24 research outputs found

    Physical Properties and Lung Deposition of Particles Emitted from Five Major Indoor Sources

    Get PDF
    The physical properties of indoor particles were measured with an Scanning Mobility Particle Sizer (SMPS) system (14.6–850 nm), an Aerodynamic Particle Sizer (APS, 0.54–18 μm) and an Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA) in an apartment located in an urban background site in Prague (Czech Republic) from 15 August to 8 September, 2014. The total particle maximum number concentration was 9.38 × 10(4), 1.46 × 10(5), 2.89 × 10(4), 2.25 × 10(5) and 1.57 × 10(6) particles cm(−3) for particles released from vacuum cleaning, soap/W5 cleaning spray, smoking, incense burning and cooking (frying) activities, respectively. Particles emitted from cleaning activities showed unimodal number size distributions, with the majority of particles (>98.2 %) in the ultrafine size range (Dp <100 nm) and modes at a diameter of 19.8 nm for vacuum cleaning and 30.6 nm for soap/W5 cleaning. Smoking and incense burning predominantly generated particles in the accumulation mode with a count median diameter around 90–150 nm while cooking emissions showed a bimodal structure with a main mode at 47.8 nm. Particles from vacuum cleaning, incense burning, smoking and cooking emissions were found to be “nearly hydrophobic” with an average growth factor (G(f)) around 1.01–1.10, while particles emitted from desk cleaning using organic compounds were found to be “less-hygroscopic” (G(f) ∼1.12–1.16). Based on an adjusted MPPD model with a consideration of the hygroscopic properties of particles, the total lung deposition fractions of these particles by number when they penetrate into the human lung were 0.73 ± 0.02, 0.62 ± 0.03, 0.37 ± 0.03, 0.32 ± 0.03 and 0.49 ± 0.02 for vacuum cleaning, desk cleaning, smoking, incense burning and cooking, respectively

    Number Concentrations and Modal Structure of Indoor/Outdoor Fine Particles in Four European Cities

    Get PDF
    Indoor/outdoor aerosol size distribution was measured in four European cities (Oslo-Norway, Prague-Czech Republic, Milan-Italy and Athens-Greece) during 2002 in order to examine the differences in the characteristics of the indoor/outdoor modal structure and to evaluate the effect of indoor sources to the aerosol size distributions. All the measurement sites were naturally ventilated and were occupied during the campaigns by permanent residents or for certain time periods by the technical staff responsible for the instrumentation. Outdoor particle number (PN) concentrations presented the higher values in Milan and Athens (median values 1.4 x 10(4) # cm(-3) and 2.9 x 10(4) # cm(-3) respectively) as a result of elevated outdoor emissions and led to correspondingly higher indoor values compared to Oslo and Prague. In absence of indoor activities, the indoor concentrations followed the fluctuations of the outdoor concentrations in all the measurement sites. Indoor activities (cooking, smoking, etc.) resulted in elevated indoor PN concentrations (maximum values ranging between 1.7 x 10(5) # cm(-3) and 3.2 x 10(5) # cm(-3)) and to I/O ratios higher than one. The I/O ratios were size dependant and for periods without indoor activities, they presented the lowest values for particles <50 nm (0.51 +/- 0.15) and the ratios increased with fine particle size (0.79 +/- 0.12 for particles between 100-200 nm). The analysis of the modal structure showed that the indoor aerosol size distribution characteristics differ from the outdoors under the effect of indoor sources. The percentage of unimodal size distributions increased during indoor emissions, compared to periods without indoor sources, along with the number concentration of Aitken mode particles, indicating emissions in specific size ranges according to the type of the indoor source.Peer reviewe

    Lung-depositing surface area (LDSA) of particles in office spaces around Europe : Size distributions, I/O-ratios and infiltration

    Get PDF
    Air pollution, and specifically particulate matter pollution, is one of the greatest dangers to human health. Outdoor air pollution ranks third in causes for premature death. Improving indoor air quality is of immense importance, as the time spent indoors is often much greater than the time spent outdoors. In this experimental study, we evaluate the levels of particle pollution in indoor air in four offices across Europe, compare the indoor particles to outdoor particles and assess where the particles originate from. The measurements were conducted with an Electrical Low-Pressure Impactor (ELPI+) for particles between 6 nm and 1 μm. The chosen metric, lung-deposited particle surface area (LDSA), targets the health impacts of particle pollution. Based on the measurements, we determined that most of the indoor air particles infiltrated from outdoor air, although two of the offices had very limited indoor activity during the measurement campaigns and may not represent typical use. The highest median indoor LDSA concentration during daytime hours was 27.2 μm2/cm3, whereas the lowest was 2.8 μm2/cm3. Indoor air in general had lower LDSA concentrations than outdoor air, the corresponding outdoor LDSA concentrations being 35.8 μm2/cm3 and 9.8 μm2/cm3. The particle size ranges which contributed to the highest concentrations were 50–100 nm and 300–500 nm. These size ranges correspond to soot mode and accumulation mode particles, which represent local and regional sources, respectively. Based on this study, limiting particle infiltration is the key factor in keeping indoor air in offices free of lung-depositing particles.Peer reviewe

    Seasonality of the particle number concentration and size distribution : a global analysis retrieved from the network of Global Atmosphere Watch (GAW) near-surface observatories

    Get PDF
    Aerosol particles are a complex component of the atmospheric system which influence climate directly by interacting with solar radiation, and indirectly by contributing to cloud formation. The variety of their sources, as well as the multiple transformations they may undergo during their transport (including wet and dry deposition), result in significant spatial and temporal variability of their properties. Documenting this variability is essential to provide a proper representation of aerosols and cloud condensation nuclei (CCN) in climate models. Using measurements conducted in 2016 or 2017 at 62 ground-based stations around the world, this study provides the most up-to-date picture of the spatial distribution of particle number concentration (N-tot) and number size distribution (PNSD, from 39 sites). A sensitivity study was first performed to assess the impact of data availability on N-tot's annual and seasonal statistics, as well as on the analysis of its diel cycle. Thresholds of 50% and 60% were set at the seasonal and annual scale, respectively, for the study of the corresponding statistics, and a slightly higher coverage (75 %) was required to document the diel cycle. Although some observations are common to a majority of sites, the variety of environments characterizing these stations made it possible to highlight contrasting findings, which, among other factors, seem to be significantly related to the level of anthropogenic influence. The concentrations measured at polar sites are the lowest (similar to 10(2) cm(-3)) and show a clear seasonality, which is also visible in the shape of the PNSD, while diel cycles are in general less evident, due notably to the absence of a regular day-night cycle in some seasons. In contrast, the concentrations characteristic of urban environments are the highest (similar to 10(3)-10(4) cm(-3)) and do not show pronounced seasonal variations, whereas diel cycles tend to be very regular over the year at these stations. The remaining sites, including mountain and non-urban continental and coastal stations, do not exhibit as obvious common behaviour as polar and urban sites and display, on average, intermediate N-tot (similar to 10(2)-10(3) cm(-3)). Particle concentrations measured at mountain sites, however, are generally lower compared to nearby lowland sites, and tend to exhibit somewhat more pronounced seasonal variations as a likely result of the strong impact of the atmospheric boundary layer (ABL) influence in connection with the topography of the sites. ABL dynamics also likely contribute to the diel cycle of N-tot observed at these stations. Based on available PNSD measurements, CCN-sized particles (considered here as either >50 nm or >100 nm) can represent from a few percent to almost all of N-tot, corresponding to seasonal medians on the order of similar to 10 to 1000 cm(-3), with seasonal patterns and a hierarchy of the site types broadly similar to those observed for N-tot. Overall, this work illustrates the importance of in situ measurements, in particular for the study of aerosol physical properties, and thus strongly supports the development of a broad global network of near surface observatories to increase and homogenize the spatial coverage of the measurements, and guarantee as well data availability and quality. The results of this study also provide a valuable, freely available and easy to use support for model comparison and validation, with the ultimate goal of contributing to improvement of the representation of aerosol-cloud interactions in models, and, therefore, of the evaluation of the impact of aerosol particles on climate.Peer reviewe

    On foreclosure rates and the house price index: A cross-sectional analysis

    Get PDF
    This paper attempts to firmly establish the dependence of house price index on foreclosure rates, a prerequisite to substantiating “let-sink” foreclosure policy. In our paper, we first examine a simple linear regression model to show that there are omitted variables in the model, and therefore, more variables other than just foreclosure rates have to be considered. We then continue with the multiple linear regression model by looking at the influence of foreclosure rates, education, property tax, income tax, stimulus, and legal system upon house price index. By using this model, we show that most variables do not have statistical significance, individually or jointly, except for foreclosure rates and legal system. Finally, we reject the null hypothesis and conclude that house price index is significantly dependent upon foreclosure rates and the state legal foreclosure system

    Using Behavior Objects to Manage Complexity in Virtual Worlds

    No full text

    Internal Combustion Engines as the Main Source of Ultrafine Particles in Residential Neighborhoods: Field Measurements in the Czech Republic

    No full text
    Ultrafine particles (UFP, diameter &lt; 100 nm) exposure has already been associated with adverse effects on human health. Spatial distribution of UFP is non-uniform; they concentrate in the vicinity of the source, e.g. traffic, because of their short lifespan. This work investigates spatial distribution of UFP in three areas in the Czech Republic with different traffic load: High traffic (Prague neighborhood—Sporilov), commuter road vicinity (Libeznice), and a small city with only local traffic (Celakovice). Size-resolved measurements of particles in the 5–500 nm range were taken with a particle classifier mounted, along with batteries, GPS and other accessories, on a handcart and pushed around the areas, making one-minute or longer stops at places of interest. Concentrations along main roads were elevated in comparison with places farther from the road; this pattern was observed in all sites, while particle number distributions both close and away from main roads had similar patterns. The absence of larger particles, the relative absence of higher concentrations of particles away from the main roads, and similar number distributions suggest that high particle number concentrations cannot be readily attributed to sources other than internal combustion engines in vehicles and mobile machinery (i.e., mowers and construction machines)

    Vysoce kvalitní a snadno regenerovatelný osobní filtr

    No full text
    Proper respiratory tract protection is the key factor to limiting the rate of COVID-19 spread and providing a safe environment for health care workers. Traditional N95 (FFP2) respirators are not easy to regenerate and thus create certain financial and ecological burdens; moreover, their quality may vary significantly. A solution that would overcome these disadvantages is desirable. In this study a commercially available knit polyester fleece fabric was selected as the filter material, and a total of 25 filters of different areas and thicknesses were prepared. Then, the size-resolved filtration efficiency (40-400 nm) and pressure drop were evaluated at a volumetric flow rate of 95 L/min. We showed the excellent synergistic effect of expanding the filtration area and increasing the number of filtering layers on the filtration efficiency; a filter cartridge with 8 layers of knit polyester fabric with a surface area of 900 cm(2) and sized 25 x 14 x 8 cm achieved filtration efficiencies of 98% at 95 L/min and 99.5% at 30 L/min. The assembled filter kit consists of a filter cartridge (14 Pa) carried in a small backpack connected to a half mask with a total pressure drop of 84 Pa at 95 L/min. In addition, it is reusable, and the filter material can be regenerated at least ten times by simple methods, such as boiling. We have demonstrated a novel approach for creating high-quality and easy-to-breathe-through respiratory protective equipment that reduces operating costs and is a green solution because it is easy to regenerate.Správná ochrana dýchacích cest je klíčovým faktorem pro omezení rychlosti šíření COVID-19 a zajištění bezpečného prostředí pro zdravotnické pracovníky. Tradiční respirátory N95 (FFP2) se nedají snadno regenerovat a vytvářejí tak určitou finanční a ekologickou zátěž; navíc se jejich kvalita může výrazně lišit. Žádoucí je řešení, které by tyto nevýhody překonalo. V této studii byla jako filtrační materiál vybrána komerčně dostupná pletená polyesterová fleecová tkanina a bylo připraveno celkem 25 filtrů různých ploch a tlouštěk. Poté byla vyhodnocena účinnost filtrace s rozlišením velikosti (40-400 nm) a pokles tlaku při objemovém průtoku 95 l/min. Prokázali jsme vynikající synergický efekt rozšíření filtrační plochy a zvýšení počtu filtračních vrstev na účinnost filtrace; filtrační patrona s 8 vrstvami pletené polyesterové tkaniny o ploše 900 cm(2) a rozměrech 25 x 14 x 8 cm dosáhla účinnosti filtrace 98 % při 95 l/min a 99,5 % při 30 l/min. Sestavená filtrační sada se skládá z filtrační patrony (14 Pa) nesené v malém batohu spojeném s polomaskou s celkovým tlakovým spádem 84 Pa při 95 l/min. Navíc je opakovaně použitelný a filtrační materiál lze jednoduchými metodami, jako je vaření, nejméně desetkrát regenerovat. Prokázali jsme nový přístup k vytvoření vysoce kvalitních a snadno dýchatelných dýchacích ochranných prostředků, které snižují provozní náklady a jsou ekologickým řešením, protože se snadno regenerují
    corecore