138 research outputs found
Recommended from our members
Hydrogen peroxide production of underwater nanosecond-pulsed streamer discharges with respect to pulse parameters and associated discharge characteristics
Abstract Pulsed streamer discharges submerged in water have demonstrated potential in a number of applications. Especially the generation of discharges by short high-voltage pulses in the nanosecond range has been found to offer advantages with respect to efficacies and efficiencies. The exploited plasma chemistry generally relies on the initial production of short-lived species, e.g. hydroxyl radicals. Since the diagnostic of these transient species is not readily possible, a quantification of hydrogen peroxide provides an adequate assessment of underlying reactions. These conceivably depend on the characteristics of the high-voltage pulses, such as pulse duration, pulse amplitude, as well as pulse steepness. A novel electrochemical flow-injection system was used to relate these parameters to hydrogen peroxide concentrations. Accordingly, the accumulated hydrogen peroxide production for streamer discharges ignited in deionized water was investigated for pulse durations of 100 ns and 300 ns, pulse amplitudes between 54 kV and 64 kV, and pulse rise times from 16 ns to 31 ns. An independent control of the individual pulse parameters was enabled by providing the high-voltage pulses with a Blumlein line. Applied voltage, discharge current, optical light emission and time-integrated images were recorded for each individual discharge to determine dissipated energy, inception statistic, discharge expansion and the lifetime of a discharge. Pulse steepness did not affect the hydrogen peroxide production rate, but an increase in amplitude of 10 kV for 100 ns pulses nearly doubled the rate to (0.19 ± 0.01) mol lâ1 sâ1, which was overall the highest determined rate. The energy efficiency did not change with pulse amplitude, but was sensitive to pulse duration. Notably, production rate and efficiency doubled when the pulse duration decreased from 300 ns to 100 ns, resulting in the best peroxide production efficiency of (9.2 ± 0.9) g kWhâ1. The detailed analysis revealed that the hydrogen peroxide production rate could be described by the energy dissipation in a representative single streamer. The production efficiency was affected by the corresponding discharge volume, which was comprised by the collective volume of all filaments. Hence, dissipating more energy in a filament resulted in an increased production rate, while increasing the relative volume of the discharge compared to its propagation time increased the energy efficiency
Alterations in regulatory T cells and immune checkpoint molecules in pancreatic cancer patients receiving FOLFIRINOX or gemcitabine plus nab-paclitaxel
PURPOSE This pilot study aimed on generating insight on alterations in circulating immune cells during the use of FOLFIRINOX and gemcitabine/nab-paclitaxel in pancreatic ductal adenocarcinoma (PDAC). PATIENTS AND METHODS Peripheral blood mononuclear cells were isolated before and 30~days after initiation of chemotherapy from 20 patients with advanced PDAC. Regulatory T cells (FoxP3+) and immune checkpoints (PD-1 and TIM-3) were analyzed by flow cytometry and immunological changes were correlated with clinical outcome. RESULTS Heterogeneous changes during chemotherapy were observed in circulating T-cell subpopulations with a pronounced effect on PD-1+ CD4+/CD8+ T cells. An increase in FoxP3+ or PD-1+ T cells had no significant effect on survival. An increase in TIM3+/CD8+ (but not TIM3+/CD4+) T cells was associated with a significant inferior outcome: median progression-free survival in the subgroup with an increase of TIM-3+/CD8+ T cells was 6.0 compared to 14.0~months in patients with a decrease/no change (p = 0.026); corresponding median overall survival was 13.0 and 20.0~months (p = 0.011), respectively. CONCLUSIONS Chemotherapy with FOLFIRNOX or gemcitabine/nab-paclitaxel induces variable changes in circulating T-cell populations that may provide prognostic information in PDAC
Design and acoustic tests of the ATHENA WFI filter wheel assembly development model towards TRL5
The filter wheel (FW) assembly (FWA), developed by the CBK Institute, is one of the critical subsystems of the wide field imager (WFI) instrument on board the Advanced Telescope for High Energy Astrophysicsâmission of the ESA Cosmic Vision 2015-25 space science program (launch scheduled around 2035). The instrument has to collect soft x-rays with very high quantum efficiency, thus WFI requires extremely thin optical blocking filter (OBF). Due to its thickness (âŒ150 nm) and large area (âŒ170 mm Ă 170 mm) needed to achieve a 40 âČ Ă 40 âČ instrument field of view, the filter is extremely vulnerable to acoustic loads generated during Ariane 6 rocket launch. On the other side, FW mechanism has to provide high overall reliability, so it is more favourable to launch the instrument in atmospheric pressure (without vacuum enclosure for filter protection). Design efforts of the FW subsystem were focused on two issues: providing maximal possible sound pressure level suppression and smallest possible differential pressure across the OBF, which should prevent filters from damaging. We describe the design of a reconfigurable acoustic-demonstrator model (DM) of WFI FWA created for purposes of acoustic testing. Also, the acoustic test campaign is described: test methodology, test criteria, and results discussion and its implication on future FWA design. In general, tests conducted with the FWA DM showed that current design of WFI is feasible and the project can be continued without introducing a vacuum enclosure, which would significantly increase system complexity and mass
Cylindrospermopsin is effectively degraded in water by pulsed corona-like and dielectric barrier discharges
Cylindrospermopsin (CYN) is an important cyanobacterial toxin posing a major threat to surface waters during cyanobacterial blooms. Hence, methods for cyanotoxin removal are required to confront seasonal or local incidences to sustain the safety of potable water reservoirs. Non-thermal plasmas provide the possibility for an environmentally benign treatment which can be adapted to specific concentrations and environmental conditions without the need of additional chemicals. We therefore investigated the potential of two different non-thermal plasma approaches for CYN degradation, operated either in a water mist, i.e. in air, or submerged in water. A degradation efficacy of 0.03 +/- 0.00 g kWh(-1) L-1 was found for a dielectric barrier discharge (DBD) operated in air, while a submerged pulsed corona-like discharge resulted in an efficacy of 0.24 +/- 0.02 g kWh(-1) L-1. CYN degradation followed a pseudo zeroth order or pseudo first order reaction kinetic, respectively. Treatment efficacy of the corona-like discharge submerged in water increased with pH values of the initial solution changing from 5.0 to 7.5. Notably, a pH-depending residual oxidative effect was observed for the submerged discharge, resulting in ongoing CYN degradation, even without further plasma treatment. In this case hydroxyl radicals were identified as the dominant oxidants of CYN at acidic pH values. In comparison, degradation by the DBD could be related primarily to the generation of ozone
The Planetary Fourier Spectrometer (PFS) onboard the European Mars Express mission
International audience; The Planetary Fourier Spectrometer (PFS) for the Mars Express mission is an infrared spectrometer optimised for atmospheric studies. This instrument has a short wave (SW) channel that covers the spectral range from 1700 to 8200.0cm-1 (1.2- 5.5mum) and a long-wave (LW) channel that covers 250- 1700cm-1 (5.5- 45mum). Both channels have a uniform spectral resolution of 1.3cm-1. The instrument field of view FOV is about 1.6o (FWHM) for the Short Wavelength channel (SW) and 2.8o (FWHM) for the Long Wavelength channel (LW) which corresponds to a spatial resolution of 7 and 12 km when Mars is observed from an height of 250 km. PFS can provide unique data necessary to improve our knowledge not only of the atmosphere properties but also about mineralogical composition of the surface and the surface-atmosphere interaction. The SW channel uses a PbSe detector cooled to 200-220 K while the LW channel is based on a pyroelectric ( LiTaO3) detector working at room temperature. The intensity of the interferogram is measured every 150 nm of physical mirrors displacement, corresponding to 600 nm optical path difference, by using a laser diode monochromatic light interferogram (a sine wave), whose zero crossings control the double pendulum motion. PFS works primarily around the pericentre of the orbit, only occasionally observing Mars from large distances. Each measurements take 4 s, with a repetition time of 8.5 s. By working roughly 0.6 h around pericentre, a total of 330 measurements per orbit will be acquired 270 looking at Mars and 60 for calibrations. PFS is able to take measurements at all local times, facilitating the retrieval of surface temperatures and atmospheric vertical temperature profiles on both the day and the night side
Development of a High Intensity Neutron Source at the European Spallation Source: The HighNESS project
The European Spallation Source (ESS), presently under construction in Lund,
Sweden, is a multidisciplinary international laboratory that will operate the
world's most powerful pulsed neutron source. Supported by a 3M Euro Research
and Innovation Action within the EU Horizon 2020 program, a design study
(HighNESS) is now underway to develop a second neutron source below the
spallation target. Compared to the first source, located above the spallation
target and designed for high cold and thermal brightness, the new source will
provide higher intensity, and a shift to longer wavelengths in the spectral
regions of cold (2 /- 20 {\AA}), very cold (VCN, 10 /- 120 {\AA}), and ultra
cold (UCN, > 500 {\AA}) neutrons. The core of the second source will consist of
a large liquid deuterium moderator to deliver a high flux of cold neutrons and
to serve secondary VCN and UCN sources, for which different options are under
study. The features of these new sources will boost several areas of condensed
matter research and will provide unique opportunities in fundamental physics.
Part of the HighNESS project is also dedicated to the development of future
instruments that will make use of the new source and will complement the
initial suite of instruments in construction at ESS. The HighNESS project
started in October 2020. In this paper, the ongoing developments and the
results obtained in the first year are described.Comment: 10 pages, 10 figures, 14th International Topical Meeting on Nuclear
Applications of Accelerators, November 30 to December 4, 2021, Washington, D
A chemical survey of exoplanets with ARIEL
Thousands of exoplanets have now been discovered with a huge range of masses, sizes and orbits: from rocky Earth-like planets to large gas giants grazing the surface of their host star. However, the essential nature of these exoplanets remains largely mysterious: there is no known, discernible pattern linking the presence, size, or orbital parameters of a planet to the nature of its parent star. We have little idea whether the chemistry of a planet is linked to its formation environment, or whether the type of host star drives the physics and chemistry of the planetâs birth, and evolution. ARIEL was conceived to observe a large number (~1000) of transiting planets for statistical understanding, including gas giants, Neptunes, super-Earths and Earth-size planets around a range of host star types using transit spectroscopy in the 1.25â7.8 ÎŒm spectral range and multiple narrow-band photometry in the optical. ARIEL will focus on warm and hot planets to take advantage of their well-mixed atmospheres which should show minimal condensation and sequestration of high-Z materials compared to their colder Solar System siblings. Said warm and hot atmospheres are expected to be more representative of the planetary bulk composition. Observations of these warm/hot exoplanets, and in particular of their elemental composition (especially C, O, N, S, Si), will allow the understanding of the early stages of planetary and atmospheric formation during the nebular phase and the following few million years. ARIEL will thus provide a representative picture of the chemical nature of the exoplanets and relate this directly to the type and chemical environment of the host star. ARIEL is designed as a dedicated survey mission for combined-light spectroscopy, capable of observing a large and well-defined planet sample within its 4-year mission lifetime. Transit, eclipse and phase-curve spectroscopy methods, whereby the signal from the star and planet are differentiated using knowledge of the planetary ephemerides, allow us to measure atmospheric signals from the planet at levels of 10â100 part per million (ppm) relative to the star and, given the bright nature of targets, also allows more sophisticated techniques, such as eclipse mapping, to give a deeper insight into the nature of the atmosphere. These types of observations require a stable payload and satellite platform with broad, instantaneous wavelength coverage to detect many molecular species, probe the thermal structure, identify clouds and monitor the stellar activity. The wavelength range proposed covers all the expected major atmospheric gases from e.g. H2O, CO2, CH4 NH3, HCN, H2S through to the more exotic metallic compounds, such as TiO, VO, and condensed species. Simulations of ARIEL performance in conducting exoplanet surveys have been performed â using conservative estimates of mission performance and a full model of all significant noise sources in the measurement â using a list of potential ARIEL targets that incorporates the latest available exoplanet statistics. The conclusion at the end of the Phase A study, is that ARIEL â in line with the stated mission objectives â will be able to observe about 1000 exoplanets depending on the details of the adopted survey strategy, thus confirming the feasibility of the main science objectives.Peer reviewedFinal Published versio
The Development of the NNBAR Experiment
The NNBAR experiment for the European Spallation Source will search for free
neutrons converting to antineutrons with a sensitivity improvement of three
orders of magnitude compared to the last such search. This paper describes
progress towards a conceptual design report for NNBAR. The design of a
moderator, neutron reflector, beamline, shielding and annihilation detector is
reported. The simulations used form part of a model which will be used for
optimisation of the experiment design and quantification of its sensitivity.Comment: 30 pages, 26 figures, accepted for publication in Journal of
Instrumentation (JINST
- âŠ