7 research outputs found

    New genetic loci link adipose and insulin biology to body fat distribution.

    Get PDF
    Body fat distribution is a heritable trait and a well-established predictor of adverse metabolic outcomes, independent of overall adiposity. To increase our understanding of the genetic basis of body fat distribution and its molecular links to cardiometabolic traits, here we conduct genome-wide association meta-analyses of traits related to waist and hip circumferences in up to 224,459 individuals. We identify 49 loci (33 new) associated with waist-to-hip ratio adjusted for body mass index (BMI), and an additional 19 loci newly associated with related waist and hip circumference measures (P < 5 × 10(-8)). In total, 20 of the 49 waist-to-hip ratio adjusted for BMI loci show significant sexual dimorphism, 19 of which display a stronger effect in women. The identified loci were enriched for genes expressed in adipose tissue and for putative regulatory elements in adipocytes. Pathway analyses implicated adipogenesis, angiogenesis, transcriptional regulation and insulin resistance as processes affecting fat distribution, providing insight into potential pathophysiological mechanisms

    Use of the wearable cardioverter-defibrillator - the Swiss experience

    Get PDF
    INTRODUCTION Sudden cardiac death caused by malignant arrhythmia can be prevented by the use of defibrillators. Although the wearable cardioverter defibrillator (WCD) can prevent such an event, its role in clinical practice is ill defined. We investigated the use of the WCD in Switzerland with emphasis on prescription rate, therapy adherence and treatment rate. MATERIALS AND METHODS The Swiss WCD Registry is a retrospective observational registry including patients using a WCD. Patients were included from the first WCD use in Switzerland until February 2018. Baseline characteristics and data on WCD usage were examined for the total study population, and separately for each hospital. RESULTS From 1 December 2011 to 18 February 2018, a total of 456 patients (67.1% of all WCDs prescribed in Switzerland and 81.1% of all prescribed in the participating hospitals) were included in the registry. Up to 2017 there was a yearly increase in the number of prescribed WCDs to a maximum of 271 prescriptions per year. The mean age of patients was 57 years (&plusmn; 14), 81 (17.8%) were female and mean left ventricular ejection fraction (EF) was 32% (&plusmn; 13). The most common indications for WCD use were new-onset ischaemic cardiomyopathy (ICM) with EF &le;35% (206 patients, 45.2%), new-onset nonischaemic cardiomyopathy (NICM) with EF &le;35% (115 patients, 25.2%), unknown arrhythmic risk (83 patients, 18.2%), bridging to implantable cardioverter-defibrillator implantation or heart transplant (37 patients, 8.1%) and congenital/inherited heart disease (15 patients, 3.3%). Median wear duration was 58 days (interquartile range [IQR] 31&ndash;94) with a median average daily wear time of 22.6 hours (IQR 20&ndash;23.2). Seventeen appropriate therapies from the WCD were delivered in the whole population (treatment rate: 3.7%) to a total of 12 patients (2.6% of all patients). The most common underlying heart disease in patients with a treatment was ICM (13/17, 76.5%). There were no inappropriate treatments. CONCLUSION The use of WCDs has increased in Switzerland over the years for a variety of indications. There is high therapy adherence to the WCD, and a treatment rate comparable to previously published registry data. &nbsp

    High Incidence of Inappropriate Alarms in Patients with Wearable Cardioverter-Defibrillators: Findings from the Swiss WCD Registry

    Full text link
    BACKGROUND The wearable cardioverter defibrillator (WCD) uses surface electrodes to detect arrhythmia before initiating a treatment sequence. However, it is also prone to inappropriate detection due to artefacts. OBJECTIVE The aim of this study is to assess the alarm burden in patients and its impact on clinical outcomes. METHODS Patients from the nationwide Swiss WCD Registry were included. Clinical characteristics and data were obtained from the WCDs. Arrhythmia recordings ≥30 s in length were analysed and categorized as VT/VF, atrial fibrillation (AF), supraventricular tachycardia (SVT) or artefact. RESULTS A total of 10653 device alarms were documented in 324 of 456 patients (71.1%) over a mean WCD wear-time of 2.0 ± 1.6 months. Episode duration was 30 s or more in 2996 alarms (28.2%). One hundred and eleven (3.7%) were VT/VF episodes. The remaining recordings were inappropriate detections (2736 (91%) due to artefacts; 117 (3.7%) AF; 48 (1.6%) SVT). Two-hundred and seven patients (45%) had three or more alarms per month. Obesity was significantly associated with three or more alarms per month (p = 0.01, 27.7% vs. 15.9%). High alarm burden was not associated with a lower average daily wear time (20.8 h vs. 20.7 h, p = 0.785) or a decreased implantable cardioverter defibrillator implantation rate after stopping WCD use (48% vs. 47.3%, p = 0.156). CONCLUSIONS In patients using WCDs, alarms emitted by the device and impending inappropriate shocks were frequent and most commonly caused by artefacts. A high alarm burden was associated with obesity but did not lead to a decreased adherence

    High Incidence of Inappropriate Alarms in Patients with Wearable Cardioverter-Defibrillators: Findings from the Swiss WCD Registry.

    No full text
    BACKGROUND The wearable cardioverter defibrillator (WCD) uses surface electrodes to detect arrhythmia before initiating a treatment sequence. However, it is also prone to inappropriate detection due to artefacts. OBJECTIVE The aim of this study is to assess the alarm burden in patients and its impact on clinical outcomes. METHODS Patients from the nationwide Swiss WCD Registry were included. Clinical characteristics and data were obtained from the WCDs. Arrhythmia recordings ≥30 s in length were analysed and categorized as VT/VF, atrial fibrillation (AF), supraventricular tachycardia (SVT) or artefact. RESULTS A total of 10653 device alarms were documented in 324 of 456 patients (71.1%) over a mean WCD wear-time of 2.0 ± 1.6 months. Episode duration was 30 s or more in 2996 alarms (28.2%). One hundred and eleven (3.7%) were VT/VF episodes. The remaining recordings were inappropriate detections (2736 (91%) due to artefacts; 117 (3.7%) AF; 48 (1.6%) SVT). Two-hundred and seven patients (45%) had three or more alarms per month. Obesity was significantly associated with three or more alarms per month (p = 0.01, 27.7% vs. 15.9%). High alarm burden was not associated with a lower average daily wear time (20.8 h vs. 20.7 h, p = 0.785) or a decreased implantable cardioverter defibrillator implantation rate after stopping WCD use (48% vs. 47.3%, p = 0.156). CONCLUSIONS In patients using WCDs, alarms emitted by the device and impending inappropriate shocks were frequent and most commonly caused by artefacts. A high alarm burden was associated with obesity but did not lead to a decreased adherence

    Somatic mosaicism and common genetic variation contribute to the risk of very-early-onset inflammatory bowel disease

    No full text
    Very-early-onset inflammatory bowel disease (VEO-IBD) is a heterogeneous phenotype associated with a spectrum of rare Mendelian disorders. Here, we perform whole-exome-sequencing and genome-wide genotyping in 145 patients (median age-at-diagnosis of 3.5 years), in whom no Mendelian disorders were clinically suspected. In five patients we detect a primary immunodeficiency or enteropathy, with clinical consequences (XIAP, CYBA, SH2D1A, PCSK1). We also present a case study of a VEO-IBD patient with a mosaic de novo, pathogenic allele in CYBB. The mutation is present in ~70% of phagocytes and sufficient to result in defective bacterial handling but not life-threatening infections. Finally, we show that VEO-IBD patients have, on average, higher IBD polygenic risk scores than population controls (99 patients and 18,780 controls; P &lt; 4 × 10-10), and replicate this finding in an independent cohort of VEO-IBD cases and controls (117 patients and 2,603 controls; P &lt; 5 × 10-10). This discovery indicates that a polygenic component operates in VEO-IBD pathogenesis