112 research outputs found

    Proton imaging apparatus for protontherapy application

    Get PDF
    Radiotherapy with protons, due to the physical properties of these particles, offers several advantages for cancer therapy as compared to the traditional radiotherapy with photons. In the clinical use of proton beams, a pCT (proton Computed Tomography) apparatus can contribute to improve the accuracy of the patient positioning and dose distribution calculation. In this paper a pCT apparatus built by the PRIMA (PRoton IMAging) Italian Collaboration will be presented and the preliminary results will be discussed

    Data acquisition system for a proton imaging apparatus

    Get PDF
    New developments in the proton-therapy field for cancer treatments, leaded Italian physics researchers to realize a proton imaging apparatus consisting of a silicon microstrip tracker to reconstruct the proton trajectories and a calorimeter to measure their residual energy. For clinical requirements, the detectors used and the data acquisition system should be able to sustain about 1 MHz proton rate. The tracker read-out, using an ASICs developed by the collaboration, acquires the signals detector and sends data in parallel to an FPGA. The YAG:Ce calorimeter generates also the global trigger. The data acquisition system and the results obtained in the calibration phase are presented and discussed

    2D dosimeter based on monolithic silicon sensors for beam verification in conformal radiotherapy

    Get PDF
    Due to the features of modern radiotherapy techniques, such as Intensity Modulated Radiation Therapy (IMRT), Stereotactic Treatments with photons and proton therapy, where high spatial dose gradient are often present, detectors to be employed for two-dimensional dose verifications must satisfy narrow requirements. In particular, they have to exhibit high spatial resolution. For these applications, in the framework of the European Integrated project MAESTRO (LSHC-CT-2004-503564) and of the INFN experiment PRIMA, we designed a modular system based on a monolithic silicon segmented sensor. A single sensor has been coupled with readout electronics and tested with satisfactory results by using 6, 10 and 25MV X-rays from a LINAC at the University Hospital of Florence and 62MeV protons at INFN LNS Catania, following MAESTRO procedures. For photons, almost all the channels exhibit performances within project specifications (repeatability ≪0.5%, reproducibility ≪1%, deviation from linearity ≪1%, dose rate dependence ≪1%). For protons, the measured Spread Out Bragg Peak is in good agreement with the one measured with a single diode and the detector shows also a good linearity in the range 20–5000 cGy. The output factors are in agreement with those measured with ionization chamber, single diode or film, within experimental errors

    Bonding of the Inner Tracker Silicon Microstrip Modules

    Get PDF
    Microbonding of the CMS Tracker Inner Barrel (TIB) and Tracker Inner Disks (TID) modules was shared among six different Italian Institutes. The organization devised and the infrastructure deployed to handle this task is illustrated. Microbonding specifications and procedures for the different types of TIB and TID modules are given. The tooling specially designed and developed for these types of modules is described. Experience of production is presented. Attained production rates are given. An analysis of the microbonding quality achieved is presented, based on bond strengths measured in sample bond pull tests as well as on rates of bonding failures. Italian Bonding Centers routinely performed well above minimum specifications and a very low global introduced failure rate, at the strip level, of only \sim0.015 \% is observed

    Performance studies of the CMS strip tracker before installation

    Get PDF
    Peer reviewe

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe
    corecore