139 research outputs found

    A coded aperture microscope for X-ray fluorescence full-field imaging

    Get PDF
    The design and construction of an instrument for full-field imaging of the X-ray fluorescence emitted by a fully illuminated sample are presented. The aim is to produce an X-ray microscope with a few micrometers spatial resolution, which does not need to scan the sample. Since the fluorescence from a spatially inhomogeneous sample may contain many fluorescence lines, the optic which will provide the magnification of the emissions must be achromatic, i.e. its optical properties must be energy-independent. The only optics which fulfill this requirement in the X-ray regime are mirrors and pinholes. The throughput of a simple pinhole is very low, so the concept of coded apertures is an attractive extension which improves the throughput by having many pinholes, and retains the achromatic property. Modified uniformly redundant arrays (MURAs) with 10 mu m openings and 50% open area have been fabricated using gold in a lithographic technique, fabricated on a 1 mu m-thick silicon nitride membrane. The gold is 25 mu m thick, offering good contrast up to 20keV. The silicon nitride is transparent down into the soft X-ray region. MURAs with various orders, from 19 up to 73, as well as their respective negative (a mask where open and closed positions are inversed compared with the original mask), have been made. Having both signs of mask will reduce near-field artifacts and make it possible to correct for any lack of contrast

    An argument for the use of Aristotelian method in bioethics

    Get PDF
    The main claim of this paper is that the method outlined and used in Aristotle's Ethics is an appropriate and credible one to use in bioethics. Here “appropriate” means that the method is capable of establishing claims and developing concepts in bioethics and “credible” that the method has some plausibility, it is not open to obvious and immediate objection. It begins by suggesting why this claim matters and then gives a brief outline of Aristotle's method. The main argument is made in three stages. First, it is argued that Aristotelian method is credible because it compares favourably with alternatives. In this section it is shown that Aristotelian method is not vulnerable to criticisms that are made both of methods that give a primary place to moral theory (such as utilitarianism) and those that eschew moral theory (such as casuistry and social science approaches). As such, it compares favourably with these other approaches that are vulnerable to at least some of these criticisms. Second, the appropriateness of Aristotelian method is indicated through outlining how it would deal with a particular case. Finally, it is argued that the success of Aristotle's philosophy is suggestive of both the credibility and appropriateness of his method.</p

    Why Moral Expertise Needs Moral Theory

    Get PDF
    Discussions of the nature or possibility of moral expertise have largely proceeded in atheoretical terms, with little attention paid to whether moral expertise depends on theoretical knowledge of morality. Here I argue that moral expertise is more theory-dependent than is commonly recognized: Moral expertise consists, at least in part, in knowledge of the correct or best moral theory, and second, that knowledge of moral theory is essential to moral experts dispensing expert counsel to non-experts. Moral experts would not be moral experts absent knowledge of moral theory, nor could they play the testimonial role we would expect them to play in moral inquiry and deliberation absent such knowledg

    The Maia detector array and x-ray fluorescence imaging system: Locating rare precious metal phases in complex samples

    Get PDF
    X-ray fluorescence images acquired using the Maia large solid-angle detector array and integrated real-time processor on the X-ray Fluorescence Microscopy (XFM) beamline at the Australian Synchrotron capture fine detail in complex natural samples with images beyond 100M pixels. Quantitative methods permit real-time display of deconvoluted element images and for the acquisition of large area XFM images and 3D datasets for fluorescence tomography and chemical state (XANES) imaging. This paper outlines the Maia system and analytical methods and describes the use of the large detector array, with a wide range of X-ray take-off angles, to provide sensitivity to the depth of features, which is used to provide an imaging depth contrast and to determine the depth of rare precious metal particles in complex geological samples. © 2013 SPIE

    LSST: from Science Drivers to Reference Design and Anticipated Data Products

    Get PDF
    (Abridged) We describe here the most ambitious survey currently planned in the optical, the Large Synoptic Survey Telescope (LSST). A vast array of science will be enabled by a single wide-deep-fast sky survey, and LSST will have unique survey capability in the faint time domain. The LSST design is driven by four main science themes: probing dark energy and dark matter, taking an inventory of the Solar System, exploring the transient optical sky, and mapping the Milky Way. LSST will be a wide-field ground-based system sited at Cerro Pach\'{o}n in northern Chile. The telescope will have an 8.4 m (6.5 m effective) primary mirror, a 9.6 deg2^2 field of view, and a 3.2 Gigapixel camera. The standard observing sequence will consist of pairs of 15-second exposures in a given field, with two such visits in each pointing in a given night. With these repeats, the LSST system is capable of imaging about 10,000 square degrees of sky in a single filter in three nights. The typical 5σ\sigma point-source depth in a single visit in rr will be ∌24.5\sim 24.5 (AB). The project is in the construction phase and will begin regular survey operations by 2022. The survey area will be contained within 30,000 deg2^2 with ÎŽ<+34.5∘\delta<+34.5^\circ, and will be imaged multiple times in six bands, ugrizyugrizy, covering the wavelength range 320--1050 nm. About 90\% of the observing time will be devoted to a deep-wide-fast survey mode which will uniformly observe a 18,000 deg2^2 region about 800 times (summed over all six bands) during the anticipated 10 years of operations, and yield a coadded map to r∌27.5r\sim27.5. The remaining 10\% of the observing time will be allocated to projects such as a Very Deep and Fast time domain survey. The goal is to make LSST data products, including a relational database of about 32 trillion observations of 40 billion objects, available to the public and scientists around the world.Comment: 57 pages, 32 color figures, version with high-resolution figures available from https://www.lsst.org/overvie

    Just regionalisation: rehabilitating care for people with disabilities and chronic illnesses

    Get PDF
    BACKGROUND: Regionalised models of health care delivery have important implications for people with disabilities and chronic illnesses yet the ethical issues surrounding disability and regionalisation have not yet been explored. Although there is ethics-related research into disability and chronic illness, studies of regionalisation experiences, and research directed at improving health systems for these patient populations, to our knowledge these streams of research have not been brought together. Using the Canadian province of Ontario as a case study, we address this gap by examining the ethics of regionalisation and the implications for people with disabilities and chronic illnesses. The critical success factors we provide have broad applicability for guiding and/or evaluating new and existing regionalised health care strategies. DISCUSSION: Ontario is in the process of implementing fourteen Local Health Integration Networks (LHINs). The implementation of the LHINs provides a rare opportunity to address systematically the unmet diverse care needs of people with disabilities and chronic illnesses. The core of this paper provides a series of composite case vignettes illustrating integration opportunities relevant to these populations, namely: (i) rehabilitation and services for people with disabilities; (ii) chronic illness and cancer care; (iii) senior's health; (iv) community support services; (v) children's health; (vi) health promotion; and (vii) mental health and addiction services. For each vignette, we interpret the governing principles developed by the LHINs – equitable access based on patient need, preserving patient choice, responsiveness to local population health needs, shared accountability and patient-centred care – and describe how they apply. We then offer critical success factors to guide the LHINs in upholding these principles in response to the needs of people with disabilities and chronic illnesses. SUMMARY: This paper aims to bridge an important gap in the literature by examining the ethics of a new regionalisation strategy with a focus on the implications for people with disabilities and chronic illnesses across multiple sites of care. While Ontario is used as a case study to contextualize our discussion, the issues we identify, the ethical principles we apply, and the critical success factors we provide have broader applicability for guiding and evaluating the development of – or revisions to – a regionalised health care strategy

    Embedded pitch adapters: a high-yield interconnection solution for strip sensors

    Get PDF
    A proposal to fabricate large area strip sensors with integrated, or embedded, pitch adapters is presented for the End-cap part of the Inner Tracker in the ATLAS experiment. To implement the embedded pitch adapters, a second metal layer is used in the sensor fabrication, for signal routing to the ASICs. Sensors with different embedded pitch adapters have been fabricated in order to optimize the design and technology. Inter-strip capacitance, noise, pick-up, cross-talk, signal efficiency, and fabrication yield have been taken into account in their design and fabrication. Inter-strip capacitance tests taking into account all channel neighbors reveal the important differences between the various designs considered. These tests have been correlated with noise figures obtained in full assembled modules, showing that the tests performed on the bare sensors are a valid tool to estimate the final noise in the full module. The full modules have been subjected to test beam experiments in order to evaluate the incidence of cross-talk, pick-up, and signal loss. The detailed analysis shows no indication of cross-talk or pick-up as no additional hits can be observed in any channel not being hit by the beam above 170 mV threshold, and the signal in those channels is always below 1% of the signal recorded in the channel being hit, above 100 mV threshold. First results on irradiated mini-sensors with embedded pitch adapters do not show any change in the interstrip capacitance measurements with only the first neighbors connected

    Study of surface properties of ATLAS12 strip sensors and their radiation resistance

    Get PDF
    A radiation hard nĂŸ-in-p micro-strip sensor for the use in the Upgrade of the strip tracker of the ATLAS experiment at the High Luminosity Large Hadron Collider (HL-LHC) has been developed by the “ATLAS ITk Strip Sensor collaboration” and produced by Hamamatsu Photonics. Surface properties of different types of end-cap and barrel miniature sensors of the latest sensor design ATLAS12 have been studied before and after irradiation. The tested barrel sensors vary in “punchthrough protection” (PTP) structure, and the end-cap sensors, whose stereo-strips differ in fan geometry, in strip pitch and in edge strip ganging options. Sensors have been irradiated with proton fluences of up to 1 1016 neq/cm2 , by reactor neutron fluence of 1 1015 neq/cm2 and by gamma rays from 60Co up to dose of 1 MGy. The main goal of the present study is to characterize the leakage current for microdischarge breakdown voltage estimation, the inter-strip resistance and capacitance, the bias resistance and the effectiveness of PTP structures as a function of bias voltage and fluence. It has been verified that the ATLAS12 sensors have high breakdown voltage well above the operational voltage which implies that different geometries of sensors do not influence their stability. The inter-strip isolation is a strong function of irradiation fluence, however the sensor performance is acceptable in the expected range for HL-LHC. New gated PTP structure exhibits low PTP onset voltage and sharp cut-off of effective resistance even at the highest tested radiation fluence. The inter-strip capacitance complies with the technical specification required before irradiation and no radiation-induced degradation was observed. A summary of ATLAS12 sensors tests is presented including a comparison of results from different irradiation sites. The measured characteristics are compared with the previous prototype of the sensor design, ATLAS07
    • 

    corecore