61 research outputs found

    The Shaqadud Archaeological Project (Sudan): exploring prehistoric cultural adaptations in the Sahelian hinterlands

    Get PDF
    The authors present preliminary results from a new research project based in Jebel Shaqadud, Sudan. Their findings highlight the potential for this region's archaeological record to expand our understanding of the adaptation strategies used by human groups in arid north-east African environments away from rivers and lakes during the Holocene. Furthermore, they present exceptionally early radiocarbon dates that push postglacial human occupation in the eastern Sahel back to the twelfth millennium BP

    Spatially Explicit Analysis of Metal Transfer to Biota: Influence of Soil Contamination and Landscape

    Get PDF
    Concepts and developments for a new field in ecotoxicology, referred to as “landscape ecotoxicology,” were proposed in the 1990s; however, to date, few studies have been developed in this emergent field. In fact, there is a strong interest in developing this area, both for renewing the concepts and tools used in ecotoxicology as well as for responding to practical issues, such as risk assessment. The aim of this study was to investigate the spatial heterogeneity of metal bioaccumulation in animals in order to identify the role of spatially explicit factors, such as landscape as well as total and extractable metal concentrations in soils. Over a smelter-impacted area, we studied the accumulation of trace metals (TMs: Cd, Pb and Zn) in invertebrates (the grove snail Cepaea sp and the glass snail Oxychilus draparnaudi) and vertebrates (the bank vole Myodes glareolus and the greater white-toothed shrew Crocidura russula). Total and CaCl2-extractable concentrations of TMs were measured in soils from woody patches where the animals were captured. TM concentrations in animals exhibited a high spatial heterogeneity. They increased with soil pollution and were better explained by total rather than CaCl2-extractable TM concentrations, except in Cepaea sp. TM levels in animals and their variations along the pollution gradient were modulated by the landscape, and this influence was species and metal specific. Median soil metal concentrations (predicted by universal kriging) were calculated in buffers of increasing size and were related to bioaccumulation. The spatial scale at which TM concentrations in animals and soils showed the strongest correlations varied between metals, species and landscapes. The potential underlying mechanisms of landscape influence (community functioning, behaviour, etc.) are discussed. Present results highlight the need for the further development of landscape ecotoxicology and multi-scale approaches, which would enhance our understanding of pollutant transfer and effects in ecosystems

    Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Get PDF
    The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 μ\mum thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to 310153 \cdot 10^{15} neq/cm2^2. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations

    Description and performance of track and primary-vertex reconstruction with the CMS tracker

    Get PDF
    A description is provided of the software algorithms developed for the CMS tracker both for reconstructing charged-particle trajectories in proton-proton interactions and for using the resulting tracks to estimate the positions of the LHC luminous region and individual primary-interaction vertices. Despite the very hostile environment at the LHC, the performance obtained with these algorithms is found to be excellent. For tbar t events under typical 2011 pileup conditions, the average track-reconstruction efficiency for promptly-produced charged particles with transverse momenta of pT > 0.9GeV is 94% for pseudorapidities of |η| < 0.9 and 85% for 0.9 < |η| < 2.5. The inefficiency is caused mainly by hadrons that undergo nuclear interactions in the tracker material. For isolated muons, the corresponding efficiencies are essentially 100%. For isolated muons of pT = 100GeV emitted at |η| < 1.4, the resolutions are approximately 2.8% in pT, and respectively, 10μm and 30μm in the transverse and longitudinal impact parameters. The position resolution achieved for reconstructed primary vertices that correspond to interesting pp collisions is 10–12μm in each of the three spatial dimensions. The tracking and vertexing software is fast and flexible, and easily adaptable to other functions, such as fast tracking for the trigger, or dedicated tracking for electrons that takes into account bremsstrahlung

    Alignment of the CMS tracker with LHC and cosmic ray data

    Get PDF
    © CERN 2014 for the benefit of the CMS collaboration, published under the terms of the Creative Commons Attribution 3.0 License by IOP Publishing Ltd and Sissa Medialab srl. Any further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation and DOI.The central component of the CMS detector is the largest silicon tracker ever built. The precise alignment of this complex device is a formidable challenge, and only achievable with a significant extension of the technologies routinely used for tracking detectors in the past. This article describes the full-scale alignment procedure as it is used during LHC operations. Among the specific features of the method are the simultaneous determination of up to 200 000 alignment parameters with tracks, the measurement of individual sensor curvature parameters, the control of systematic misalignment effects, and the implementation of the whole procedure in a multi-processor environment for high execution speed. Overall, the achieved statistical accuracy on the module alignment is found to be significantly better than 10μm

    Cooperation with dentist technician. How to take the dental impression properly

    No full text
    Współpraca lekarza stomatologa z technikiem dentystycznym stanowi jeden z prominentnych warunków prowadzenia skutecznego leczenia protetycznego. W gestii każdego z nich znajdują się określone zadania, które muszą zostać precyzyjnie zrealizowane, przy wzajemnej konsultacji oraz zrozumieniu potrzeb pacjenta. Jest to szczególnie ważne w kontekście prawnego zakazu kontaktu technika dentystycznego z osobą leczoną, który sprawia, że wykonany wycisk jest kluczowy w procesie przekazywania informacji pomiędzy gabinetem stomatologicznym a pracownią techniczną.Cooperation of dentist with dental technician is one of the prominent conditions for effective prosthetic treatment. There are certain tasks that must be precisely executed, by mutual consultation and understanding of the needs of the patient. This is particularly important in the framework of the law, which forbids dental technician contact with a person treated. It makes that dental impression is crucial in the process of transferring information between dental office and laboratory support

    Use of Cyclodextrin-Cholesterol Complex as a Primary Standard in Cholesterol Analysis

    Full text link
    Cholesterol is an analyte commonly measured in various biological fluids. Enzymic procedures have virtually replaced the chemical methods for cholesterol determinations. Standardization of cholesterol assays often involve the use of solutions of this steroid containing organic solvents and/or detergents, or alternatively, the use of secondary standards. The present report shows the preparation of a primary cholesterol standard by its complexation with a chemically modified cyclodextrin. hydroxylpropyl [beta]-cyclodextrin. The use of cyclodextrin for cholesterol solubilization is not deleterious to the enzymes and other constituents present in reagents for cholesterol analysis. Such a standard is biocompatible. stable, and safe and offers an excellent alternative to the utilization of organic solvents or detergents.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/30771/1/0000422.pd
    corecore