98 research outputs found

    Development of Wireless Techniques in Data and Power Transmission - Application for Particle Physics Detectors

    Full text link
    Wireless techniques have developed extremely fast over the last decade and using them for data and power transmission in particle physics detectors is not science- fiction any more. During the last years several research groups have independently thought of making it a reality. Wireless techniques became a mature field for research and new developments might have impact on future particle physics experiments. The Instrumentation Frontier was set up as a part of the SnowMass 2013 Community Summer Study [1] to examine the instrumentation R&D for the particle physics research over the coming decades: {\guillemotleft} To succeed we need to make technical and scientific innovation a priority in the field {\guillemotright}. Wireless data transmission was identified as one of the innovations that could revolutionize the transmission of data out of the detector. Power delivery was another challenge mentioned in the same report. We propose a collaboration to identify the specific needs of different projects that might benefit from wireless techniques. The objective is to provide a common platform for research and development in order to optimize effectiveness and cost, with the aim of designing and testing wireless demonstrators for large instrumentation systems

    n-XYTER: A CMOS read-out ASIC for a new generation of high rate multichannel counting mode neutron detectors

    Get PDF
    For a new generation of 2-D neutron detectors developed in the framework of the EU NMI3 project DETNI [1], the 128-channel frontend chip n-XYTER has been designed. To facilitate the reconstruction of single neutron incidence points, the chip has to provide a spatial coordinate (represented by the channel number), as well as time stamp and amplitude information to match the data of x- and y-coordinates. While the random nature of the input signals calls for self-triggered operation of the chip, on-chip derandomisation and sparsi cation is required to exploit the enormous rate capability of these detectors ( 4 106cm2s1). The chosen architecture implements a preampli er driving two shapers with di erent time constants per channel. The faster shaper drives a single-pulse discriminator with subsequent time-walk compensation. The output of this circuit is used to latch a 14-bit time stamp with a 2 ns resolution and to enable a peak detector circuit fed by the slower shaper branch. The analogue output of the peak detector as well as the time stamp are stored in a 4-stage FIFO for derandomisation. The readout of these FIFOs is accomplished by a token-ring based multiplexer working at 32 MHz, which accounts for further derandomisation, sparsi cation and dynamic bandwidth distribution. The chip was submitted for manufacturing in AMS's C35B4M3 0.35µm CMOS technology in June 2006

    Transition Radiation Spectra of Electrons from 1 to 10 GeV/c in Regular and Irregular Radiators

    Full text link
    We present measurements of the spectral distribution of transition radiation generated by electrons of momentum 1 to 10 GeV/c in different radiator types. We investigate periodic foil radiators and irregular foam and fiber materials. The transition radiation photons are detected by prototypes of the drift chambers to be used in the Transition Radiation Detector (TRD) of the ALICE experiment at CERN, which are filled with a Xe, CO2 (15 %) mixture. The measurements are compared to simulations in order to enhance the quantitative understanding of transition radiation production, in particular the momentum dependence of the transition radiation yield.Comment: 18 pages, 15 figures, submitted to Nucl. Instr. Meth. Phys. Res.

    Energy loss of pions and electrons of 1 to 6 GeV/c in drift chambers operated with Xe,CO2(15%)

    Full text link
    We present measurements of the energy loss of pions and electrons in drift chambers operated with a Xe,CO2(15%) mixture. The measurements are carried out for particle momenta from 1 to 6 GeV/c using prototype drift chambers for the ALICE TRD. Microscopic calculations are performed using input parameters calculated with GEANT3. These calculations reproduce well the measured average and most probable values for pions, but a higher Fermi plateau is required in order to reproduce our electron data. The widths of the measured distributions are smaller for data compared to the calculations. The electron/pion identification performance using the energy loss is also presented.Comment: 15 pages, 10 figures, accepted for publication in Nucl.Instrum.Meth.

    Position Reconstruction in Drift Chambers operated with Xe, CO2 (15%)

    Full text link
    We present measurements of position and angular resolution of drift chambers operated with a Xe,CO2_2(15%) mixture. The results are compared to Monte Carlo simulations and important systematic effects, in particular the dispersive nature of the absorption of transition radiation and non-linearities, are discussed. The measurements were carried out with prototype drift chambers of the ALICE Transition Radiation Detector, but our findings can be generalized to other drift chambers with similar geometry, where the electron drift is perpendicular to the wire planes.Comment: 30 pages, 18 figure

    Space charge in drift chambers operated with the Xe,CO2(15%) mixture

    Full text link
    Using prototype modules of the ALICE Transition Radiation Detector we investigate space charge effects and the dependence of the pion rejection performance on the incident angle of the ionizing particle. The average pulse height distributions in the drift chambers operated with the Xe,CO2(15%) mixture provide quantitative information on the gas gain reduction due to space charge accumulating during the drift of the primary ionization. Our results demonstrate that the pion rejection performance of a TRD is better for tracks which are not at normal incidence to the anode wires. We present detailed simulations of detector signals, which reproduce the measurements and lend strong support to our interpretation of the measurements in terms of space charge effects.Comment: 18 pages, 10 figures, accepted for publication in Nucl.Instrum.Meth. A. Data files available at http://www-alice.gsi.de/tr

    The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events

    Get PDF
    The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis. In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb--Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report.Comment: 55 pages, 82 figure
    corecore