18 research outputs found

    Probing neutrino masses with CMB lensing extraction

    Get PDF
    We evaluate the ability of future cosmic microwave background (CMB) experiments to measure the power spectrum of large scale structure using quadratic estimators of the weak lensing deflection field. We calculate the sensitivity of upcoming CMB experiments such as BICEP, QUaD, BRAIN, ClOVER and PLANCK to the non-zero total neutrino mass M_nu indicated by current neutrino oscillation data. We find that these experiments greatly benefit from lensing extraction techniques, improving their one-sigma sensitivity to M_nu by a factor of order four. The combination of data from PLANCK and the SAMPAN mini-satellite project would lead to sigma(M_nu) = 0.1 eV, while a value as small as sigma(M_nu) = 0.035 eV is within the reach of a space mission based on bolometers with a passively cooled 3-4 m aperture telescope, representative of the most ambitious projects currently under investigation. We show that our results are robust not only considering possible difficulties in subtracting astrophysical foregrounds from the primary CMB signal but also when the minimal cosmological model (Lambda Mixed Dark Matter) is generalized in order to include a possible scalar tilt running, a constant equation of state parameter for the dark energy and/or extra relativistic degrees of freedom.Comment: 13 pages, 4 figures. One new figure and references added. Version accepted for publicatio

    Detection chain and electronic readout of the QUBIC instrument

    Get PDF
    The Q and U Bolometric Interferometer for Cosmology (QUBIC) Technical Demonstrator (TD) aiming to shows the feasibility of the combination of interferometry and bolometric detection. The electronic readout system is based on an array of 128 NbSi Transition Edge Sensors cooled at 350mK readout with 128 SQUIDs at 1K controlled and amplified by an Application Specific Integrated Circuit at 40K. This readout design allows a 128:1 Time Domain Multiplexing. We report the design and the performance of the detection chain in this paper. The technological demonstrator unwent a campaign of test in the lab. Evaluation of the QUBIC bolometers and readout electronics includes the measurement of I-V curves, time constant and the Noise Equivalent Power. Currently the mean Noise Equivalent Power is ~ 2 x 10⁻Âč⁶ W/√Hz

    Detection chain and electronic readout of the QUBIC instrument

    Get PDF
    The Q and U Bolometric Interferometer for Cosmology (QUBIC) Technical Demonstrator (TD) aiming to shows the feasibility of the combination of interferometry and bolometric detection. The electronic readout system is based on an array of 128 NbSi Transition Edge Sensors cooled at 350mK readout with 128 SQUIDs at 1K controlled and amplified by an Application Specific Integrated Circuit at 40K. This readout design allows a 128:1 Time Domain Multiplexing. We report the design and the performance of the detection chain in this paper. The technological demonstrator unwent a campaign of test in the lab. Evaluation of the QUBIC bolometers and readout electronics includes the measurement of I-V curves, time constant and the Noise Equivalent Power. Currently the mean Noise Equivalent Power is ~ 2 x 10⁻Âč⁶ W/√Hz

    The Planck milestone

    No full text
    International audiencePlanck, a European Space Agency satellite to be launched in 2007, is dedicated to surveying the full sky at sub-millimetre and millimetre wavelength. The primary goal of the mission is the final mapping of the Cosmic Microwave Background Anisotropies (CMBA). With an angular resolution of 5 arcmin and a sensitivity of Δ TCMB/ TCMB=2×10 -6, the Planck mission will be about 1000 times more sensitive than COBE-DMR and at least 20 times more than WMAP. Planck has also very good capabilites for measurements of polarization, although it will not exhaust the information contained in the CMBA polarization pattern. Two instruments share the Planck focal plane; the High Frequency Instrument (HFI) covers the wavelength ranging from 300 ÎŒm to 3 mm by using 48 bolometers cooled to 100 mK. This instrument is realized by an international collaboration, led by the IAS at Orsay. The other part of the relevant electromagnetic spectrum is covered by the Low Frequency Instrument (LFI) using HEMT radiometers cooled at 18 K and realized by a consortium led by the CNR in Milano. The first part of this article presents expected results of Planck on CMBA, both in intensity and polarization. In a second part, the global design of the Planck mission will be presented. We describe in particular the implications of Planck scientific goals on the instruments design, and especially on HFI that is the most sensitive Planck instrument. To cite this article: F.R. Bouchet et al., C. R. Physique 4 (2003)

    Planck-HFI thermal architecture: From requirements to solutions

    Get PDF
    The Planck-High Frequency Instrument (HFI) will use 48 bolometers cooled to 100mK by a dilution cooler to map the Cosmic Microwave Background (CMB) with a sensitivity of ΔT/T~2.10-6 and an angular resolution of 5 minutes of arc. This instrument will therefore be about 1000 times more sensitive than the COBE-DMR experiment. This contribution will focus mainly on the thermal architecture of this instrument and its consequences on the fundamental and instrumental fluctuations of the photon flux produced on the detectors by the instrument itself. In a first step, we will demonstrate that the thermal and optical design of the HFI allow to reach the ultimate sensitivity set by photon noise of the CMB at millimeter wavelength. Nevertheless, to reach such high sensitivity, the thermal behavior of each cryogenic stages should also be controlled in order to damp thermal fluctuations that can be taken as astrophysical signal. The requirement in thermal fluctuation on each stage has been defined in the frequency domain to degrade the overall sensitivity by less than 5%. This leads to unprecedented stability specifications that should be achieved down to 16mHz. We will present the design of the HFI thermal architecture, based on active and passive damping, and show how its performances were improved thanks to thermal simulations

    The Planck High Frequency Instrument, a third generation CMB probe and the first submillimeter surveyor

    Get PDF
    The High Frequency Instrument of the Planck satellite is dedicated to the measurement of the anisotropy of the Cosmic Microwave Background (CMB). Its main goal is to map the CMB with a sensitivity of ΔT/T=2.10-6 and an angular resolution of 5 arcmin in order to constrain cosmological parameters. Planck is a project of the European Space Agency based on a wide international collaboration, including United States and Canadian laboratories. The architecture of the satellite is driven by the thermal requirements resulting from the search for low photon noise. Especially, the passively cooled telescope should be at less than 50K, while a cascade of cryo-coolers will ensure the cooling of the HFI bolometers down to 0.1K. This last temperature will be produced by a gravity insensitive 3He/4He dilution cooler. This will be achieved at the L2 Lagrangian point of the Sun-Earth system. The whole sky will be observed two times in the 14 months mission with a scanning strategy based on a 1RPM rotation of the satellite. In addition to the cosmological parameters that can be derived from the CMB maps, Planck will deliver nine high sensitivity submillimeter maps of the whole sky that will constitute unique data available to the whole astronomical community

    Next generation sub-millimetre wave focal plane array coupling concepts: an ESA TRP project to develop multichroic focal plane pixels for future CMB polarisation experiments

    No full text
    International audienceIn this activity, we develop novel focal plane detector pixels for the next generation CMB B mode detection missions. Such future mission designs will require focal plane pixel technologies that optimizes the coupling from telescope optics to the large number of detectors required to reach the sensitivities required to measure the faint CMB polarization traces. As part of an ESA Technical Research Programme (TRP) programme we are tasked with developing, manufacturing and experimentally verifying a prototype multichroic pixel which would be suitable for the large focal plane arrays to reduce the focal plane size requirement. The concept of replacing traditional single channel pixels with multi frequency pixels will be a key driver in future mission design and the ability to couple radiation effectively over larger bandwidths (30 - 100%) is a real technical challenge. In the initial part of the programme we reviewed the science drivers and this determined the technical specifications of the mission. Various options for focal plane architectures were considered and then after a tradeoff study and review of resources available, a pixel demonstrator was selected for design manufacture and test. The chosen design consists of a novel planar mesh lens coupling to various planar antenna configurations with Resonant Cold Electron Bolometer (RCEB) for filtering and detection of the dual frequency signal. The final cryogenic tests are currently underway and a final performance will be verified for this pixel geometry

    PRISM (Polarized Radiation Imaging and Spectroscopy Mission): an extended white paper

    Get PDF
    Contains fulltext : 126057.pdf (preprint version ) (Open Access
    corecore