial differential equation.Comment: To appear in Phys Rev
Neck-cooling improves repeated sprint performance in the heat
The present study evaluated the effect of neck-cooling during exercise on repeated sprint ability in a hot environment. Seven team-sport playing males completed two experimental trials involving repeated sprint exercise (5 × 6 s) before and after two 45 min bouts of a football specific intermittent treadmill protocol in the heat (33.0 ± 0.2°C; 53 ± 2% relative humidity). Participants wore a neck-cooling collar in one of the trials (CC). Mean power output and peak power output declined over time in both trials but were higher in CC (540 ± 99 v 507 ± 122 W, d = 0.32; 719 ± 158 v 680 ± 182 W, d = 0.24 respectively). The improved power output was particularly pronounced (d = 0.51–0.88) after the 2nd 45 min bout but the CC had no effect on % fatigue. The collar lowered neck temperature and the thermal sensation of the neck (P 0.05). There were no trial differences but interaction effects were demonstrated for prolactin concentration and rating of perceived exertion (RPE). Prolactin concentration was initially higher in the collar cold trial and then was lower from 45 min onwards (interaction trial × time P = 0.04). RPE was lower during the football intermittent treadmill protocol in the collar cold trial (interaction trial × time P = 0.01). Neck-cooling during exercise improves repeated sprint performance in a hot environment without altering physiological or neuroendocrinological responses. RPE is reduced and may partially explain the performance improvement
Soliton ratchets induced by ac forces with harmonic mixing
The ratchet dynamics of a kink (topological soliton) of a dissipative
sine-Gordon equation in the presence of ac forces with harmonic mixing (at
least bi-harmonic) of zero mean is studied. The dependence of the kink mean
velocity on system parameters is investigated numerically and the results are
compared with a perturbation analysis based on a point particle representation
of the soliton. We find that first order perturbative calculations lead to
incomplete descriptions, due to the important role played by the soliton-phonon
interaction in establishing the phenomenon. The role played by the temporal
symmetry of the system in establishing soliton ratchets is also emphasized. In
particular, we show the existence of an asymmetric internal mode on the kink
profile which couples to the kink translational mode through the damping in the
system. Effective soliton transport is achieved when the internal mode and the
external force get phase locked. We find that for kinks driven by bi-harmonic
drivers consisting of the superposition of a fundamental driver with its first
odd harmonic, the transport arises only due to this {\it internal mode}
mechanism, while for bi-harmonic drivers with even harmonic superposition, also
a point-particle contribution to the drift velocity is present. The phenomenon
is robust enough to survive the presence of thermal noise in the system and can
lead to several interesting physical applications.Comment: 9 pages, 13 figure
Broken symmetries and directed collective energy transport
We study the appearance of directed energy current in homogeneous spatially
extended systems coupled to a heat bath in the presence of an external ac field
E(t). The systems are described by nonlinear field equations. By making use of
a symmetry analysis we predict the right choice of E(t) and obtain directed
energy transport for systems with a nonzero topological charge Q. We
demonstrate that the symmetry properties of motion of topological solitons
(kinks and antikinks) are equivalent to the ones for the energy current.
Numerical simulations confirm the predictions of the symmetry analysis and,
moreover, show that the directed energy current drastically increases as the
dissipation parameter reduces. Our results generalize recent rigorous
theories of currents generated by broken time-space symmetries to the case of
interacting many-particle systems.Comment: 4 pages, 2 figure
Random walk with barriers: Diffusion restricted by permeable membranes
Restrictions to molecular motion by barriers (membranes) are ubiquitous in
biological tissues, porous media and composite materials. A major challenge is
to characterize the microstructure of a material or an organism
nondestructively using a bulk transport measurement. Here we demonstrate how
the long-range structural correlations introduced by permeable membranes give
rise to distinct features of transport. We consider Brownian motion restricted
by randomly placed and oriented permeable membranes and focus on the
disorder-averaged diffusion propagator using a scattering approach. The
renormalization group solution reveals a scaling behavior of the diffusion
coefficient for large times, with a characteristically slow inverse square root
time dependence. The predicted time dependence of the diffusion coefficient
agrees well with Monte Carlo simulations in two dimensions. Our results can be
used to identify permeable membranes as restrictions to transport in disordered
materials and in biological tissues, and to quantify their permeability and
surface area.Comment: 8 pages, 3 figures; origin of dispersion clarified, refs adde
Regional pressure and temperature differences across the injured human brain : comparisons between intraparenchymal and ventricular measurements
Introduction: Intraparenchymal, multimodality sensors are commonly used in the management of patients with severe traumatic brain injury (TBI). The ‘gold standard’, based on accuracy, reliability and cost for intracranial pressure (ICP) monitoring is within the cerebral ventricle (external strain gauge). There are no standards yet for intracerebral temperature monitoring and little is known of temperature differences between brain tissue and ventricle. The aim of the study therefore was to determine pressure and temperature differences at intraparenchymal and ventricular sites during five days of continuous neurominitoring.
Methods: Patients with severe TBI requiring emergency surgery. Inclusion criteria: patients who required ICP monitoring were eligible for recruitment. Two intracerebral probe types were used: a) intraventricular, dual parameter sensor (measuring pressure, temperature) with inbuilt catheter for CSF drainage: b) multiparameter intraparenchymal sensor measuring pressure, temperature and oxygen partial pressure. All sensors were inserted during surgery and under aseptic conditions.
Results: Seventeen patients, 12 undergoing neurosurgery (decompressive craniectomy n=8, craniotomy n=4) aged 21–78 years were studied. Agreement of measures for 9540 brain tissue-ventricular temperature ‘pairs’ and 10,291 brain tissue-ventricular pressure ‘pairs’ were determined using mixed model to compare mean temperature and pressure for longitudinal data. There was no significant overall difference for mean temperature (p=0.92) or mean pressure readings (p=0.379) between tissue and ventricular sites. With 95.8% of paired temperature readings within 2SD (−0.4 to 0.4°C) differences in temperature between brain tissue and ventricle were clinically insignificant. For pressure, 93.5% of readings pairs fell within the 2SD range (−9.4756 to 7.8112 mmHg) (Fig. 2). However, for individual patients, agreement for mean tissue-ventricular pressure differences was poor on occasions.
Conclusions: There is good overall agreement between paired temperature measurements obtained from deep white matter and brain ventricle in patients with and without early neurosurgery. For paired ICP measurements, 93.5% of readings were within 2SD of mean difference. Whilst the majority of paired readings were comparable (within 10mmHg) clinically relevant tissue-ventricular dissociations were noted. Further work is required to unravel the events responsible for short intervals of pressure dissociation before tissue pressure readings can be definitively accepted as a reliable surrogate for ventricular pressure.</p
- …