101 research outputs found

    Determination of local material properties of OSB sample by coupling advanced imaging techniques and morphology-based FEM simulation

    Get PDF
    This is the publisher’s final pdf. The published article is copyrighted by Walter de Gruyter & Co. and can be found at: http://www.degruyter.com/.The goal was to determine local mechanical properties inside of oriented strand board (OSB) based on a realistic morphology-based finite element (FE) model and data acquired from a physical test performed on the same material. The spatial information and local grayscale intensity from CT-scans obtained from small OSB sample was transformed into a 2D regular morphology-based FE mesh with corresponding material properties. The model was then used to simulate the actual compression test performed on the specimen using simplified boundary conditions. The simulated strain fields from the model were compared with the actual strain field measured on the specimen surface during the compression test by means of a full-field optical method, named digital image correlation (DIC). Finally, the original set of material properties was adjusted by an iterative procedure to minimize the difference between the simulated and the measured strain data. The results show that the developed procedure is useful to find local material properties as well as for morphological modeling without the need of segmentation of the image data. The achieved results serve as a prerequisite for full 3D analyses of the complex materials

    A finite element based formulation for sensitivity studies of piezoelectric systems

    Get PDF
    Sensitivity Analysis is a branch of numerical analysis which aims to quantify the affects that variability in the parameters of a numerical model have on the model output. A finite element based sensitivity analysis formulation for piezoelectric media is developed here and implemented to simulate the operational and sensitivity characteristics of a piezoelectric based distributed mode actuator (DMA). The work acts as a starting point for robustness analysis in the DMA technology

    Utilizing FEM-Software to quantify pre- and post-interventional cardiac reconstruction data based on modelling data sets from surgical ventricular repair therapy (SVRT) and cardiac resynchronisation therapy (CRT)

    Get PDF
    BACKGROUND: Left ventricle (LV) 3D structural data can be easily obtained using standard transesophageal echocardiography (TEE) devices but quantitative pre- and intraoperative volumetry and geometry analysis of the LV is presently not feasible in the cardiac operation room (OR). Finite element method (FEM) modelling is necessary to carry out precise and individual volume analysis and in the future will form the basis for simulation of cardiac interventions. METHOD: A Philips/HP Sonos 5500 ultrasound device stores volume data as time-resolved 4D volume data sets. In this prospective study TomTec LV Analysis TEE(© )Software was used for semi-automatic endocardial border detection, reconstruction, and volume-rendering of the clinical 3D echocardiographic data. With the software FemCoGen(© )a quantification of partial volumes and surface directions of the LV was carried out for two patients data sets. One patient underwent surgical ventricular repair therapy (SVR) and the other a cardiac resynchronisation therapy (CRT). RESULTS: For both patients a detailed volume and surface direction analysis is provided. Partial volumes as well as normal directions to the LV surface are pre- and post-interventionally compared. CONCLUSION: The operation results for both patients are quantified. The quantification shows treatment details for both interventions (e.g. the elimination of the discontinuities for CRT intervention and the segments treated for SVR intervention). The LV quantification is feasible in the cardiac OR and it gives a detailed and immediate quantitative feedback of the quality of the intervention to the medical

    Mesh management methods in finite element simulations of orthodontic tooth movement

    Get PDF
    In finite element simulations of orthodontic tooth movement, one of the challenges is to represent long term tooth movement. Large deformation of the periodontal ligament and large tooth displacement due to bone remodelling lead to large distortions of the finite element mesh when a Lagrangian formalism is used. We propose in this work to use an Arbitrary Lagrangian Eulerian (ALE) formalism to delay remeshing operations. A large tooth displacement is obtained including effect of remodelling without the need of remeshing steps but keeping a good-quality mesh. Very large deformations in soft tissues such as the periodontal ligament is obtained using a combination of the ALE formalism used continuously and a remeshing algorithm used when needed. This work demonstrates that the ALE formalism is a very efficient way to delay remeshing operations

    Finite-element-method (FEM) model generation of time-resolved 3D echocardiographic geometry data for mitral-valve volumetry

    Get PDF
    INTRODUCTION: Mitral Valve (MV) 3D structural data can be easily obtained using standard transesophageal echocardiography (TEE) devices but quantitative pre- and intraoperative volume analysis of the MV is presently not feasible in the cardiac operation room (OR). Finite element method (FEM) modelling is necessary to carry out precise and individual volume analysis and in the future will form the basis for simulation of cardiac interventions. METHOD: With the present retrospective pilot study we describe a method to transfer MV geometric data to 3D Slicer 2 software, an open-source medical visualization and analysis software package. A newly developed software program (ROIExtract) allowed selection of a region-of-interest (ROI) from the TEE data and data transformation for use in 3D Slicer. FEM models for quantitative volumetric studies were generated. RESULTS: ROI selection permitted the visualization and calculations required to create a sequence of volume rendered models of the MV allowing time-based visualization of regional deformation. Quantitation of tissue volume, especially important in myxomatous degeneration can be carried out. Rendered volumes are shown in 3D as well as in time-resolved 4D animations. CONCLUSION: The visualization of the segmented MV may significantly enhance clinical interpretation. This method provides an infrastructure for the study of image guided assessment of clinical findings and surgical planning. For complete pre- and intraoperative 3D MV FEM analysis, three input elements are necessary: 1. time-gated, reality-based structural information, 2. continuous MV pressure and 3. instantaneous tissue elastance. The present process makes the first of these elements available. Volume defect analysis is essential to fully understand functional and geometrical dysfunction of but not limited to the valve. 3D Slicer was used for semi-automatic valve border detection and volume-rendering of clinical 3D echocardiographic data. FEM based models were also calculated. METHOD: A Philips/HP Sonos 5500 ultrasound device stores volume data as time-resolved 4D volume data sets. Data sets for three subjects were used. Since 3D Slicer does not process time-resolved data sets, we employed a standard movie maker to animate the individual time-based models and visualizations. Calculation time and model size were minimized. Pressures were also easily available. We speculate that calculation of instantaneous elastance may be possible using instantaneous pressure values and tissue deformation data derived from the animated FEM

    An overview of burst, buckling, durability and corrosion analysis of lightweight FRP composite pipes and their applicability

    Get PDF
    © 2019 Elsevier Ltd. All rights reserved.The main aim of this review article was to address the performance of filament wound fibre reinforced polymer (FRP) composite pipes and their critical properties, such as burst, buckling, durability and corrosion. The importance of process parameters concerning merits and demerits of the manufacturing methods was discussed for the better-quality performance. Burst analysis revealed that the winding angle of ±55° was observed to be optimum with minimum failure mechanisms, such as matrix cracking, whitening, leakage and fracture. The reduction of buckling effect was reported in case of lower hoop stress value in the hoop to axial stress ratio against axial, compression and torsion. A significant improvement in energy absorption was observed in the hybrid composite pipes with the effect of thermal treatment. However, the varying winding angle in FRP pipe fabrication was reported as an influencing factor affecting all the aforementioned properties. Almost 90% of the reviewed studies was done using E-glass/epoxy materials for the composite pipe production. By overcoming associated limitations, such as replacing synthetic materials, designing new material combinations and cost-benefit analysis, the production cost of the lightweight FRP composite pipes can be decreased for the real-time applications.Peer reviewe

    Chondrocyte Deformations as a Function of Tibiofemoral Joint Loading Predicted by a Generalized High-Throughput Pipeline of Multi-Scale Simulations

    Get PDF
    Cells of the musculoskeletal system are known to respond to mechanical loading and chondrocytes within the cartilage are not an exception. However, understanding how joint level loads relate to cell level deformations, e.g. in the cartilage, is not a straightforward task. In this study, a multi-scale analysis pipeline was implemented to post-process the results of a macro-scale finite element (FE) tibiofemoral joint model to provide joint mechanics based displacement boundary conditions to micro-scale cellular FE models of the cartilage, for the purpose of characterizing chondrocyte deformations in relation to tibiofemoral joint loading. It was possible to identify the load distribution within the knee among its tissue structures and ultimately within the cartilage among its extracellular matrix, pericellular environment and resident chondrocytes. Various cellular deformation metrics (aspect ratio change, volumetric strain, cellular effective strain and maximum shear strain) were calculated. To illustrate further utility of this multi-scale modeling pipeline, two micro-scale cartilage constructs were considered: an idealized single cell at the centroid of a 100×100×100 μm block commonly used in past research studies, and an anatomically based (11 cell model of the same volume) representation of the middle zone of tibiofemoral cartilage. In both cases, chondrocytes experienced amplified deformations compared to those at the macro-scale, predicted by simulating one body weight compressive loading on the tibiofemoral joint. In the 11 cell case, all cells experienced less deformation than the single cell case, and also exhibited a larger variance in deformation compared to other cells residing in the same block. The coupling method proved to be highly scalable due to micro-scale model independence that allowed for exploitation of distributed memory computing architecture. The method’s generalized nature also allows for substitution of any macro-scale and/or micro-scale model providing application for other multi-scale continuum mechanics problems
    • …
    corecore