206 research outputs found

    Curing and post-curing luminescence in an epoxy resin

    Full text link
    A spontaneous luminescence is reported when epoxy resin samples are heated in air. This phenomenon is very sensitive to the nature of the atmosphere. The same treatment in nitrogen leads to an extinction of the luminescence. The emission process is restored when samples are kept for a sufficient time in air. In order to better understand this phenomenon, we have investigated the luminescence of the elementary constituents of the epoxy (resin and hardener) when heated in air and nitrogen, as well as during resin curing in the same atmospheres. It appears that the emission process is linked with the presence of oxygen. Although the kinetics of the luminescence can differ depending on the nature of the sample (cured resin, resin during curing, liquid components), the emission spectra are the same during resin curing and upon heating of the cured resin and hardener. The emission spectrum of the base resin is different. It is concluded that the light results from a chemiluminescence process during oxidation.Comment: p. 1

    Effects of mesenchymal stromal cells versus serum on tendon healing in a controlled experimental trial in an equine model

    Get PDF
    Abstract Background Mesenchymal stromal cells (MSC) have shown promising results in the treatment of tendinopathy in equine medicine, making this therapeutic approach seem favorable for translation to human medicine. Having demonstrated that MSC engraft within the tendon lesions after local injection in an equine model, we hypothesized that they would improve tendon healing superior to serum injection alone. Methods Quadrilateral tendon lesions were induced in six horses by mechanical tissue disruption combined with collagenase application 3 weeks before treatment. Adipose-derived MSC suspended in serum or serum alone were then injected intralesionally. Clinical examinations, ultrasound and magnetic resonance imaging were performed over 24 weeks. Tendon biopsies for histological assessment were taken from the hindlimbs 3 weeks after treatment. Horses were sacrificed after 24 weeks and forelimb tendons were subjected to macroscopic and histological examination as well as analysis of musculoskeletal marker expression. Results Tendons injected with MSC showed a transient increase in inflammation and lesion size, as indicated by clinical and imaging parameters between week 3 and 6 (p < 0.05). Thereafter, symptoms decreased in both groups and, except that in MSC-treated tendons, mean lesion signal intensity as seen in T2w magnetic resonance imaging and cellularity as seen in the histology (p < 0.05) were lower, no major differences could be found at week 24. Conclusions These data suggest that MSC have influenced the inflammatory reaction in a way not described in tendinopathy studies before. However, at the endpoint of the current study, 24 weeks after treatment, no distinct improvement was observed in MSC-treated tendons compared to the serum-injected controls. Future studies are necessary to elucidate whether and under which conditions MSC are beneficial for tendon healing before translation into human medicine

    Euclid preparation. XXIV. Calibration of the halo mass function in Λ(ν)CDM cosmologies

    Get PDF
    Euclid’s photometric galaxy cluster survey has the potential to be a very competitive cosmological probe. The main cosmological probe with observations of clusters is their number count, within which the halo mass function (HMF) is a key theoretical quantity. We present a new calibration of the analytic HMF, at the level of accuracy and precision required for the uncertainty in this quantity to be subdominant with respect to other sources of uncertainty in recovering cosmological parameters from Euclid cluster counts. Our model is calibrated against a suite of N-body simulations using a Bayesian approach taking into account systematic errors arising from numerical effects in the simulation. First, we test the convergence of HMF predictions from different N-body codes, by using initial conditions generated with different orders of Lagrangian Perturbation theory, and adopting different simulation box sizes and mass resolution. Then, we quantify the effect of using different halo finder algorithms, and how the resulting differences propagate to the cosmological constraints. In order to trace the violation of universality in the HMF, we also analyse simulations based on initial conditions characterised by scale-free power spectra with different spectral indexes, assuming both Einstein–de Sitter and standard ΛCDM expansion histories. Based on these results, we construct a fitting function for the HMF that we demonstrate to be sub-percent accurate in reproducing results from 9 different variants of the ΛCDM model including massive neutrinos cosmologies. The calibration systematic uncertainty is largely sub-dominant with respect to the expected precision of future mass–observation relations; with the only notable exception of the effect due to the halo finder, that could lead to biased cosmological inference

    Distributed temperature sensing as a down-hole tool in hydrogeology

    Get PDF
    Distributed Temperature Sensing (DTS) technology enables down-hole temperature monitoring to study hydrogeological processes at unprecedentedly high frequency and spatial resolution. DTS has been widely applied in passive mode in site investigations of groundwater flow, in-well flow, and subsurface thermal property estimation. However, recent years have seen the further development of the use of DTS in an active mode (A-DTS) for which heat sources are deployed. A suite of recent studies using A-DTS down-hole in hydrogeological investigations illustrate the wide range of different approaches and creativity in designing methodologies. The purpose of this review is to outline and discuss the various applications and limitations of DTS in down-hole investigations for hydrogeological conditions and aquifer geological properties. To this end, we first review examples where passive DTS has been used to study hydrogeology via down-hole applications. Secondly, we discuss and categorize current A-DTS borehole methods into three types. These are thermal advection tests, hybrid cable flow logging, and heat pulse tests. We explore the various options with regards to cable installation, heating approach, duration, and spatial extent in order to improve their applicability in a range of settings. These determine the extent to which each method is sensitive to thermal properties, vertical in well flow, or natural gradient flow. Our review confirms that the application of DTS has significant advantages over discrete point temperature measurements, particularly in deep wells, and highlights the potential for further method developments in conjunction with other emerging fiber optic based sensors such as Distributed Acoustic Sensing. This article is protected by copyright. All rights reserved

    Perioperative outcome of laparoscopic left lateral liver resection is improved by using a bioabsorbable staple line reinforcement material in a porcine model

    Get PDF
    Hypothesis Laparoscopic liver surgery is significantly limited by the technical difficulty encountered during transection of substantial liver parenchyma, with intraoperative bleeding and bile leaks. This study tested whether the use of a bioabsorble staple line reinforcement material would improve outcome during stapled laparoscopic left lateral liver resection in a porcine model. Study design A total of 20 female pigs underwent stapled laparoscopic left lateral liver resection. In group A (n = 10), the stapling devices were buttressed with a bioabsorbable staple line reinforcement material. In group B (n = 10), standard laparoscopic staplers were used. Operative data and perioperative complications were recorded. Necropsy studies and histopathological analysis were performed at 6 weeks. Data were compared between groups with the Student's t-test or the chi-square test. Results Operating time was similar in the two groups (64 +/- 11 min in group A versus 68 +/- 9 min in group B, p = ns). Intraoperative blood loss was significantly higher in group B (185 +/- 9 mL versus 25 +/- 5 mL, p <0.05). There was no mortality. There was no morbidity in the 6-week follow-up period; however, two animals in group B had subphrenic bilomas (20%) at necropsy. At necropsy, methylene blue injection via the main bile duct revealed leakage from the biliary tree in four animals in group B and none in group A (p <0.05). Histopathological examination of the resection site revealed minor abnormalities in group A while animals in group B demonstrated marked fibrotic changes and damaged vascular and biliary endothelium. Conclusion Use of a bioabsorbable staple line reinforcement material reduces intraoperative bleeding and perioperative bile leaks during stapled laparoscopic left lateral liver resection in a porcine model

    Estimating EQ-5D utilities based on the Short-Form Long Term Conditions Questionnaire (LTCQ-8)

    Get PDF
    Purpose: The aim of this work was to develop a mapping algorithm for estimating EuroQoL 5 Dimension (EQ-5D) utilities from responses to the Long-Term Conditions Questionnaire (LTCQ), thus increasing LTCQ’s potential as a comprehensive outcome measure for evaluating integrated care initiatives. Methods: We combined data from three studies to give a total sample of 1334 responses. In each of the three datasets, we randomly selected 75% of the sample and combined the selected random samples to generate the estimation dataset, which consisted of 1001 patients. The unselected 25% observations from each dataset were combined to generate an internal validation dataset of 333 patients. We used direct mapping models by regressing responses to the LTCQ-8 directly onto EQ-5D-5L and EQ-5D-3L utilities as well as response (or indirect) mapping to predict the response level that patients selected for each of the five EQ-5D-5L domains. Several models were proposed and compared on mean squared error and mean absolute error. Results: A two-part model with OLS was the best performing based on the mean squared error (0.038) and mean absolute error (0.147) when estimating the EQ-5D-5L utilities. A multinomial response mapping model using LTCQ-8 responses was used to predict EQ-5D-5L responses levels. Conclusions: This study provides a mapping algorithm for estimating EQ-5D utilities from LTCQ responses. The results from this study can help broaden the applicability of the LTCQ by producing utility values for use in economic analyses

    Illusory Stimuli Can Be Used to Identify Retinal Blind Spots

    Get PDF
    Background. Identification of visual field loss in people with retinal disease is not straightforward as people with eye disease are frequently unaware of substantial deficits in their visual field, as a consequence of perceptual completion ("filling-in'') of affected areas. Methodology. We attempted to induce a compelling visual illusion known as the induced twinkle after-effect (TwAE) in eight patients with retinal scotomas. Half of these patients experience filling-in of their scotomas such that they are unaware of the presence of their scotoma, and conventional campimetric techniques can not be used to identify their vision loss. The region of the TwAE was compared to microperimetry maps of the retinal lesion. Principal Findings. Six of our eight participants experienced the TwAE. This effect occurred in three of the four people who filled-in their scotoma. The boundary of the TwAE showed good agreement with the boundary of lesion, as determined by microperimetry. Conclusion. For the first time, we have determined vision loss by asking patients to report the presence of an illusory percept in blind areas, rather than the absence of a real stimulus. This illusory technique is quick, accurate and not subject to the effects of filling-in
    corecore