10 research outputs found

    Comparative assessment of “plaque/media” change on three modalities of IVUS immediately after implantation of either everolimus-eluting bioresorbable vascular scaffold or everolimus-eluting metallic stent in Absorb II study

    Get PDF
    The purpose of the study to assess the comparability of immediate changes in plaque/media volume (PV) on three modalities of intravascular ultrasound (IVUS) after implantation of either bioresorbable vascular scaffold (BVS) or everolimus-eluting metallic stent (EES) in Absorb II Study. The two devices have different device volume and ultrasound backscattering that may interfere with the "plaque/media" assessed by three modalities on IVUS: grayscale, backscattering of radiofrequency and brightness function. In a multicenter randomized controlled trial, 501 patients with stable or unstable angina underwent documentary IVUS pre- and post- implantation. The change in plaque/media volume (PV) was categorized into three groups according to the relative PV change in device segment: PV "increased" >+5% (PVI), PV unchanged ±5% (PVU), and PV decreased <-5% (PVD). The change in PV was re-evaluated three times: after subtraction of theoretical device volume, after analysis of echogenicity based on brightness function. In 449 patients, 483 lesions were analyzed pre- and post-implantation. "PVI" was more frequently observed in BVS (53.8%) than EES group (39.4%), p = 0.006. After subtraction of the theoretical device volume, the frequency of "PVI" decreased in both BVS (36.2%) and EES (32.1%) groups and became comparable (p = 0.581). In addition, the percentage of "PVI" was further reduced in both device groups after correction for either radiofrequency backscattering (BVS 34.4% vs. EES 22.6%) or echogenicity (BVS 25.2% vs. EES 9.7%). PV change in device segment was differently affected by BVS and EES devices implantation due to their differences in device volume and ultrasound backscattering. It implies that the lumen volume was also artifactually affected by the type of device implanted. Comparative IVUS assessment of lumen and plaque/media volume changes following implantation of BVS and EES requires specific methodological adjustmen

    Treatment with a dedicated bifurcation sirolimus-eluting cobalt-chromium stent for distal left main coronary artery disease : rationale and design of the POLBOS LM study

    No full text
    AIMS: The aim of this study is to demonstrate the non-inferiority of the BiOSS LIM C sirolimus-eluting cobalt-chromium bifurcation dedicated stent against the XIENCE stent regarding the patient-oriented composite endpoint (POCE) at 12 months among patients with left main coronary artery disease (LMCA). METHODS AND RESULTS: The POLBOS LM study is a single-arm, prospective, multicentre study enrolling 260 patients (SYNTAX score ≀32) with a pre-specified performance goal based on the results of the EXCEL trial with contemporary percutaneous coronary intervention (PCI) for LMCA disease. Patient enrolment will comply with objective inclusion criteria of diameter stenosis ≄50% in the LMCA based on off-line quantitative coronary angiography (QCA) analysed by an independent core laboratory using dedicated bifurcation QCA software. The BiOSS LIM C is used for the treatment of LMCA disease with the same specific technical classification as for the BiOSS LIM (modified MADS classification) and the stent implantation is optimised by using pre-specified intravascular ultrasound criteria. The primary endpoint is POCE (a composite of all-cause death, stroke, any myocardial infarction, and any revascularisation) at 12 months. CONCLUSIONS: The POLBOS LM study will indicate the efficacy of the BiOSS LIM C stent with contemporary PCI for distal left main bifurcation lesions in comparison with the XIENCE stent from the recent EXCEL trial, as a performance index

    The everolimus eluting Synergy MegatronTM drug-eluting stent platform:Early outcomes from the European Synergy MegatronTM Implanters' Registry

    Get PDF
    Background: The Synergy Megatron TM is an everolimus-drug eluting stent that may offer advantages in the treatment of aorto-ostial disease and large proximal vessels. Aims: To report the short- to medium-term clinical outcomes from the European Synergy Megatron TM Implanters' Registry. Methods: This registry was an investigator-initiated study conducted at 14 European centers. The primary outcome was target lesion failure (TLF), defined as the composite of cardiovascular death, target vessel myocardial infarction (MI), and target lesion revascularisation. Results: Five hundred seventy-five patients underwent PCI with Megatron TM between 2019 and 2021. Patients were 69 ± 12 years old, 26% had diabetes mellitus, 24% had moderate-severe left ventricular impairment and 59% presented with an acute coronary syndrome. 15% were deemed prohibitively high risk for surgical revascularisation. The target vessel involved the left main stem in 55%, the ostium of the RCA in 13% and was a true bifurcation (Medina 1,1,1) in 50%. At 1 year, TLF was observed in 40 patients, with 26 (65%) occurring within the first 30 days. The cumulative incidence of TLF was 4.5% at 30 days and 8.6% (95% CI 6.3–11.7) at 1 year. The incidence of stent thrombosis was 0.5% with no late stent thromboses. By multivariate analysis, the strongest independent predictors of TLF were severe left ventricular impairment (HR 3.43, 95% CI: 1.67–6.76, p &lt; 0.001) and a target vessel involving the left main (HR 4.00 95% CI 1.81–10.15 p = 0.001). Conclusions: Use of the Synergy Megatron TM everolimus eluting stent in a ‘real-world’ setting shows favorable outcomes at 30 days and 1 year.</p

    The ability of computed tomography angiography to predict 5-year mortality in the SYNTAX III REVOLUTION trial

    No full text
    Background The feasibility of using coronary computed tomography angiography (CCTA) for long-term prediction of vital prognosis post-revascularization remains unknown. Objectives To compare the prognostic value of the SYNTAX score II 2020 (SS-2020) derived from invasive coronary angiography (ICA) or CCTA in patients with three-vessel disease and/or left main coronary artery disease undergoing percutaneous or surgical revascularization. Methods In the SYNTAX III REVOLUTION trial, the probability of death at five years was retrospectively assessed by calculating the SS-2020 using ICA and CCTA. High- and low-risk patients for mortality were categorized according to the median percentages of predicted mortality based on both modalities. The discriminative abilities of the SS-2020 were assessed using Harrell's C statistic. Results The vital status at five years of the 215 patients revascularized percutaneously (64 patients, 29.8%) or surgically (151 patients, 70.2%) was established through national registries. In patients undergoing revascularization, the SS-2020 was possibly helpful in discriminating vital prognosis at 5 years, with similar results seen with ICA and CCTA (C-index with ICA ​= ​0.75, intercept ​= ​−0.19, slope ​= ​0.92 and C-index with CCTA ​= ​0.75, intercept ​= ​−0.22, slope ​= ​0.99). In high- and low-risk patients, Kaplan-Meier estimates showed significant, and almost identical relative differences in observed mortality, irrespective of imaging modality (ICA: 93.8% vs 78.7%, log-lank P ​< ​0.001; CCTA: 93.7% vs 78.5%, log-lank P ​< ​0.001). Conclusions The predictive ability of the SS-2020 for five-year all-cause mortality derived from ICA and CCTA was comparable, and could helpfully discriminate vital prognosis in high- and low-risk patients

    Temporal Trends in Transcatheter Aortic Valve Replacement in France

    No full text
    corecore