103 research outputs found

    Can latent heat safely warm blood? – in vitro testing of a portable prototype blood warmer

    Get PDF
    This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Background Trauma/retrieval patients are often in shock and hypothermic. Treatment of such patients usually involves restoring their blood volume with transfusion of blood (stored at 2°C – 6°C) and/or crystalloids or colloids (stored at ambient temperature). Rapid infusion of these cold fluids can worsen or even induce hypothermia in these patients. Warming of intravenous fluids at accident sites has traditionally been difficult due to a lack of suitable portable fluid warmers that are not dependent on mains electrical or battery power. If latent heat, the heat released when a liquid solidifies (an inherently temperature limiting process) can warm intravenous fluids, portable devices without a reliance on electrical energy could be used to reduce the incidence of hypothermia in trauma patients. Methods Rapid infusion of red cells into patients was timed to sample typical clinical flow rates. An approved dry heat blood warmer was compared with a prototype blood warmer using a supercooled liquid latent heat storage material, to warm red cells whilst monitoring inlet and outlet temperatures. To determine the effect of warming on red cell integrity compared to the normal storage lesion of blood, extracellular concentrations of potassium, lactate dehydrogenase and haemoglobin were measured in blood which had been warmed after storage at 2°C – 6°C for 1 to 42 days. Results A prototype latent heat fluid warmer consistently warmed red cells from approximately 4°C to approximately 35°C at typical clinical flow rates. Warming of stored blood with latent heat did not affect red cell integrity more than the approved dry heat blood warmer. Conclusion Using latent heat as an energy source can satisfactorily warm cold blood or other intravenous fluids to near body temperature, without any adverse affects

    Monitoring Virologic Responses to Antiretroviral Therapy in HIV-Infected Adults in Kenya: Evaluation of a Low-Cost Viral Load Assay

    Get PDF
    A key advantage of monitoring HIV viral load (VL) in persons receiving antiretroviral therapy (ART) is the ability to detect virologic failure before clinical deterioration or resistance occurs. Detection of virologic failure will help clarify the need for enhanced adherence counseling or a change to second- line therapy. Low-cost, locally performable alternates to expensive VL assays are needed where resources are limited.We monitored the response to 48-week ART in 100 treatment-naĂŻve Kenyan adults using a low-cost VL measurement, the Cavidi reverse transcriptase (RT) assay and gold-standard assays, Roche RNA PCR and Bayer Versant HIV-1 RNA (bDNA) assays. In Altman-Bland plots, the mean difference in viral loads between the three assays was small (<0.5 log(10) copies/mL). However, the limits of agreement between the methods exceeded the biologically relevant change of 0.5 log copies/ml. Therefore, the RT assay cannot be used interchangeably with the other assays to monitor individual patients. The RT assay was 100% sensitive in detecting viral loads of > or =400 copies/ml compared to gold-standard assays. After 24 weeks of treatment, viral load measured by the RT assay was undetectable in 95% of 65 patients with undetectable RNA PCR VL (<400 copies/ml), 90% of 67 patients with undetectable bDNA VL, and 96% of 57 patients with undetectable VL in both RNA PCR and bDNA assays. The negative predictive value of the RT assay was 100% compared to either assay; the positive predictive value was 86% compared to RNA PCR and 70% compared to bDNA.The RT assay compared well with gold standard assays. Our study highlights the importance of not interchanging viral load assays when monitoring an individual patient. Furthermore, the RT assay may be limited by low positive predictive values when used in populations with low prevalence of virologic failure

    Light pollution: The possible consequences of excessive illumination on retina

    Get PDF
    Light is the visible part of the electromagnetic radiation within a range of 380-780 nm; (400-700 on primates retina). In vertebrates, the retina is adapted to capturing light photons and transmitting this information to other structures in the central nervous system. In mammals, light acts directly on the retina to fulfill two important roles: (1) the visual function through rod and cone photoreceptor cells and (2) non-image forming tasks, such as the synchronization of circadian rhythms to a 24 h solar cycle, pineal melatonin suppression and pupil light reflexes. However, the excess of illumination may cause retinal degeneration or accelerate genetic retinal diseases. In the last century human society has increased its exposure to artificial illumination, producing changes in the Light/Dark cycle, as well as in light wavelengths and intensities. Although, the consequences of unnatural illumination or light pollution have been underestimated by modern society in its way of life, light pollution may have a strong impact on people's health. The effects of artificial light sources could have direct consequences on retinal health. Constant exposure to different wavelengths and intensities of light promoted by light pollution may produce retinal degeneration as a consequence of photoreceptor or retinal pigment epithelium cells death. In this review we summarize the different mechanisms of retinal damage related to the light exposure, which generates light pollution.Fil: Contin, Maria Ana. Consejo Nacional de Investigaciones CientĂ­ficas y TĂŠcnicas. Centro CientĂ­fico TecnolĂłgico Conicet - CĂłrdoba. Centro de Investigaciones en QuĂ­mica BiolĂłgica de CĂłrdoba. Universidad Nacional de CĂłrdoba. Facultad de Ciencias QuĂ­micas. Centro de Investigaciones en QuĂ­mica BiolĂłgica de CĂłrdoba; ArgentinaFil: Benedetto, MarĂ­a Mercedes. Consejo Nacional de Investigaciones CientĂ­ficas y TĂŠcnicas. Centro CientĂ­fico TecnolĂłgico Conicet - CĂłrdoba. Centro de Investigaciones en QuĂ­mica BiolĂłgica de CĂłrdoba. Universidad Nacional de CĂłrdoba. Facultad de Ciencias QuĂ­micas. Centro de Investigaciones en QuĂ­mica BiolĂłgica de CĂłrdoba; ArgentinaFil: Quinteros Quintana, MarĂ­a Luz. Consejo Nacional de Investigaciones CientĂ­ficas y TĂŠcnicas. Centro CientĂ­fico TecnolĂłgico Conicet - CĂłrdoba. Centro de Investigaciones en QuĂ­mica BiolĂłgica de CĂłrdoba. Universidad Nacional de CĂłrdoba. Facultad de Ciencias QuĂ­micas. Centro de Investigaciones en QuĂ­mica BiolĂłgica de CĂłrdoba; ArgentinaFil: Guido, Mario Eduardo. Consejo Nacional de Investigaciones CientĂ­ficas y TĂŠcnicas. Centro CientĂ­fico TecnolĂłgico Conicet - CĂłrdoba. Centro de Investigaciones en QuĂ­mica BiolĂłgica de CĂłrdoba. Universidad Nacional de CĂłrdoba. Facultad de Ciencias QuĂ­micas. Centro de Investigaciones en QuĂ­mica BiolĂłgica de CĂłrdoba; Argentin

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Group differences in physician responses to handheld presentation of clinical evidence: a verbal protocol analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To identify individual differences in physicians' needs for the presentation of evidence resources and preferences for mobile devices.</p> <p>Methods</p> <p>Within-groups analysis of responses to semi-structured interviews. Interviews consisted of using prototypes in response to task-based scenarios. The prototypes were implemented on two different form factors: a tablet style PC and a pocketPC. Participants were from three user groups: general internists, family physicians and medicine residents, and from two different settings: urban and semi-urban. Verbal protocol analysis, which consists of coding utterances, was conducted on the transcripts of the testing sessions. Statistical relationships were investigated between staff physicians' and residents' background variables, self-reported experiences with the interfaces, and verbal code frequencies.</p> <p>Results</p> <p>47 physicians were recruited from general internal medicine, family practice clinics and a residency training program. The mean age of participants was 42.6 years. Physician specialty had a greater effect on device and information-presentation preferences than gender, age, setting or previous technical experience. Family physicians preferred the screen size of the tablet computer and were less concerned about its portability. Residents liked the screen size of the tablet, but preferred the portability of the pocketPC. Internists liked the portability of the pocketPC, but saw less advantage to the large screen of the tablet computer (F[2,44] = 4.94, p = .012).</p> <p>Conclusion</p> <p>Different types of physicians have different needs and preferences for evidence-based resources and handheld devices. This study shows how user testing can be incorporated into the process of design to inform group-based customization.</p

    EphA2-receptor deficiency exacerbates myocardial infarction and reduces survival in hyperglycemic mice

    Get PDF
    Background We have previously shown that EphrinA1/EphA expression profile changes in response to myocardial infarction (MI), exogenous EphrinA1-Fc administration following MI positively influences wound healing, and that deletion of the EphA2 Receptor (EphA2-R) exacerbates injury and remodeling. To determine whether or not ephrinA1-Fc would be of therapeutic value in the hyperglycemic infarcted heart, it is critical to evaluate how ephrinA1/EphA signaling changes in the hyperglycemic myocardium in response to MI. Methods Streptozotocin (STZ)-induced hyperglycemia in wild type (WT) and EphA2-receptor mutant (EphA2-R-M) mice was initiated by an intraperitoneal injection of STZ (150 mg/kg) 10 days before surgery. MI was induced by permanent ligation of the left anterior descending coronary artery and analyses were performed at 4 days post-MI. ANOVAs with Student-Newman Keuls multiple comparison post-hoc analysis illustrated which groups were significantly different, with significance of at least p < 0.05. Results Both WT and EphA2-R-M mice responded adversely to STZ, but only hyperglycemic EphA2-R-M mice had lower ejection fraction (EF) and fractional shortening (FS). At 4 days post-MI, we observed greater post-MI mortality in EphA2-R-M mice compared with WT and this was greater still in the EphA2-R-M hyperglycemic mice. Although infarct size was greater in hyperglycemic WT mice vs normoglycemic mice, there was no difference between hyperglycemic EphA2-R-M mice and normoglycemic EphA2-R-M mice. The hypertrophic response that normally occurs in viable myocardium remote to the infarct was noticeably absent in epicardial cardiomyocytes and cardiac dysfunction worsened in hyperglycemic EphA2-R-M hearts post-MI. The characteristic interstitial fibrotic response in the compensating myocardium remote to the infarct also did not occur in hyperglycemic EphA2-R-M mouse hearts to the same extent as that observed in the hyperglycemic WT mouse hearts. Differences in neutrophil and pan-leukocyte infiltration and serum cytokines implicate EphA2-R in modulation of injury and the differences in ephrinA1 and EphA6-R expression in governing this are discussed. Conclusions We conclude that EphA2-mutant mice are more prone to hyperglycemia-induced increased injury, decreased survival, and worsened LV remodeling due to impaired wound healing

    CMS Data Processing Workflows during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Commissioning of the CMS high-level trigger with cosmic rays

    Get PDF
    This is the Pre-print version of the Article. The official published version of the paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS High-Level Trigger (HLT) is responsible for ensuring that data samples with potentially interesting events are recorded with high efficiency and good quality. This paper gives an overview of the HLT and focuses on its commissioning using cosmic rays. The selection of triggers that were deployed is presented and the online grouping of triggered events into streams and primary datasets is discussed. Tools for online and offline data quality monitoring for the HLT are described, and the operational performance of the muon HLT algorithms is reviewed. The average time taken for the HLT selection and its dependence on detector and operating conditions are presented. The HLT performed reliably and helped provide a large dataset. This dataset has proven to be invaluable for understanding the performance of the trigger and the CMS experiment as a whole.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Identification and Filtering of Uncharacteristic Noise in the CMS Hadron Calorimeter

    Get PDF
    VertaisarvioitupeerReviewe
    • …