130 research outputs found

    Health services changes: is a run-in period necessary before evaluation in randomised clinical trials?

    Get PDF
    Background Most randomised clinical trials (RCTs) testing a new health service do not allow a run-in period of consolidation before evaluating the new approach. Consequently, health professionals involved may feel insufficiently familiar or confident, or that new processes or systems that are integral to the service are insufficiently embedded in routine care prior to definitive evaluation in a RCT. This study aimed to determine the optimal run-in period for a new physiotherapy-led telephone assessment and treatment service known as PhysioDirect and whether a run-in was needed prior to evaluating outcomes in an RCT. Methods The PhysioDirect trial assessed whether PhysioDirect was as effective as usual care. Prior to the main trial, a run-in of up to 12 weeks was permitted to facilitate physiotherapists to become confident in delivering the new service. Outcomes collected from the run-in and main trial were length of telephone calls within the PhysioDirect service and patients’ physical function (SF-36v2 questionnaire) and Measure Yourself Medical Outcome Profile v2 collected at baseline and six months. Joinpoint regression determined how long it had taken call times to stabilise. Analysis of covariance determined whether patients’ physical function at six months changed from the run-in to the main trial. Results Mean PhysioDirect call times (minutes) were higher in the run-in (31 (SD: 12.6)) than in the main trial (25 (SD: 11.6)). Each physiotherapist needed to answer 42 (95% CI: 20,56) calls for their mean call time to stabilise at 25 minutes per call; this took a minimum of seven weeks. For patients’ physical function, PhysioDirect was equally clinically effective as usual care during both the run-in (0.17 (95% CI: -0.91,1.24)) and main trial (-0.01 (95% CI: -0.80,0.79)). Conclusions A run-in was not needed in a large trial testing PhysioDirect services in terms of patient outcomes. A learning curve was evident in the process measure of telephone call length. This decreased during the run-in and stabilised prior to commencement of the main trial. Future trials should build in a run-in if it is anticipated that learning would have an effect on patient outcome

    Wartenberg’s migrant sensory neuritis: a prospective follow-up study

    Get PDF
    Migrant sensory neuropathy (Wartenberg’s migrant sensory neuritis) is characterized by sudden numbness in the distribution of one or multiple cutaneous nerves. To study disease course and outcome, we prospectively followed 12 patients who presented to our tertiary referral neuromuscular outpatient clinic between January 2003 and January 2004. Medical history, neurological, laboratory and electrophysiological examinations were obtained from all patients. All patients were reviewed a second time in 2007, and five had a follow-up electrophysiological examination. At the first visit, 50% described an episode of stretching preceding the sensory complaints. All but three described pain in the affected area before or concomitant with sensory loss. At clinical examination a median of six skin areas were affected, and in 75% this could be confirmed by nerve conduction studies in at least one nerve. Forty-two percent had involvement of the trigeminal nerve. After a mean disease duration of 7.5 years, three patients reported a complete disappearance of sensory complaints and five that the pain had disappeared, but numbness remained. Three patients still had both painful and numb sensory deficits. One patient developed a distal symmetric sensory polyneuropathy. In conclusion, Wartenberg’s sensory neuritis is a distinct, exclusively sensory, neuropathy, marked by pain preceding numbness in affected nerves. An episode of stretching preceding pain is not necessary for the diagnosis. Wartenberg’s sensory neuritis often retains its spotty, exclusively sensory characteristics after long term follow-up

    Circulating adrenomedullin estimates survival and reversibility of organ failure in sepsis: the prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock-1 (AdrenOSS-1) study

    Get PDF
    Background: Adrenomedullin (ADM) regulates vascular tone and endothelial permeability during sepsis. Levels of circulating biologically active ADM (bio-ADM) show an inverse relationship with blood pressure and a direct relationship with vasopressor requirement. In the present prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock 1 (, AdrenOSS-1) study, we assessed relationships between circulating bio-ADM during the initial intensive care unit (ICU) stay and short-term outcome in order to eventually design a biomarker-guided randomized controlled trial. Methods: AdrenOSS-1 was a prospective observational multinational study. The primary outcome was 28-day mortality. Secondary outcomes included organ failure as defined by Sequential Organ Failure Assessment (SOFA) score, organ support with focus on vasopressor/inotropic use, and need for renal replacement therapy. AdrenOSS-1 included 583 patients admitted to the ICU with sepsis or septic shock. Results: Circulating bio-ADM levels were measured upon admission and at day 2. Median bio-ADM concentration upon admission was 80.5 pg/ml [IQR 41.5-148.1 pg/ml]. Initial SOFA score was 7 [IQR 5-10], and 28-day mortality was 22%. We found marked associations between bio-ADM upon admission and 28-day mortality (unadjusted standardized HR 2.3 [CI 1.9-2.9]; adjusted HR 1.6 [CI 1.1-2.5]) and between bio-ADM levels and SOFA score (p < 0.0001). Need of vasopressor/inotrope, renal replacement therapy, and positive fluid balance were more prevalent in patients with a bio-ADM > 70 pg/ml upon admission than in those with bio-ADM ≤ 70 pg/ml. In patients with bio-ADM > 70 pg/ml upon admission, decrease in bio-ADM below 70 pg/ml at day 2 was associated with recovery of organ function at day 7 and better 28-day outcome (9.5% mortality). By contrast, persistently elevated bio-ADM at day 2 was associated with prolonged organ dysfunction and high 28-day mortality (38.1% mortality, HR 4.9, 95% CI 2.5-9.8). Conclusions: AdrenOSS-1 shows that early levels and rapid changes in bio-ADM estimate short-term outcome in sepsis and septic shock. These data are the backbone of the design of the biomarker-guided AdrenOSS-2 trial. Trial registration: ClinicalTrials.gov, NCT02393781. Registered on March 19, 2015

    Circulating adrenomedullin estimates survival and reversibility of organ failure in sepsis: the prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock-1 (AdrenOSS-1) study

    Get PDF
    BACKGROUND: Adrenomedullin (ADM) regulates vascular tone and endothelial permeability during sepsis. Levels of circulating biologically active ADM (bio-ADM) show an inverse relationship with blood pressure and a direct relationship with vasopressor requirement. In the present prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock 1 (, AdrenOSS-1) study, we assessed relationships between circulating bio-ADM during the initial intensive care unit (ICU) stay and short-term outcome in order to eventually design a biomarker-guided randomized controlled trial. METHODS: AdrenOSS-1 was a prospective observational multinational study. The primary outcome was 28-day mortality. Secondary outcomes included organ failure as defined by Sequential Organ Failure Assessment (SOFA) score, organ support with focus on vasopressor/inotropic use, and need for renal replacement therapy. AdrenOSS-1 included 583 patients admitted to the ICU with sepsis or septic shock. RESULTS: Circulating bio-ADM levels were measured upon admission and at day 2. Median bio-ADM concentration upon admission was 80.5 pg/ml [IQR 41.5-148.1 pg/ml]. Initial SOFA score was 7 [IQR 5-10], and 28-day mortality was 22%. We found marked associations between bio-ADM upon admission and 28-day mortality (unadjusted standardized HR 2.3 [CI 1.9-2.9]; adjusted HR 1.6 [CI 1.1-2.5]) and between bio-ADM levels and SOFA score (p < 0.0001). Need of vasopressor/inotrope, renal replacement therapy, and positive fluid balance were more prevalent in patients with a bio-ADM > 70 pg/ml upon admission than in those with bio-ADM ≤ 70 pg/ml. In patients with bio-ADM > 70 pg/ml upon admission, decrease in bio-ADM below 70 pg/ml at day 2 was associated with recovery of organ function at day 7 and better 28-day outcome (9.5% mortality). By contrast, persistently elevated bio-ADM at day 2 was associated with prolonged organ dysfunction and high 28-day mortality (38.1% mortality, HR 4.9, 95% CI 2.5-9.8). CONCLUSIONS: AdrenOSS-1 shows that early levels and rapid changes in bio-ADM estimate short-term outcome in sepsis and septic shock. These data are the backbone of the design of the biomarker-guided AdrenOSS-2 trial. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02393781 . Registered on March 19, 2015

    Severity Assessment of Lower Respiratory Tract Infection in Malawi: Derivation of a Novel Index (SWAT-Bp) Which Outperforms CRB-65

    Get PDF
    OBJECTIVE: To assess the validity of CRB-65 (Confusion, Respiratory rate >30 breaths/min, BP<90/60 mmHg, age >65 years) as a pneumonia severity index in a Malawian hospital population, and determine whether an alternative score has greater accuracy in this setting. DESIGN: Forty three variables were prospectively recorded during the first 48 hours of admission in all patients admitted to Queen Elizabeth Central Hospital, Malawi, for management of lower respiratory tract infection over a two month period (N = 240). Calculation of sensitivity and specificity for CRB-65 in predicting mortality was followed by multivariate modeling to create a score with superior performance in this population. RESULTS: Median age 37, HIV prevalence 79.9%, overall mortality 18.3%. CRB-65 predicted mortality poorly, indicated by the area under the ROC curve of 0.649. Independent predictors of death were: Male sex, “S” (AOR 2.6); Wasting, “W” (AOR 6.6); non-ambulatory, “A” (AOR 2.5); Temp >38°C or <35°C, “T” (AOR 3.2); BP<100/60, “Bp” (AOR 3.7). Combining these factors to form a severity index (SWAT-Bp) predicted mortality with high sensitivity and specificity (AUC: 0.867). Mortality for scores 0–5 was 0%, 3.3%, 7.4%, 29.2%, 61.5% and 87.5% respectively. A score ≥3 was 84% sensitive and 77% specific for mortality prediction, with a negative predictive value of 95.8%. CONCLUSION: CRB-65 performs poorly in this population. The SWAT-Bp score can accurately stratify patients; ≤2 indicates non-severe infection (mortality 4.4%) and ≥3 severe illness (mortality 45%)

    A large retrospective assessment of voriconazole exposure in patients treated with extracorporeal membrane oxygenation

    Get PDF
    Background: Voriconazole is one of the first-line therapies for invasive pulmonary aspergillosis. Drug concentrations might be significantly influenced by the use of extracorporeal membrane oxygenation (ECMO). We aimed to assess the effect of ECMO on voriconazole exposure in a large patient population. Methods: Critically ill patients from eight centers in four countries treated with voriconazole during ECMO support were included in this retrospective study. Voriconazole concentrations were collected in a period on ECMO and before/after ECMO treatment. Multivariate analyses were performed to evaluate the effect of ECMO on voriconazole exposure and to assess the impact of possible saturation of the circuit’s binding sites over time. Results: Sixty-nine patients and 337 samples (190 during and 147 before/after ECMO) were analyzed. Subtherapeutic concentrations (<2 mg/L) were observed in 56% of the samples during ECMO and 39% without ECMO (p = 0.80). The median trough concentration, for a similar daily dose, was 2.4 (1.2–4.7) mg/L under ECMO and 2.5 (1.4–3.9) mg/L without ECMO (p = 0.58). Extensive inter-and intrasubject variability were observed. Neither ECMO nor squared day of ECMO (saturation) were retained as significant covariates on voriconazole exposure. Conclusions: No significant ECMO-effect was observed on voriconazole exposure. A large proportion of patients had voriconazole subtherapeutic concentrations

    Erratum to: 36th International Symposium on Intensive Care and Emergency Medicine

    Get PDF
    [This corrects the article DOI: 10.1186/s13054-016-1208-6.]

    Fluid challenges in intensive care: the FENICE study A global inception cohort study

    Get PDF
    Fluid challenges (FCs) are one of the most commonly used therapies in critically ill patients and represent the cornerstone of hemodynamic management in intensive care units. There are clear benefits and harms from fluid therapy. Limited data on the indication, type, amount and rate of an FC in critically ill patients exist in the literature. The primary aim was to evaluate how physicians conduct FCs in terms of type, volume, and rate of given fluid; the secondary aim was to evaluate variables used to trigger an FC and to compare the proportion of patients receiving further fluid administration based on the response to the FC.This was an observational study conducted in ICUs around the world. Each participating unit entered a maximum of 20 patients with one FC.2213 patients were enrolled and analyzed in the study. The median [interquartile range] amount of fluid given during an FC was 500 ml (500-1000). The median time was 24 min (40-60 min), and the median rate of FC was 1000 [500-1333] ml/h. The main indication for FC was hypotension in 1211 (59 %, CI 57-61 %). In 43 % (CI 41-45 %) of the cases no hemodynamic variable was used. Static markers of preload were used in 785 of 2213 cases (36 %, CI 34-37 %). Dynamic indices of preload responsiveness were used in 483 of 2213 cases (22 %, CI 20-24 %). No safety variable for the FC was used in 72 % (CI 70-74 %) of the cases. There was no statistically significant difference in the proportion of patients who received further fluids after the FC between those with a positive, with an uncertain or with a negatively judged response.The current practice and evaluation of FC in critically ill patients are highly variable. Prediction of fluid responsiveness is not used routinely, safety limits are rarely used, and information from previous failed FCs is not always taken into account
    corecore