25 research outputs found

    Surface plasmons for enhanced metal-semiconductor-metal photodetectors

    Get PDF
    Surface Plasmon Polaritons (SPPs) are quantized charge density oscillations that occur when a photon couples to the free electron gas of the metal at the interface between a metal and a dielectric. The extraordinary properties of SPP allow for sub-diffraction limit waveguiding and localized field enhancement. The emerging field of surface plasmonics has applied SPP coupling to a number of new and interesting applications, such as: Surface Enhanced Raman Spectroscopy (SERS), super lenses, nano-scale optical circuits, optical filters and SPP enhanced photodetectors. In the past decade, there have been several experimental and theoretical research and development activities which reported on the extraordinary optical transmission through subwavelength metallic apertures as well as through periodic metal grating structures. The use of SPP for light absorption enhancement using sub-wavelength metal gratings promises an increased enhancement in light collection efficiency of photovoltaic devices. A subwavelength plasmonic nanostructure grating interacts strongly with the incident light and potentially traps it inside the subsurface region of semiconductor substrates. Among all photodetectors, the Metal-Semiconductor-Metal photodetector (MSM-PD) is the simplest structure. Moreover, due to the lateral geometry of the MSM-PDs, the capacitance of an MSM-PD is much lower than capacitances of p-i-n PDs and Avalanche PDs, making its response time in the range of a few tens of picoseconds for nano-scale spacing between the electrode fingers. These features of simple fabrication and high speed make MSM-PDs attractive and essential devices for high-speed optical interconnects, highsensitivity optical samplers and ultra-wide bandwidth optoelectronic integrated circuits (OEIC) receivers for fibre optic communication systems. However, while MSM-PDs offer faster response than their p-i-n PD and avalanche PD counterparts, their most significant drawbacks are the high reflectivity of the metal fingers and the very-low light transmission through the spacing between the fingers, leading to very low photodetector sensitivity. This thesis proposes, designs and demonstrates the concept of a novel plasmonicbased MSM-PD employing metal nano-gratings and sub-wavelength slits. Various metal nano-gratings are designed on top of the gold fingers of an MSM-PD based on gallium arsenide (GaAs) for an operating wavelength of 830 nm to create SPP-enhanced MSM-PDs. Both the geometry and light absorption near the designed wavelength are theoretically and experimentally investigated. Finite Difference Time Domain (FDTD) simulation is used to simulate and design plasmonic MSM-PDs devices for maximal field enhancement. The simulation results show more than 10 times enhancement for the plasmonic nano-grating MSM-PD compared with the device without the metal nano-gratings, for 100 nm slit difference, due to the improved optical signal propagation through the nano-gratings. A dual beam FIB/ SEM is employed for the fabrication of metal nano-gratings and the sub-wavelength slit of the MSM-PD. Experimentally, we demonstrate the principle of plasmonics-based MSM-PDs and attain a measured photodetector responsivity that is 4 times better than that of conventional single-slit MSM-PDs. We observe reduction in the responsivity as the bias voltage increases and the input light polarization varies. Our experimental results demonstrate the feasibility of developing high-responsivity, low bias-voltage high-speed MSM-PDs. A novel multi-finger plasmonics-based GaAs MSM-PD structure is optimized geometrically using the 2-D FDTD method and developed, leading to more than 7 times enhancement in photocurrent in comparison with the conventional MSM-PD of similar dimensions at a bias voltage as low as 0.3V. This enhancement is attributed to the coupling of SPPs with the incident light through the nano-structured metal fingers. Moreover, the plasmonic-based MSM-PD shows high sensitivity to the incident light polarization states. Combining the polarization sensitivity and the wavelength selective guiding nature of the nano-gratings, the plasmonic MSM-PD can be used to design high-sensitivity polarization diversity receivers, integrating polarization splitters and polarization CMOS imaging sensors. We also propose and demonstrate a plasmonic-based GaAs balanced metalsemiconductor- metal photodetector (B-MSM-PD) structure and we measure a common mode rejection ratio (CMRR) value less than 25 dB at 830nm wavelength. This efficient CMRR value makes our B-MSM-PD structure suitable for ultra-high-speed optical telecommunication systems. In addition, this work paves the way for the monolithic integration of B-MSM-PDs into large scale semiconductor circuits. This thesis demonstrates several new opportunities for resonant plasmonic nanostructures able to enhance the responsivity of the MSM-PD. The presented concepts and insights hold great promise for new applications in integrated optics, photovoltaics, solidstate lighting and imaging below the diffraction limit. In Chapter 10 we conclude this thesis by summarizing and discussing some possible applications and future research directions based on SPP field concentration

    Nano-Patterned High-Responsivity GaAs Metal-Semiconductor-Metal Photodetector

    Get PDF
    In this paper, we use the finite difference time-domain (FDTD) method to optimize the light absorption of an ultrafast nano-grating plasmonic GaAs metal-semiconductor-metal photodetector (MSM-PD) employing double metal nano-gratings. The geometry of the MSM-PD is theoretically investigated, leading to improved light absorption near the design wavelength of GaAs due to plasmon-assisted electric and magnetic field concentration through a subwavelength aperture. Simulation results show up to 8- and 21-times light absorption enhancement for the single and double nano-grating structure, respectively, in comparison to conventional MSM-PDs. Experimentally, more than 4 times enhancement in photocurrent is demonstrated for a single top nano-grating MSM-PD in comparison with conventional MSM-PDs

    Design of high-sensitivity plasmonics-assisted GaAs Metal-Semiconductor-Metal photodetectors

    Get PDF
    In this paper, we use the finite difference timedomain (FDTD) method to optimize the light absorption of an ultrafast plasmonic GaAs metal-semiconductor-metal photodetector (MSM-PD) employing metal nano-gratings. The MSM-PD is optimized geometrically, leading to improved light absorption near the designed wavelength of GaAs through plasmon-assisted electric and magnetic field concentration through a subwavelength aperture. Simulation results show up to 10-times light absorption enhancement at 867 nm due to surface plasmon polaritons (SPPs) propagation through the metal nano-grating, in comparison to conventional MSM-PD

    Metal-semiconductor-metal photodetector with enhanced TE-polarization transmission

    Get PDF
    In this paper, we use the finite difference time-domain (FDTD) method to optimize the TE-polarized light transmission of a metal-semiconductor-metal photodetector (MSMPD) employing a dielectric waveguide on top of metal nano-gratings. Simulation results demonstrate that the funneling transmission of the TE-polarized light through the nanoslit of the structure is highly dependent on the structure geometries such as the waveguide and nano-grating heights. We also demonstrate that adding a dielectric waveguide layer on top of the nano-metal grating supports both the TM- and TE polarizations, and enhances the light transmission for TE-polarization approximately 3-times

    Groove shape-dependent absorption enhancement of 850 nm MSM photodetectors with nano-gratings

    Get PDF
    Finite difference time-domain (FDTD) analysis is used to investigate the light absorption enhancement factor dependence on the groove shape of the nano-gratings etched into the surfaces of metal-semiconductor-metal photodetector (MSM-PD) structures. By patterning the MSM-PDs with optimized nano-gratings a significant improvement in light absorption near the design wavelength is achieved through plasmon-assisted electric field concentration effects. Simulation results show about 50 times light absorption enhancement for 850 nm light due to improved optical signal propagation through the nano-gratings

    Effects of hospital facilities on patient outcomes after cancer surgery: an international, prospective, observational study

    Get PDF
    Background Early death after cancer surgery is higher in low-income and middle-income countries (LMICs) compared with in high-income countries, yet the impact of facility characteristics on early postoperative outcomes is unknown. The aim of this study was to examine the association between hospital infrastructure, resource availability, and processes on early outcomes after cancer surgery worldwide.Methods A multimethods analysis was performed as part of the GlobalSurg 3 study-a multicentre, international, prospective cohort study of patients who had surgery for breast, colorectal, or gastric cancer. The primary outcomes were 30-day mortality and 30-day major complication rates. Potentially beneficial hospital facilities were identified by variable selection to select those associated with 30-day mortality. Adjusted outcomes were determined using generalised estimating equations to account for patient characteristics and country-income group, with population stratification by hospital.Findings Between April 1, 2018, and April 23, 2019, facility-level data were collected for 9685 patients across 238 hospitals in 66 countries (91 hospitals in 20 high-income countries; 57 hospitals in 19 upper-middle-income countries; and 90 hospitals in 27 low-income to lower-middle-income countries). The availability of five hospital facilities was inversely associated with mortality: ultrasound, CT scanner, critical care unit, opioid analgesia, and oncologist. After adjustment for case-mix and country income group, hospitals with three or fewer of these facilities (62 hospitals, 1294 patients) had higher mortality compared with those with four or five (adjusted odds ratio [OR] 3.85 [95% CI 2.58-5.75]; p<0.0001), with excess mortality predominantly explained by a limited capacity to rescue following the development of major complications (63.0% vs 82.7%; OR 0.35 [0.23-0.53]; p<0.0001). Across LMICs, improvements in hospital facilities would prevent one to three deaths for every 100 patients undergoing surgery for cancer.Interpretation Hospitals with higher levels of infrastructure and resources have better outcomes after cancer surgery, independent of country income. Without urgent strengthening of hospital infrastructure and resources, the reductions in cancer-associated mortality associated with improved access will not be realised

    Elective cancer surgery in COVID-19-free surgical pathways during the SARS-CoV-2 pandemic: An international, multicenter, comparative cohort study

    Get PDF
    PURPOSE As cancer surgery restarts after the first COVID-19 wave, health care providers urgently require data to determine where elective surgery is best performed. This study aimed to determine whether COVID-19–free surgical pathways were associated with lower postoperative pulmonary complication rates compared with hospitals with no defined pathway. PATIENTS AND METHODS This international, multicenter cohort study included patients who underwent elective surgery for 10 solid cancer types without preoperative suspicion of SARS-CoV-2. Participating hospitals included patients from local emergence of SARS-CoV-2 until April 19, 2020. At the time of surgery, hospitals were defined as having a COVID-19–free surgical pathway (complete segregation of the operating theater, critical care, and inpatient ward areas) or no defined pathway (incomplete or no segregation, areas shared with patients with COVID-19). The primary outcome was 30-day postoperative pulmonary complications (pneumonia, acute respiratory distress syndrome, unexpected ventilation). RESULTS Of 9,171 patients from 447 hospitals in 55 countries, 2,481 were operated on in COVID-19–free surgical pathways. Patients who underwent surgery within COVID-19–free surgical pathways were younger with fewer comorbidities than those in hospitals with no defined pathway but with similar proportions of major surgery. After adjustment, pulmonary complication rates were lower with COVID-19–free surgical pathways (2.2% v 4.9%; adjusted odds ratio [aOR], 0.62; 95% CI, 0.44 to 0.86). This was consistent in sensitivity analyses for low-risk patients (American Society of Anesthesiologists grade 1/2), propensity score–matched models, and patients with negative SARS-CoV-2 preoperative tests. The postoperative SARS-CoV-2 infection rate was also lower in COVID-19–free surgical pathways (2.1% v 3.6%; aOR, 0.53; 95% CI, 0.36 to 0.76). CONCLUSION Within available resources, dedicated COVID-19–free surgical pathways should be established to provide safe elective cancer surgery during current and before future SARS-CoV-2 outbreaks

    Elective Cancer Surgery in COVID-19-Free Surgical Pathways During the SARS-CoV-2 Pandemic: An International, Multicenter, Comparative Cohort Study.

    Get PDF
    PURPOSE: As cancer surgery restarts after the first COVID-19 wave, health care providers urgently require data to determine where elective surgery is best performed. This study aimed to determine whether COVID-19-free surgical pathways were associated with lower postoperative pulmonary complication rates compared with hospitals with no defined pathway. PATIENTS AND METHODS: This international, multicenter cohort study included patients who underwent elective surgery for 10 solid cancer types without preoperative suspicion of SARS-CoV-2. Participating hospitals included patients from local emergence of SARS-CoV-2 until April 19, 2020. At the time of surgery, hospitals were defined as having a COVID-19-free surgical pathway (complete segregation of the operating theater, critical care, and inpatient ward areas) or no defined pathway (incomplete or no segregation, areas shared with patients with COVID-19). The primary outcome was 30-day postoperative pulmonary complications (pneumonia, acute respiratory distress syndrome, unexpected ventilation). RESULTS: Of 9,171 patients from 447 hospitals in 55 countries, 2,481 were operated on in COVID-19-free surgical pathways. Patients who underwent surgery within COVID-19-free surgical pathways were younger with fewer comorbidities than those in hospitals with no defined pathway but with similar proportions of major surgery. After adjustment, pulmonary complication rates were lower with COVID-19-free surgical pathways (2.2% v 4.9%; adjusted odds ratio [aOR], 0.62; 95% CI, 0.44 to 0.86). This was consistent in sensitivity analyses for low-risk patients (American Society of Anesthesiologists grade 1/2), propensity score-matched models, and patients with negative SARS-CoV-2 preoperative tests. The postoperative SARS-CoV-2 infection rate was also lower in COVID-19-free surgical pathways (2.1% v 3.6%; aOR, 0.53; 95% CI, 0.36 to 0.76). CONCLUSION: Within available resources, dedicated COVID-19-free surgical pathways should be established to provide safe elective cancer surgery during current and before future SARS-CoV-2 outbreaks

    Dielectric waveguide optimization for the enhancement of TE-polarisation transmission of plasmonics-based MSM-PD

    No full text
    In this paper, we use the finite difference time-domain (FDTD) method to optimize the TE-polarized light transmission of a metal-semiconductor-metal photodetector (MSM-PD) employing a dielectric waveguide on top of metal nano-gratings. Simulation results demonstrate that the funneling transmission of the TE-polarized light through the nanoslit of the MSM-PD structure is highly dependent on the structure geometries, such as the waveguide and nano-grating heights. We also demonstrate that adding a dielectric waveguide layer on top of the nano-metal gratings supports both the TM- and TE polarizations, and enhances the light transmission for TE-polarization around 3-times in comparison with conventional plasmonics MSMPD structures
    corecore