1,002 research outputs found

    The Royal College of Ophthalmologists' National Ophthalmology Database study of cataract surgery: Report 7, immediate sequential bilateral cataract surgery in the UK: Current practice and patient selection.

    Get PDF
    BACKGROUND: Cataract extraction is the most frequently performed surgical intervention in the world and demand is rising due to an ageing demography. One option to address this challenge is to offer selected patients immediate sequential bilateral cataract surgery (ISBCS). This study aims to investigate patient and operative characteristics for ISBCS and delayed bilateral cataract surgery (DSCS) in the UK. METHODS: Data were analysed from the Royal College of Ophthalmologists' National Ophthalmology Database Audit (NOD) of cataract surgery. Eligible patients were those undergoing bilateral cataract extraction from centres with a record of at least one ISBCS operation between 01/04/2010 and 31/08/2018. Variable frequency comparison was undertaken with chi-square tests. RESULTS: During the study period, 1073 patients had ISBCS and 248,341 DSCS from 73 centres. A higher proportion of ISBCS patients were unable to lie flat (11.3% vs. 1.8%; p < 0.001), unable to cooperate (9.7% vs. 2.7%; p < 0.001); underwent general anaesthesia (58.7% vs. 6.6% (p < 0.001)); had brunescent/white/mature cataracts (odds ratio (OR) 5.118); no fundal view/vitreous opacities (OR 8.381); had worse pre-operative acuity 0.60 LogMAR ISBCS vs. 0.50 (first) and 0.40 (second eye) DSCS and were younger (mean ages, 71.5 vs. 75.6 years; p < 0.001). Posterior capsular rupture (PCR) rates adjusted for case complexity were comparable (0.98% ISBCS and 0.78% DSCS). CONCLUSIONS: ISBCS was performed on younger patients, with difficulty cooperating and lying flat, worse pre-operative vision, higher rates of known PCR risk factors and more frequent use of general anaesthesia than DSCS in centres recorded on NOD

    Genotoxicity of multi-walled carbon nanotubes at occupationally relevant doses

    Get PDF
    Carbon nanotubes are commercially-important products of nanotechnology; however, their low density and small size makes carbon nanotube respiratory exposures likely during their production or processing. We have previously shown mitotic spindle aberrations in cultured primary and immortalized human airway epithelial cells exposed to single-walled carbon nanotubes (SWCNT). In this study, we examined whether multi-walled carbon nanotubes (MWCNT) cause mitotic spindle damage in cultured cells at doses equivalent to 34 years of exposure at the NIOSH Recommended Exposure Limit (REL). MWCNT induced a dose responsive increase in disrupted centrosomes, abnormal mitotic spindles and aneuploid chromosome number 24 hours after exposure to 0.024, 0.24, 2.4 and 24 Îźg/cm2 MWCNT. Monopolar mitotic spindles comprised 95% of disrupted mitoses. Three-dimensional reconstructions of 0.1 Îźm optical sections showed carbon nanotubes integrated with microtubules, DNA and within the centrosome structure. Cell cycle analysis demonstrated a greater number of cells in S-phase and fewer cells in the G2 phase in MWCNT-treated compared to diluent control, indicating a G1/S block in the cell cycle. The monopolar phenotype of the disrupted mitotic spindles and the G1/S block in the cell cycle is in sharp contrast to the multi-polar spindle and G2 block in the cell cycle previously observed following exposure to SWCNT. One month following exposure to MWCNT there was a dramatic increase in both size and number of colonies compared to diluent control cultures, indicating a potential to pass the genetic damage to daughter cells. Our results demonstrate significant disruption of the mitotic spindle by MWCNT at occupationally relevant exposure levels

    Real-time PCR-based assay to quantify the relative amount of human and mouse tissue present in tumor xenografts

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Xenograft samples used to test anti-cancer drug efficacies and toxicities in vivo contain an unknown mix of mouse and human cells. Evaluation of drug activity can be confounded by samples containing large amounts of contaminating mouse tissue. We have developed a real-time quantitative polymerase chain reaction (qPCR) assay using TaqMan technology to quantify the amount of mouse tissue that is incorporated into human xenograft samples.</p> <p>Results</p> <p>The forward and reverse primers bind to the same DNA sequence in the human and the mouse genome. Using a set of specially designed fluorescent probes provides species specificity. The linearity and sensitivity of the assay is evaluated using serial dilutions of single species and heterogeneous DNA mixtures. We examined many xenograft samples at various in vivo passages, finding a wide variety of human:mouse DNA ratios. This variation may be influenced by tumor type, number of serial passages in vivo, and even which part of the tumor was collected and used in the assay.</p> <p>Conclusions</p> <p>This novel assay provides an accurate quantitative assessment of human and mouse content in xenograft tumors. This assay can be performed on aberrantly behaving human xenografts, samples used in bioinformatics studies, and periodically for tumor tissue frequently grown by serial passage in vivo.</p

    Developing decision support tools incorporating personalised predictions of likely visual benefit versus harm for cataract surgery:research programme

    Get PDF
    Background Surgery for established cataract is highly cost-effective and uncontroversial, yet uncertainty remains for individuals about when to proceed and when to delay surgery during the earlier stages of cataract. Objective We aimed to improve decision-making for cataract surgery through the development of evidence-based clinical tools that provide general information and personalised risk/benefit information. Design We used a mixed methodology consisting of four work packages. Work package 1 involved the development and psychometric validation of a brief, patient self-reported measure of visual difficulty from cataract and its relief from surgery, named Cataract Patient-Reported Outcome Measure, five items (Cat-PROM5). Work package 2 involved the review and refinement of risk models for adverse surgical events (posterior capsule rupture and visual acuity loss related to cataract surgery). Work package 3 involved the development of prediction models for the Cat-PROM5-based self-reported outcomes from a cohort study of 1500 patients; assessment of the validity of preference-based health economic indices for cataract surgery and the calibration of these to Cat-PROM5; assessment of patients’ and health-care professionals’ views on risk–benefit presentation formats, the perceived usefulness of Cat-PROM5, the value of personalised risk–benefit information, high-value information items and shared decision-making; development of cataract decision aid frequently asked questions, incorporation of personalised estimates of risks and benefits; and development of a cataract decision quality measure to assess the quality of decision-making. Work package 4 involved a mixed-methods feasibility study for a fully powered randomised controlled trial of the use of the cataract decision aid and a qualitative study of discordant or mismatching perceptions of outcome between patients and health-care professionals. Setting Four English NHS recruitment centres were involved: Bristol (lead centre), Brighton, Gloucestershire and Torbay. Multicentre NHS cataract surgery data were obtained from the National Ophthalmology Database. Participants Work package 1 – participants (n = 822) were from all four centres. Work package 2 – electronic medical record data were taken from the National Ophthalmology Database (final set > 1M operations). Work package 3 – cohort study participants were from Bristol (n = 1200) and Gloucestershire (n = 300); qualitative and development work was undertaken with patients and health-care professionals from all four centres. Work package 4 – Bristol, Brighton and Torbay participated in the recruitment of patients (n = 42) for the feasibility trial and recruitment of health-care professionals for the qualitative elements. Interventions For the feasibility trial, the intervention was the use of the cataract decision aid, incorporating frequently asked questions and personalised estimations of both adverse outcomes and self-reported benefit. Main outcome measures There was a range of quantitative and qualitative outcome measures: questionnaire psychometric performance metrics, risk indicators of adverse surgical events and visual outcome, predictors of self-reported outcome following cataract surgery, patient and health-care practitioner views, health economic calibration measures and randomised controlled trial feasibility measures. Data sources The data sources were patient self-reported questionnaire responses, study clinical data collection forms, recorded interviews with patients and health-care professionals, and anonymised National Ophthalmology Database data. Results Work package 1 – Cat-PROM5 was developed and validated with excellent to good psychometric properties (Rasch reliability 0.9, intraclass correlation repeatability 0.9, unidimensionality with residual eigenvalues ≤ 1.5) and excellent responsiveness to surgical intervention (Cohen delta –1.45). Work package 2 – earlier risk models for posterior capsule rupture and visual acuity loss were broadly affirmed (C-statistic for posterior capsule rupture 0.64; visual acuity loss 0.71). Work package 3 – the Cat-PROM5-based self-reported outcome regression models were derived based on 1181 participants with complete data (R2 ≈ 30% for each). Of the four preference-based health economic indices assessed, two demonstrated reasonable performance. Cat-PROM5 was successfully calibrated to health economic indices; adjusted limited dependent variable mixture models offered good to excellent fit (root-mean-square error 0.10–0.16). The personalised quantitative risk information was generally perceived as beneficial. A cataract decision aid and cataract decision quality measure were successfully developed based on the views of patients and health-care professionals. Work package 4 – data completeness was good for the feasibility study primary and secondary variables both before and after intervention/surgery (data completeness range 100–88%). Considering ability to recruit, the sample size required, instrumentation and availability of necessary health economic data, a fully powered randomised controlled trial (patients, n = 800, effect size 0.2 standard deviations, power 80%; p = 0.05) of the cataract decision aid would be feasible following psychometric refinement of the primary outcome (the cataract decision quality measure). The cataract decision aid was generally well-received by patients and health-care professionals, with cautions raised regarding perceived time and workload barriers. Discordant outcomes mostly related to patient dissatisfaction, with no clinical problem found. Limitations The National Ophthalmology Database data are expected to include some errors (mitigated by large multicentre data aggregations). The feasibility randomised controlled trial primary outcome (the cataract decision quality measure) displayed psychometric imperfections requiring refinement. The clinical occurrence of discordant outcomes is uncommon and the study team experienced difficulty identifying patients in this situation. Future work Future work could include regular review of the risk models for adverse outcomes to ensure currency, and the technical precision of complex-numbers analysis of refractive outcome to invite opportunities to improve post-operative spectacle-free vision. In addition, a fully powered randomised controlled trial of the cataract decision aid would be feasible, following psychometric refinement of the primary outcome (the cataract decision quality measure); this would clarify its potential role in routine service delivery. Conclusions In this research programme, evidence-based clinical tools have been successfully developed to improve pre-operative decision-making in cataract surgery. These include a psychometrically robust, patient-reported outcome measure (Cat-PROM5); prediction models for patient self-reported outcomes using Cat-PROM5; prediction models for clinically adverse surgical events and adverse visual acuity outcomes; and a cataract decision aid with relevant general information and personalised risk/benefit predictions. In addition, the successful mapping of Cat-PROM5 to existing health economic indices was achieved and the performances of indices were assessed in patients undergoing cataract surgery. A future full-powered randomised controlled trial of the cataract decision aid would be feasible (patients, n = 800, effect size 0.2 standard deviations, power 80%; p = 0.05). Trial registration This trial is registered as ISRCTN11309852. Funding This project was funded by the National Institute for Health and Care Research (NIHR) Programme Grants for Applied Research programme and will be published in full in Programme Grants for Applied Research; Vol. 10, No. 9. See the NIHR Journals Library website for further project information

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE

    Search for New Physics with Jets and Missing Transverse Momentum in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for new physics is presented based on an event signature of at least three jets accompanied by large missing transverse momentum, using a data sample corresponding to an integrated luminosity of 36 inverse picobarns collected in proton--proton collisions at sqrt(s)=7 TeV with the CMS detector at the LHC. No excess of events is observed above the expected standard model backgrounds, which are all estimated from the data. Exclusion limits are presented for the constrained minimal supersymmetric extension of the standard model. Cross section limits are also presented using simplified models with new particles decaying to an undetected particle and one or two jets

    Combined search for the quarks of a sequential fourth generation

    Get PDF
    Results are presented from a search for a fourth generation of quarks produced singly or in pairs in a data set corresponding to an integrated luminosity of 5 inverse femtobarns recorded by the CMS experiment at the LHC in 2011. A novel strategy has been developed for a combined search for quarks of the up and down type in decay channels with at least one isolated muon or electron. Limits on the mass of the fourth-generation quarks and the relevant Cabibbo-Kobayashi-Maskawa matrix elements are derived in the context of a simple extension of the standard model with a sequential fourth generation of fermions. The existence of mass-degenerate fourth-generation quarks with masses below 685 GeV is excluded at 95% confidence level for minimal off-diagonal mixing between the third- and the fourth-generation quarks. With a mass difference of 25 GeV between the quark masses, the obtained limit on the masses of the fourth-generation quarks shifts by about +/- 20 GeV. These results significantly reduce the allowed parameter space for a fourth generation of fermions.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore