472 research outputs found

    The POOL Data Storage, Cache and Conversion Mechanism

    Full text link
    The POOL data storage mechanism is intended to satisfy the needs of the LHC experiments to store and analyze the data from the detector response of particle collisions at the LHC proton-proton collider. Both the data rate and the data volumes will largely differ from the past experience. The POOL data storage mechanism is intended to be able to cope with the experiment's requirements applying a flexible multi technology data persistency mechanism. The developed technology independent approach is flexible enough to adopt new technologies, take advantage of existing schema evolution mechanisms and allows users to access data in a technology independent way. The framework consists of several components, which can be individually adopted and integrated into existing experiment frameworks.Comment: Talk from the 2003 Computing in High Energy and Nuclear Physics (CHEP03), La Jolla, Ca, USA, March 2003, 5 pages, PDF, 6 figures. PSN MOKT00

    ArchaeoBIM: dallo scavo al Building Information Modeling di una struttura sepolta. Il caso del tempio tuscanico di Uni a Marzabotto

    Get PDF
    The model of the Tuscanic Temple of Uni in Marzabotto, recently discovered, has been a common ground for engineering and archaeological studies, thanks to the processing of a Building Information Modeling (BIM). Beside the historic and archaeological analysis, the innovation of this study concerns the examination of the Etruscan temple as a three-dimensional building, with the use of technologies which impact on the architectural reliability of the model, and the design of a new method of Experimental Archaeology based on a virtual approach. The uniqueness of this approach lies in the study of original elements at the starting point of the building process, that consist in foundations or spoliated structures (i.e. negative evidences), over the clues from the historical and scientific literature. To better define this distinctive working process, the expression ArchaeoBIM has been proposed. With this expression we underline the common BIM matrix in the data management through integrated analytical models, applied to a particular aspect of the archaeological research

    Persistent storage of non-event data in the CMS databases

    Get PDF
    In the CMS experiment, the non event data needed to set up the detector, or being produced by it, and needed to calibrate the physical responses of the detector itself are stored in ORACLE databases. The large amount of data to be stored, the number of clients involved and the performance requirements make the database system an essential service for the experiment to run. This note describes the CMS condition database architecture, the data-flow and PopCon, the tool built in order to populate the offline databases. Finally, the first results obtained during the 2008 and 2009 cosmic data taking are presented.In the CMS experiment, the non event data needed to set up the detector, or being produced by it, and needed to calibrate the physical responses of the detector itself are stored in ORACLE databases. The large amount of data to be stored, the number of clients involved and the performance requirements make the database system an essential service for the experiment to run. This note describes the CMS condition database architecture, the data-flow and PopCon, the tool built in order to populate the offline databases. Finally, the first experience obtained during the 2008 and 2009 cosmic data taking are presented

    Measurement of the branching ratios of the decays Xi0 --> Sigma+ e- nubar and anti-Xi0 --> anti-Sigma+ e+ nu

    Full text link
    From 56 days of data taking in 2002, the NA48/1 experiment observed 6316 Xi0 --> Sigma+ e- nubar candidates (with the subsequent Sigma+ --> p pi0 decay) and 555 anti-Xi0 --> anti-Sigma+ e+ nu candidates with background contamination of 215+-44 and 136+-8 events, respectively. From these samples, the branching ratios BR(Xi0 --> Sigma+ e- nubar)= (2.51+-0.03stat+-0.09syst)E(-4) and BR(anti-Xi0 --> anti-Sigma+ e+ nu)= (2.55+-0.14stat+-0.10syst)E(-4) were measured allowing the determination of the CKM matrix element |Vus| = 0.209+0.023-0.028. Using the Particle Data Group average for |Vus| obtained in semileptonic kaon decays, we measured the ratio g1/f1 = 1.20+-0.05 of the axial-vector to vector form factors.Comment: 16 pages, 11 figures Submitted to Phys.Lett.

    A new measurement of direct CP violation in two pion decays of the neutral kaon

    Get PDF
    The NA48 experiment at CERN has performed a new measurement of direct CP violation, based on data taken in 1997 by simultaneously collecting K_L and K_S decays into pi0pi0 and pi+pi-. The result for the CP violating parameter Re(epsilon'/epsilon) is (18.5 +/- 4.5(stat)} +/- 5.8 (syst))x10^{-4}.Comment: 18 pages, 6 figure

    Measurement of the Ratio Gamma(KL -> pi+ pi-)/Gamma(KL -> pi e nu) and Extraction of the CP Violation Parameter |eta+-|

    Full text link
    We present a measurement of the ratio of the decay rates Gamma(KL -> pi+ pi-)/Gamma(KL -> pi e nu), denoted as Gamma(K2pi)/Gamma(Ke3). The analysis is based on data taken during a dedicated run in 1999 by the NA48 experiment at the CERN SPS. Using a sample of 47000 K2pi and five million Ke3 decays, we find Gamma(K2pi)/Gamma(Ke3) = (4.835 +- 0.022(stat) +- 0.016(syst)) x 10^-3. From this we derive the branching ratio of the CP violating decay KL -> pi+ pi- and the CP violation parameter |eta+-|. Excluding the CP conserving direct photon emission component KL -> pi+ pi- gamma, we obtain the results BR(KL -> pi+ pi-) = (1.941 +- 0.019) x 10^-3 and |eta+-| = (2.223 +- 0.012) x 10^-3.Comment: 20 pages, 7 figures, accepted by Phys. Lett.

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore