98 research outputs found
Development of Wireless Techniques in Data and Power Transmission - Application for Particle Physics Detectors
Wireless techniques have developed extremely fast over the last decade and
using them for data and power transmission in particle physics detectors is not
science- fiction any more. During the last years several research groups have
independently thought of making it a reality. Wireless techniques became a
mature field for research and new developments might have impact on future
particle physics experiments. The Instrumentation Frontier was set up as a part
of the SnowMass 2013 Community Summer Study [1] to examine the instrumentation
R&D for the particle physics research over the coming decades: {\guillemotleft}
To succeed we need to make technical and scientific innovation a priority in
the field {\guillemotright}. Wireless data transmission was identified as one
of the innovations that could revolutionize the transmission of data out of the
detector. Power delivery was another challenge mentioned in the same report. We
propose a collaboration to identify the specific needs of different projects
that might benefit from wireless techniques. The objective is to provide a
common platform for research and development in order to optimize effectiveness
and cost, with the aim of designing and testing wireless demonstrators for
large instrumentation systems
n-XYTER: A CMOS read-out ASIC for a new generation of high rate multichannel counting mode neutron detectors
For a new generation of 2-D neutron detectors developed in the framework of the EU NMI3 project DETNI [1], the 128-channel frontend chip n-XYTER has been designed. To facilitate the reconstruction of single neutron incidence points, the chip has to provide a spatial coordinate (represented by the channel number), as well as time stamp and amplitude information to match the data of x- and y-coordinates. While the random nature of the input signals calls for self-triggered operation of the chip, on-chip derandomisation and sparsi cation is required to exploit the enormous rate capability of these detectors ( 4 106cm2s1). The chosen architecture implements a preampli er driving two shapers with di erent time constants per channel. The faster shaper drives a single-pulse discriminator with subsequent time-walk compensation. The output of this circuit is used to latch a 14-bit time stamp with a 2 ns resolution and to enable a peak detector circuit fed by the slower shaper branch. The analogue output of the peak detector as well as the time stamp are stored in a 4-stage FIFO for derandomisation. The readout of these FIFOs is accomplished by a token-ring based multiplexer working at 32 MHz, which accounts for further derandomisation, sparsi cation and dynamic bandwidth distribution. The chip was submitted for manufacturing in AMS's C35B4M3 0.35µm CMOS technology in June 2006
Transition Radiation Spectra of Electrons from 1 to 10 GeV/c in Regular and Irregular Radiators
We present measurements of the spectral distribution of transition radiation
generated by electrons of momentum 1 to 10 GeV/c in different radiator types.
We investigate periodic foil radiators and irregular foam and fiber materials.
The transition radiation photons are detected by prototypes of the drift
chambers to be used in the Transition Radiation Detector (TRD) of the ALICE
experiment at CERN, which are filled with a Xe, CO2 (15 %) mixture. The
measurements are compared to simulations in order to enhance the quantitative
understanding of transition radiation production, in particular the momentum
dependence of the transition radiation yield.Comment: 18 pages, 15 figures, submitted to Nucl. Instr. Meth. Phys. Res.
Energy loss of pions and electrons of 1 to 6 GeV/c in drift chambers operated with Xe,CO2(15%)
We present measurements of the energy loss of pions and electrons in drift
chambers operated with a Xe,CO2(15%) mixture. The measurements are carried out
for particle momenta from 1 to 6 GeV/c using prototype drift chambers for the
ALICE TRD. Microscopic calculations are performed using input parameters
calculated with GEANT3. These calculations reproduce well the measured average
and most probable values for pions, but a higher Fermi plateau is required in
order to reproduce our electron data. The widths of the measured distributions
are smaller for data compared to the calculations. The electron/pion
identification performance using the energy loss is also presented.Comment: 15 pages, 10 figures, accepted for publication in Nucl.Instrum.Meth.
Position Reconstruction in Drift Chambers operated with Xe, CO2 (15%)
We present measurements of position and angular resolution of drift chambers
operated with a Xe,CO(15%) mixture. The results are compared to Monte Carlo
simulations and important systematic effects, in particular the dispersive
nature of the absorption of transition radiation and non-linearities, are
discussed. The measurements were carried out with prototype drift chambers of
the ALICE Transition Radiation Detector, but our findings can be generalized to
other drift chambers with similar geometry, where the electron drift is
perpendicular to the wire planes.Comment: 30 pages, 18 figure
Space charge in drift chambers operated with the Xe,CO2(15%) mixture
Using prototype modules of the ALICE Transition Radiation Detector we
investigate space charge effects and the dependence of the pion rejection
performance on the incident angle of the ionizing particle. The average pulse
height distributions in the drift chambers operated with the Xe,CO2(15%)
mixture provide quantitative information on the gas gain reduction due to space
charge accumulating during the drift of the primary ionization. Our results
demonstrate that the pion rejection performance of a TRD is better for tracks
which are not at normal incidence to the anode wires. We present detailed
simulations of detector signals, which reproduce the measurements and lend
strong support to our interpretation of the measurements in terms of space
charge effects.Comment: 18 pages, 10 figures, accepted for publication in Nucl.Instrum.Meth.
A. Data files available at http://www-alice.gsi.de/tr
Transition Radiation Spectroscopy with Prototypes of the ALICE TRD
We present measurements of the transition radiation (TR) spectrum produced in
an irregular radiator at different electron momenta. The data are compared to
simulations of TR from a regular radiator.Comment: 4 pages, 5 Figures, Proceedings for "TRDs for the 3rd millennium"
(Sept. 4-7, 2003, Bari, Italy
The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events
The design, construction, and commissioning of the ALICE Time-Projection
Chamber (TPC) is described. It is the main device for pattern recognition,
tracking, and identification of charged particles in the ALICE experiment at
the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and
is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we describe in detail the design considerations for this
detector for operation in the extreme multiplicity environment of central
Pb--Pb collisions at LHC energy. The implementation of the resulting
requirements into hardware (field cage, read-out chambers, electronics),
infrastructure (gas and cooling system, laser-calibration system), and software
led to many technical innovations which are described along with a presentation
of all the major components of the detector, as currently realized. We also
report on the performance achieved after completion of the first round of
stand-alone calibration runs and demonstrate results close to those specified
in the TPC Technical Design Report.Comment: 55 pages, 82 figure
- …