1,207 research outputs found

    Precise control of phase transformation process in lead zirconate titanate thin films by focused line-beam scanning

    Get PDF
    Phase transformation and grain growth processes of lead zirconate titanate (PZT) thin films have been precisely controlled by using focused line-beam scanning. The authors promoted the lateral crystallization of PZT grains by controlling a nucleation process and increasing the size of single grains to be as large as 40 μm in length. Focused line-beam scanning allows for the selective growth and crystallization of large PZT grains on predetermined nucleation sites. The high growth rate of the selected PZT grains was attributed to successive suppression of undesirable nucleation except at predetermined positions when pretreated PZT films were exposed to the focused line beam. © 2007 American Institute of Physics

    Photoluminescent characteristics of Ni-catalyzed GaN nanowires

    Get PDF
    The authors report on time-integrated and time-resolved photoluminescence (PL) of GaN nanowires grown by the Ni-catalyst-assisted vapor-liquid-solid method. From PL spectra of Ni-catalyzed GaN nanowires at 10 K, several PL peaks were observed at 3.472, 3.437, and 3.266 eV, respectively. PL peaks at 3.472 and 3.266 eV are attributed to neutral-donor-bound excitons and donor-acceptor pair, respectively. Furthermore, according to the results from temperature-dependent and time-resolved PL measurements, the origin of the PL peak at 3.437 eV is also discussed. (c) 2006 American Institute of Physics.X1147sciescopu

    Analysis of Slab and Slab Heater Cover in a Compact Endless Cast and Rolling Mill Process using Finite Element Methods

    Get PDF
    Compact Endless cast and rolling Mill (CEM) processes were developed and used to fabricate steel products such as steel slabs. However, the coiling furnace in this process was very expensive, so a new layout was suggested. As the coiling furnace was removed, the interval among the slab heaters had to be increased. This led to a temperature drop in the slab. The temperature distribution of the slab impacts quality, so new layout was developed. This paper presents a Finite Element Method (FEM) simulation of thermal behavior in the slab employing slab heater covers. All of the simulation results were verified by comparing them with experimental results. The slab moving distance at which the temperature was saturated during the process was determined to consider the steady-state and analyze the temperature distribution of the slab and slab heater. Those results revealed that the efficiency of heat conservation increased by more than 50% using the slab heater cover. Finally, a sensitivity analysis of the slab heater cover was conducted with respect to the cover design. The effects of insulator thickness, the gap distance between the slab and cover, and material parameters such as density, and specific heat were investigated to optimize the design of the slab heater cover to produce the best quality slab.11Ysciescopuskc

    Proteins identification of wheat-rye translocation lines by MALDI-TOF-TOF mass spectrometry and ESI-QTOF/MS

    Get PDF
    OBJECTIVE: To examine the relationship between Timed Up and Go (TUG) performance, verbal executive function (EF) performance, and quality-of-life (QOL) measures in Parkinson's disease (PD). DESIGN: Cross-sectional. SETTING: Sixteen movement disorder centers from across the United States. PARTICIPANTS: Patients with PD (N=1964). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: TUG test, immediate and delayed 5-word recall, verbal fluency, PD QOL Questionnaire. RESULTS: TUG performance and verbal EF performance were significantly associated with, and predictors of, QOL measures, having the greatest association and predictability with the mobility domain of the QOL measures. CONCLUSIONS: The TUG test and verbal EF tests have QOL correlates, making the combined evaluation of mobility, cognitive, and QOL decline a potential examination tool to evaluate the sequelae of PD

    The K2K SciBar Detector

    Get PDF
    A new near detector, SciBar, for the K2K long-baseline neutrino oscillation expe riment was installed to improve the measurement of neutrino energy spectrum and to study neutrino interactions in the energy region around 1 GeV. SciBar is a 'fully active' tracking detector with fine segmentation consisting of plastic scintillator bars. The detector was constructed in summer 2003 and is taking data since October 2003. The basic design and initial performance is presented.Comment: 7 pages, 4figures, Contributed to Proceedings of the 10th Vienna Conference on Instrumentation, Vienna, February 16-21, 200

    Short-term costs of conventional vs laparoscopic assisted surgery in patients with colorectal cancer (MRC CLASICC trial)

    Get PDF
    The short-term clinical results of the CLASICC trial indicated that clinical outcomes were similar between laparoscopic and open approaches. This study presents the short-term (3 month) cost analysis undertaken on a subset of patients entered into the CLASICC trial (682 of 794 patients). As expected the costs associated with the operation were higher in the 452 patients randomised to laparoscopic surgery (lap) compared with the 230 randomised to open procedure (open), £1703 vs £1386. This was partially offset by the other hospital (nontheatre) costs, which were lower in the lap group (£2930 vs £3176). The average cost to individuals for reoperations was higher in the lap group (£762 vs £553). Overall costs were slightly higher in the lap group (£6899 vs £6631), with mean difference of £268 (95%CI −689 to 1457). Sensitivity analysis made little difference to these results. The cost of rectal surgery was higher than for colon, for lap (£8259 vs £5586) and open procedures (£7820 vs £5503). The short-term cost analysis for the CLASICC trial indicates that the costs of either laparoscopic or open procedure were similar, lap surgery costing marginally more on average than open surgery

    Display of probability densities for data from a continuous distribution

    Get PDF
    Based on cumulative distribution functions, Fourier series expansion and Kolmogorov tests, we present a simple method to display probability densities for data drawn from a continuous distribution. It is often more efficient than using histograms.Comment: 5 pages, 4 figures, presented at Computer Simulation Studies XXIV, Athens, GA, 201

    Operative blood loss and use of blood products after full robotic and conventional low anterior resection with total mesorectal excision for treatment of rectal cancer

    Get PDF
    To date, no studies have investigated the estimated blood loss (EBL) after full robotic low anterior resection (R-LAR) in a case-matched model, comparing it with the conventional open approach (O-LAR). Forty-nine patients in the R-LAR and 105 in the O-LAR group were matched for age, gender, BMI (body mass index), ASA (American Society of Anesthesiology) class, tumor–node–metastasis (TNM) classification and UICC (Union for International Cancer Control) stage, distance of the lower edge of the tumor from the anal verge, presence of comorbidities, and preoperative hemoglobin (Hb). EBL was significantly higher in the O-LAR group (P < 0.001); twelve units of packed red blood cells were globally transfused in the O-LAR group, compared to one unit only in the R-LAR (P = 0.051). A significantly higher postoperative Hb drop (3.0 vs. 2.4 g/dL, P = 0.015) was registered in the O-LAR patients. The length of hospital stay was much lower for the R-LAR group (8.4 vs. 12.4 days, P < 0.001). The number of harvested lymph nodes (17.4 vs. 13.5, P = 0.006) and extent of distal margin (2.9 vs. 1.9 cm, P < 0.001) were significantly higher in the R-LAR group. Open surgery was confirmed as the sole variable significantly associated (P < 0.001) with blood loss (odds ratio = 4.41, 95% CI 2.06–9.43). It was a confirmed prognosticator of blood loss (P = 0.006) when a preoperative clinical predictive model was built, using multivariate analysis (odds ratio = 3.95, 95% CI 1.47–10.6). In conclusion, R-LAR produced less operative blood loss and less drop in postoperative hemoglobin when compared to O-LAR. Other clinically relevant outcomes were similar or superior to O-LAR
    corecore