3,262 research outputs found

    Capsule impaction presenting as acute small bowel perforation: a case series

    Get PDF
    INTRODUCTION: Perforation caused by capsule endoscopy impaction is extremely rare and, at present, only five cases of perforation from capsule endoscopy impaction are reported in the literature. CASE PRESENTATION: We report here two cases of patients with undiagnosed small bowel stenosis presenting with acute perforation after capsule endoscopy. Strictures in the small bowel were likely the inciting mechanism leading to acute small bowel obstruction and subsequent distension and perforation above the capsule in the area of maximal serosal tension. Case 1 was a 55-year-old Italian woman who underwent capsule endoscopy because of recurrent postprandial cramping pain and iron deficiency anemia, in the setting of negative imaging studies including an abdominal ultrasound, upper endoscopy, colonoscopy and small bowel follow-through radiograph. She developed a symptomatic bowel obstruction approximately 36 hours after ingestion of the capsule. Emergent surgery was performed to remove the capsule, which was impacted at a stenosis due to a previously undiagnosed ileal adenocarcinoma, leading to perforation. Case 2 was a 60-year-old Italian man with recurrent episodes of abdominal pain and diarrhea who underwent capsule endoscopy after conventional modalities, including comprehensive blood and stool studies, computed tomography, an abdominal ultrasound, upper endoscopy, colonoscopy, barium enema and small bowel follow-through, were not diagnostic. Our patient developed abdominal distension, acute periumbilical pain, fever and leukocytosis 20 hours after capsule ingestion. Emergent surgery was performed to remove the capsule, which was impacted at a previously undiagnosed ileal Crohn’s stricture, leading to perforation. CONCLUSIONS: The present report shows that, although the risk of acute complication is very low, the patient should be informed of the risks involved in capsule endoscopy, including the need for emergency surgical exploration

    Confocal Laser Endomicroscopy in the Study of Colonic Mucosa in IBD Patients: A Review

    Get PDF
    Confocal laser endomicroscopy (CLE) is one of several novel methods that provide real-time, high-resolution imaging at a micronscale via endoscopes. CLE and related technologies are often termed “virtual biopsy” as they simulate the images seen in traditional histology. Recently, the use of CLE was reported in the study of colonic mucosa in patients with inflammatory bowel diseases and in particular in patients affected by ulcerative colitis. CLE has the potential to have an important role in management of IBD patients as it can be used to assess the grading of colitis and in detection of microscopic colitis in endoscopically silent segments. Moreover, CLE can be used in surveillance programs especially in high-risk patients. This report aims to evaluate the current data on the application of confocal endomicroscopy in clinical gastroenterology and particularly in the study of colonic mucosa in UC patients

    GW170104: Observation of a 50-Solar-Mass Binary Black Hole Coalescence at Redshift 0.2

    Get PDF
    We describe the observation of GW170104, a gravitational-wave signal produced by the coalescence of a pair of stellar-mass black holes. The signal was measured on January 4, 2017 at 10 11:58.6 UTC by the twin advanced detectors of the Laser Interferometer Gravitational-Wave Observatory during their second observing run, with a network signal-to-noise ratio of 13 and a false alarm rate less than 1 in 70 000 years. The inferred component black hole masses are 31.2-6.0+8.4M\u27 and 19.4-5.9+5.3M (at the 90% credible level). The black hole spins are best constrained through measurement of the effective inspiral spin parameter, a mass-weighted combination of the spin components perpendicular to the orbital plane, χeff=-0.12-0.30+0.21. This result implies that spin configurations with both component spins positively aligned with the orbital angular momentum are disfavored. The source luminosity distance is 880-390+450 Mpc corresponding to a redshift of z=0.18-0.07+0.08. We constrain the magnitude of modifications to the gravitational-wave dispersion relation and perform null tests of general relativity. Assuming that gravitons are dispersed in vacuum like massive particles, we bound the graviton mass to mg≤7.7×10-23 eV/c2. In all cases, we find that GW170104 is consistent with general relativity

    Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up

    Get PDF
    Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated

    Segmental transverse colectomy. Minimally invasive versus open approach: results from a multicenter collaborative study

    Get PDF
    none65noThe role of minimally invasive surgery in the treatment of transverse colon cancer is still controversial. The aim of this study is to investigate the advantages of a totally laparoscopic technique comparing open versus laparoscopic/robotic approach. Three hundred and eighty-eight patients with transverse colon cancer, treated with a segmental colon resection, were retrospectively analyzed. Demographic data, tumor stage, operative time, intraoperative complications, number of harvested lymph nodes and recovery outcomes were recorded. Recurrences and death were also evaluated during the follow-up. No differences were found between conventional and minimally invasive surgery, both for oncological long-term outcomes (recurrence rate p = 0.28; mortality p = 0.62) and postoperative complications (overall rate p = 0.43; anemia p = 0.78; nausea p = 0.68; infections p = 0.91; bleeding p = 0.62; anastomotic leak p = 0.55; ileus p = 0.75). Nevertheless, recovery outcomes showed statistically significant differences in favor of minimally invasive surgery in terms of time to first flatus (p = 0.001), tolerance to solid diet (p = 0.017), time to first mobilization (p = 0.001) and hospital stay (p = 0.004). Compared with laparoscopic approach, robotic surgery showed significantly better results for time to first flatus (p = 0.001), to first mobilization (p = 0.005) and tolerance to solid diet (p = 0.001). Finally, anastomosis evaluation confirmed the superiority of intracorporeal approach which showed significantly better results for time to first flatus (p = 0.001), to first mobilization (p = 0.003) and tolerance to solid diet (p = 0.001); moreover, we recorded a statistical difference in favor of intracorporeal approach for infection rate (p = 0.04), bleeding (p = 0.001) and anastomotic leak (p = 0.03). Minimally invasive approach is safe and effective as the conventional open surgery, with comparable oncological results but not negligible advantages in terms of recovery outcomes. Moreover, we demonstrated that robotic approach may be considered a valid option and an intracorporeal anastomosis should always be preferred.noneMilone, Marco; Degiuli, Maurizio; Velotti, Nunzio; Manigrasso, Michele; Vertaldi, Sara; D'Ugo, Domenico; De Palma, Giovanni Domenico; Dario Bruzzese, Giuseppe Servillo, Giuseppe De Simone, Katia Di Lauro, Silvia Sofia, Marco Ettore Allaix, Mario Morino, Rossella Reddavid, Carlo Alberto Ammirati, Stefano Scabini, Gabriele Anania, Cristina Bombardini, Andrea Barberis, Roberta Longhin, Andrea Belli, Francesco Bianco, Giampaolo Formisano, Giuseppe Giuliani, Paolo Pietro Bianchi, Davide Cavaliere, Leonardo Solaini, Claudio Coco, Gianluca Rizzo, Andrea Coratti, Raffaele De Luca, Michele Simone, Alberto Di Leo, Giovanni De Manzoni, Paola De Nardi, Ugo Elmore, Riccardo Rosati, Andrea Vignali, Paolo Delrio, Ugo Pace, Daniela Rega, Antonio Di Cataldo, Giovanni Li Destri, Annibale Donini, Luigina Graziosi, Andrea Fontana, Michela Mineccia, Sergio Gentilli, Manuela Monni, Mario Guerrieri, Monica Ortenzi, Francesca Pecchini, Micaela Piccoli, Italy. Corrado Pedrazzani, Giulia Turri, Sara Pollesel, Franco Roviello, Marco Rigamonti, Michele Zuolo, Mauro Santarelli, Federica Saraceno, Pierpaolo Sileri Giuseppe Sigismondo Sica, Luigi Siragusa Salvatore Pucciarelli, Matteo ZuinMilone, Marco; Degiuli, Maurizio; Velotti, Nunzio; Manigrasso, Michele; Vertaldi, Sara; D'Ugo, Domenico; De Palma, Giovanni Domenico; Dario Bruzzese, Giuseppe Servillo, Giuseppe De Simone, Katia Di Lauro, Silvia Sofia, Marco Ettore Allaix, Mario Morino, Rossella Reddavid, Carlo Alberto Ammirati, Stefano Scabini, Gabriele Anania, Cristina Bombardini, Andrea Barberis, Roberta Longhin, Andrea Belli, Francesco Bianco, Giampaolo Formisano, Giuseppe Giuliani, Paolo Pietro Bianchi, Davide Cavaliere, Leonardo Solaini, Claudio Coco, Gianluca Rizzo, Andrea Coratti, Raffaele De Luca, Michele Simone, Alberto Di Leo, Giovanni De Manzoni, Paola De Nardi, Ugo Elmore, Riccardo Rosati, Andrea Vignali, Paolo Delrio, Ugo Pace, Daniela Rega, Antonio Di Cataldo, Giovanni Li Destri, Annibale Donini, Luigina Graziosi, Andrea Fontana, Michela Mineccia, Sergio Gentilli, Manuela Monni, Mario Guerrieri, Monica Ortenzi, Francesca Pecchini, Micaela Piccoli, Italy. Corrado Pedrazzani, Giulia Turri, Sara Pollesel, Franco Roviello, Marco Rigamonti, Michele Zuolo, Mauro Santarelli, Federica Saraceno, Pierpaolo Sileri Giuseppe Sigismondo Sica, Luigi Siragusa Salvatore Pucciarelli, Matteo Zui

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE

    Search for New Physics with Jets and Missing Transverse Momentum in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for new physics is presented based on an event signature of at least three jets accompanied by large missing transverse momentum, using a data sample corresponding to an integrated luminosity of 36 inverse picobarns collected in proton--proton collisions at sqrt(s)=7 TeV with the CMS detector at the LHC. No excess of events is observed above the expected standard model backgrounds, which are all estimated from the data. Exclusion limits are presented for the constrained minimal supersymmetric extension of the standard model. Cross section limits are also presented using simplified models with new particles decaying to an undetected particle and one or two jets
    corecore