1,461 research outputs found

    The central image of a gravitationally lensed quasar

    Full text link
    A galaxy can act as a gravitational lens, producing multiple images of a background object. Theory predicts there should be an odd number of images but, paradoxically, almost all observed lenses have 2 or 4 images. The missing image should be faint and appear near the galaxy's center. These ``central images'' have long been sought as probes of galactic cores too distant to resolve with ordinary observations. There are five candidates, but in one case the third image is not necessarily a central image, and in the others, the central component might be a foreground source rather than a lensed image. Here we report the most secure identification of a central image, based on radio observations of PMN J1632-0033, one of the latter candidates. Lens models incorporating the central image show that the mass of the lens galaxy's central black hole is less than 2 x 10^8 M_sun, and the galaxy's surface density at the location of the central image is more than 20,000 M_sun per square parsec, in agreement with expectations based on observations of galaxies hundreds of times closer to the Earth.Comment: Nature, in press [7 pp, 2 figs]. Standard media embargo applies before publicatio

    Application of light microscopical and ultrastructural immunohistochemistry in the study of goblet cell carcinoid in the appendix

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Goblet cell carcinoids appear less frequently in the appendix than do other carcinoids. In the presented work a case with a goblet cell carcinoid of the appendix is described.</p> <p>Methods</p> <p>Routine histological and histochemical methods were employed, with a combination of histochemistry and immunohistochemistry on one section and light and electron microscopical immunohistochemisty on paraffin-embedded material, were applied to identify the type of the carcinoid and to reveal the fine structure of cell types in the tumour nests of the appendix.</p> <p>Results</p> <p>During the biopsy of a patient who had undergone appendectomy, an infiltration with clusters of goblet cells in the submucosa of the appendix was found. After a second operation of right-sided hemicolectomy, similar clusters of goblet cells were detected in the muscle layers of the caecum. After 18 months the patient died from cirrhosis and had not developed metastases or any recurrence. Immunohistochemically the serotonin-, somatostatin-, chromogranin A- and synaptophysin-positive endocrine cells were basally attached to mucin-secreting cells. The combined staining revealed simultaneously present endocrine cells (chromogranin-A-positive) and mucin-secreting cells (PAS- or alcian blue-positive). The ultrastructural immunohistochemistry showed that chromogranin A-positive cells had discoid and pleomorphic granules and were located in tumour nests or as single cells in the appendiceal wall.</p> <p>Conclusion</p> <p>The combined histochemical and immunohistochemical procedure and the ultrastructural immunohistochemistry on archival material could contribute in clarifying the diagnosis of goblet cell carcinoid.</p

    Quadriceps force generation in patients with osteoarthritis of the knee and asymptomatic participants during patellar tendon reflex reactions: an exploratory cross-sectional study

    Get PDF
    BACKGROUND: It has been postulated that muscle contraction is slower in patients with osteoarthritis of the knee than asymptomatic individuals, a factor that could theoretically impair joint protection mechanisms. This study investigated whether patients with osteoarthritis of the knee took longer than asymptomatic participants to generate force during reflex quadriceps muscle contraction. This was an exploratory study to inform sample size for future studies. METHODS: An exploratory observational cross sectional study was carried out. Two subject groups were tested, asymptomatic participants (n = 17), mean (SD) 56.7 (8.6) years, and patients with osteoarthritis of the knee, diagnosed by an orthopaedic surgeon, (n = 16), age 65.9 (7.8) years. Patellar tendon reflex responses were elicited from participants and measured with a load cell. Force latency, contraction time, and force of the reflex response were determined from digitally stored data. The Mann-Whitney U test was used for the between group comparisons in these variables. Bland and Altman within-subject standard deviation values were calculated to evaluate the measurement error or precision of force latency and contraction time. RESULTS: No significant differences were found between the groups for force latency (p = 0.47), contraction time (p = 0.91), or force (p = 0.72). The two standard deviation measurement error values for force latency were 27.9 ms for asymptomatic participants and 16.4 ms for OA knee patients. For contraction time, these values were 29.3 ms for asymptomatic participants and 28.1 ms for OA knee patients. Post hoc calculations revealed that the study was adequately powered (80%) to detect a difference between the groups of 30 ms in force latency. However it was inadequately powered (59%) to detect this same difference in contraction time, and 28 participants would be required in each group to reach 80% power. CONCLUSION: Patients with osteoarthritis of the knee do not appear to have compromised temporal parameters or magnitude of force generation during patellar tendon reflex reactions when compared to a group of asymptomatic participants. However, these results suggest that larger studies are carried out to investigate this area further

    The Neurotoxicity of DOPAL: Behavioral and Stereological Evidence for Its Role in Parkinson Disease Pathogenesis

    Get PDF
    BACKGROUND: The etiology of Parkinson disease (PD) has yet to be fully elucidated. We examined the consequences of injections of 3,4-dihydroxyphenylacetaldehyde (DOPAL), a toxic metabolite of dopamine, into the substantia nigra of rats on motor behavior and neuronal survival. METHODS/PRINCIPAL FINDINGS: A total of 800 nl/rat of DOPAL (1 µg/200 nl) was injected stereotaxically into the substantia nigra over three sites while control animals received similar injections of phosphate buffered saline. Rotational behavior of these rats was analyzed, optical density of striatal tyrosine hydroxylase was calculated, and unbiased stereological counts of the substantia nigra were made. The rats showed significant rotational asymmetry ipsilateral to the lesion, supporting disruption of dopaminergic nigrostriatal projections. Such disruption was verified since the density of striatal tyrosine hydroxylase decreased significantly (p<0.001) on the side ipsilateral to the DOPAL injections when compared to the non-injected side. Stereological counts of neurons stained for Nissl in pars compacta of the substantia nigra significantly decreased (p<0.001) from control values, while counts of those in pars reticulata were unchanged after DOPAL injections. Counts of neurons immunostained for tyrosine hydroxylase also showed a significant (p=0.032) loss of dopaminergic neurons. In spite of significant loss of dopaminergic neurons, DOPAL injections did not induce significant glial reaction in the substantia nigra. CONCLUSIONS: The present study provides the first in vivo quantification of substantia nigra pars compacta neuronal loss after injection of the endogenous toxin DOPAL. The results demonstrate that injections of DOPAL selectively kills SN DA neurons, suggests loss of striatal DA terminals, spares non-dopaminergic neurons of the pars reticulata, and triggers a behavioral phenotype (rotational asymmetry) consistent with other PD animal models. This study supports the "catecholaldehyde hypothesis" as an important link for the etiology of sporadic PD

    Search for rare quark-annihilation decays, B --> Ds(*) Phi

    Full text link
    We report on searches for B- --> Ds- Phi and B- --> Ds*- Phi. In the context of the Standard Model, these decays are expected to be highly suppressed since they proceed through annihilation of the b and u-bar quarks in the B- meson. Our results are based on 234 million Upsilon(4S) --> B Bbar decays collected with the BABAR detector at SLAC. We find no evidence for these decays, and we set Bayesian 90% confidence level upper limits on the branching fractions BF(B- --> Ds- Phi) Ds*- Phi)<1.2x10^(-5). These results are consistent with Standard Model expectations.Comment: 8 pages, 3 postscript figues, submitted to Phys. Rev. D (Rapid Communications

    A Systematic Review of Fitness Apps and Their Potential Clinical and Sports Utility for Objective and Remote Assessment of Cardiorespiratory Fitness

    Get PDF
    Key Points The validity and reliability of existing and/or underdevelopment fitness apps should be further investigated. Physiological signals should be incorporated into fitness apps, such as heart rate measures using a smartphone camera, during or after exercise testing. There is a need to develop interoperable fitness apps (e.g., different languages, apps integrated into both app markets, data that is device-independent). Fitness apps should incorporate evidence-based cutpoints of CRF, allowing interpretation of fitness testing resultsWe are grateful to Ms Carmen Sainz-Quinn for assistance with the English language.Background Cardiorespiratory fitness (CRF) assessment provides key information regarding general health status that has high clinical utility. In addition, in the sports setting, CRF testing is needed to establish a baseline level, prescribe an individualized training program and monitor improvement in athletic performance. As such, the assessment of CRF has both clinical and sports utility. Technological advancements have led to increased digitization within healthcare and athletics. Nevertheless, further investigation is needed to enhance the validity and reliability of existing fitness apps for CRF assessment in both contexts. Objectives The present review aimed to (1) systematically review the scientific literature, examining the validity and reliability of apps designed for CRF assessment; and (2) systematically review and qualitatively score available fitness apps in the two main app markets. Lastly, this systematic review outlines evidence-based practical recommendations for developing future apps that measure CRF. Data Sources The following sources were searched for relevant studies: PubMed, Web of Science®, ScopusTM, and SPORTDiscus, and data was also found within app markets (Google Play and the App Store). Study Eligibility Criteria Eligible scientific studies examined the validity and/or reliability of apps for assessing CRF through a field-based fitness test. Criteria for the app markets involved apps that estimated CRF. Study Appraisal and Synthesis Methods The scientific literature search included four major electronic databases and the timeframe was set between 01 January 2000 and 31 October 2018. A total of 2796 articles were identified using a set of fitness-related terms, of which five articles were finally selected and included in this review. The app market search was undertaken by introducing keywords into the search engine of each app market without specified search categories. A total of 691 apps were identified using a set of fitness-related terms, of which 88 apps were finally included in the quantitative and qualitative synthesis. Results Five studies focused on the scientific validity of fitness tests with apps, while only two of these focused on reliability. Four studies used a sub-maximal fitness test via apps. Out of the scientific apps reviewed, the SA-6MWTapp showed the best validity against a criterion measure (r = 0.88), whilst the InterWalk app showed the highest test–retest reliability (ICC range 0.85–0.86). Limitations Levels of evidence based on scientific validity/reliability of apps and on commercial apps could not be robustly determined due to the limited number of studies identified in the literature and the low-to-moderate quality of commercial apps. Conclusions The results from this scientific review showed that few apps have been empirically tested, and among those that have, not all were valid or reliable. In addition, commercial apps were of low-to-moderate quality, suggesting that their potential for assessing CRF has yet to be realized. Lastly, this manuscript has identified evidence-based practical recommendations that apps might potentially offer to objectively and remotely assess CRF as a complementary tool to traditional methods in the clinical and sports settings

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Search for the neutral Higgs bosons of the minimal supersymmetric standard model in pp collisions at root s=7 TeV with the ATLAS detector

    Get PDF
    A search for neutral Higgs bosons of the Minimal Supersymmetric Standard Model (MSSM) is reported. The analysis is based on a sample of proton-proton collisions at a centre-of-mass energy of 7TeV recorded with the ATLAS detector at the Large Hadron Collider. The data were recorded in 2011 and correspond to an integrated luminosity of 4.7 fb-1 to 4.8 fb-1. Higgs boson decays into oppositely-charged muon or τ lepton pairs are considered for final states requiring either the presence or absence of b-jets. No statistically significant excess over the expected background is observed and exclusion limits at the 95% confidence level are derived. The exclusion limits are for the production cross-section of a generic neutral Higgs boson, φ, as a function of the Higgs boson mass and for h/A/H production in the MSSM as a function of the parameters mA and tan β in the mhmax scenario for mA in the range of 90GeV to 500 GeV. Copyright CERN
    corecore