1,961 research outputs found

    A Proton Computed Tomography Demonstrator for Stopping Power Measurements

    Full text link
    Particle therapy is an established method to treat deep-seated tumours using accelerator-produced ion beams. For treatment planning, the precise knowledge of the relative stopping power (RSP) within the patient is vital. Conversion errors from x-ray computed tomography (CT) measurements to RSP introduce uncertainties in the applied dose distribution. Using a proton computed tomography (pCT) system to measure the SP directly could potentially increase the accuracy of treatment planning. A pCT demonstrator, consisting of double-sided silicon strip detectors (DSSD) as tracker and plastic scintillator slabs coupled to silicon photomultipliers (SiPM) as a range telescope, was developed. After a significant hardware upgrade of the range telescope, a 3D tomogram of an aluminium stair phantom was recorded at the MedAustron facility in Wiener Neustadt, Austria. In total, 80 projections with 6.5x10^5 primary events were acquired and used for the reconstruction of the RSP distribution in the phantom. After applying a straight-line approximation for the particle path inside the phantom, the most probable value (MPV) of the RSP distribution could be measured with an accuracy of 0.59%. The RSP resolution inside the phantom was only 9.3% due to a limited amount of projections and measured events per projection.Comment: Preprint submitted to the open-access Journal of Physics: Conference Series. (TIPP2021 conference proceedings). IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from i

    Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight

    Full text link
    For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray computed tomography (CT), which entails RSP inaccuracies due to conversion errors. A suitable method to improve the treatment plan accuracy is proton computed tomography (pCT). A typical pCT system consists of a tracking system and a separate residual energy (or range) detector to measure the RSP distribution directly. This paper introduces a novel pCT system based on a single detector technology, namely low gain avalanche detectors (LGADs). LGADs are fast 4D-tracking detectors, which can be used to simultaneously measure the particle position and time with precise timing and spatial resolution. In contrast to standard pCT systems, the residual energy is determined via a time-of-flight (TOF) measurement between different 4D-tracking stations. The design parameters for a realistic proton computed tomography system based on 4D-tracking detectors were studied and optimized using Monte Carlo simulations. The RSP accuracy and RSP resolution were measured inside the inserts of the CTP404 phantom to estimate the performance of the pCT system. After introducing a dedicated calibration procedure for the TOF calorimeter, RSP accuracies < 0.6 % could be achieved. Furthermore, the design parameters with the strongest impact on the RSP resolution were identified and a strategy to improve RSP resolution is proposed.Comment: Preprint submitted to Physics in Medicine and Biology. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from i

    Visual Blood, Visualisation of Blood Gas Analysis in Virtual Reality, Leads to More Correct Diagnoses: A Computer-Based, Multicentre, Simulation Study

    Get PDF
    Interpreting blood gas analysis results can be challenging for the clinician, especially in stressful situations under time pressure. To foster fast and correct interpretation of blood gas results, we developed Visual Blood. This computer-based, multicentre, noninferiority study compared Visual Blood and conventional arterial blood gas (ABG) printouts. We presented six scenarios to anaesthesiologists, once with Visual Blood and once with the conventional ABG printout. The primary outcome was ABG parameter perception. The secondary outcomes included correct clinical diagnoses, perceived diagnostic confidence, and perceived workload. To analyse the results, we used mixed models and matched odds ratios. Analysing 300 within-subject cases, we showed noninferiority of Visual Blood compared to ABG printouts concerning the rate of correctly perceived ABG parameters (rate ratio, 0.96; 95% CI, 0.92–1.00; p = 0.06). Additionally, the study revealed two times higher odds of making the correct clinical diagnosis using Visual Blood (OR, 2.16; 95% CI, 1.42–3.29; p < 0.001) than using ABG printouts. There was no or, respectively, weak evidence for a difference in diagnostic confidence (OR, 0.84; 95% CI, 0.58–1.21; p = 0.34) and perceived workload (Coefficient, 2.44; 95% CI, −0.09–4.98; p = 0.06). This study showed that participants did not perceive the ABG parameters better, but using Visual Blood resulted in more correct clinical diagnoses than using conventional ABG printouts. This suggests that Visual Blood allows for a higher level of situation awareness beyond individual parameters’ perception. However, the study also highlighted the limitations of today’s virtual reality headsets and Visual Blood

    Avatar-based patient monitoring improves information transfer, diagnostic confidence and reduces perceived workload in intensive care units: computer-based, multicentre comparison study

    Get PDF
    Patient monitoring is the foundation of intensive care medicine. High workload and information overload can impair situation awareness of staff, thus leading to loss of important information about patients’ conditions. To facilitate mental processing of patient monitoring data, we developed the Visual-Patient-avatar Intensive Care Unit (ICU), a virtual patient model animated from vital signs and patient installation data. It incorporates user-centred design principles to foster situation awareness. This study investigated the avatar’s effects on information transfer measured by performance, diagnostic confidence and perceived workload. This computer-based study compared Visual-Patient-avatar ICU and conventional monitor modality for the first time. We recruited 25 nurses and 25 physicians from five centres. The participants completed an equal number of scenarios in both modalities. Information transfer, as the primary outcome, was defined as correctly assessing vital signs and installations. Secondary outcomes included diagnostic confidence and perceived workload. For analysis, we used mixed models and matched odds ratios. Comparing 250 within-subject cases revealed that Visual-Patient-avatar ICU led to a higher rate of correctly assessed vital signs and installations [rate ratio (RR) 1.25; 95% CI 1.19–1.31; P < 0.001], strengthened diagnostic confidence [odds ratio (OR) 3.32; 95% CI 2.15–5.11, P < 0.001] and lowered perceived workload (coefficient − 7.62; 95% CI − 9.17 to − 6.07; P < 0.001) than conventional modality. Using Visual-Patient-avatar ICU, participants retrieved more information with higher diagnostic confidence and lower perceived workload compared to the current industry standard monitor

    User Perceptions of Avatar-Based Patient Monitoring for Intensive Care Units: An International Exploratory Sequential Mixed-Methods Study

    Get PDF
    Visual Patient Avatar ICU is an innovative approach to patient monitoring, enhancing the user’s situation awareness in intensive care settings. It dynamically displays the patient’s current vital signs using changes in color, shape, and animation. The technology can also indicate patient-inserted devices, such as arterial lines, central lines, and urinary catheters, along with their insertion locations. We conducted an international, multi-center study using a sequential qualitative-quantitative design to evaluate users’ perception of Visual Patient Avatar ICU among physicians and nurses. Twenty-five nurses and twenty-five physicians from the ICU participated in the structured interviews. Forty of them completed the online survey. Overall, ICU professionals expressed a positive outlook on Visual Patient Avatar ICU. They described Visual Patient Avatar ICU as a simple and intuitive tool that improved information retention and facilitated problem identification. However, a subset of participants expressed concerns about potential information overload and a sense of incompleteness due to missing exact numerical values. These findings provide valuable insights into user perceptions of Visual Patient Avatar ICU and encourage further technology development before clinical implementation

    User Perceptions of Visual Blood: An International Mixed Methods Study on Novel Blood Gas Analysis Visualization

    Get PDF
    Blood gas analysis plays a central role in modern medicine. Advances in technology have expanded the range of available parameters and increased the complexity of their interpretation. By applying user-centered design principles, it is possible to reduce the cognitive load associated with interpreting blood gas analysis. In this international, multicenter study, we explored anesthesiologists’ perspectives on Visual Blood, a novel visualization technique for presenting blood gas analysis results. We conducted interviews with participants following two computer-based simulation studies, the first utilizing virtual reality (VR) (50 participants) and the second without VR (70 participants). Employing the template approach, we identified key themes in the interview responses and formulated six statements, which were rated using Likert scales from 1 (strongly disagree) to 5 (strongly agree) in an online questionnaire. The most frequently mentioned theme was the positive usability features of Visual Blood. The online survey revealed that participants found Visual Blood to be an intuitive method for interpreting blood gas analysis (median 4, interquartile range (IQR) 4-4, p < 0.001). Participants noted that minimal training was required to effectively learn how to interpret Visual Blood (median 4, IQR 4-4, p < 0.001). However, adjustments are necessary to reduce visual overload (median 4, IQR 2-4, p < 0.001). Overall, Visual Blood received a favorable response. The strengths and weaknesses derived from these data will help optimize future versions of Visual Blood to improve the presentation of blood gas analysis results

    Prevalence of human papillomavirus infection of the anal canal in women: A prospective analysis of high-risk populations

    Get PDF
    Infection with certain types of human papillomavirus (HPV) has been associated with the development of cervical and anal cancer. Worldwide, the incidence of anal cancer has increased markedly. The present study aimed to evaluate the prevalence of HPV infection of the uterine cervix and anal canal in human immunodeficiency virus (HIV)- and non-HIV-infected risk populations. Cervical and anal HPV swabs and cytology samples were collected from 287 patients at the University Hospital of Munich, Germany between 2011 and 2013. Patients were divided into HIV-negative controls (G1) and two risk groups, including HIV-negative patients with cytological abnormalities of the cervix (G2) and HIV-infected patients (G3). Data, including clinical parameters, were analysed. The risk groups had significantly more positive results for HPV in the anus (71.03 and 83.15% for G2 and G3, respectively), as compared with G1. The predominant HPV genotypes found in the anus were high-risk HPV genotypes, which were significantly correlated with concomittant cervical HPV findings. In the risk groups, a significant association between the cytological findings and HPV detection in the cervix was found, while the results of the anus revealed no significance. The results of the present study suggested that the prevalence of HPV infection in the anal canal of risk populations is high. Furthermore, patients with abnormal cervical cytology results and HIV-infected women, irrespective of their individual cervical findings, may have a risk of concomittant anal high-risk HPV infection. Based on the predominant HPV genotypes found in the study, HPV vaccination could reduce the incidence of anal cancer. Nevertheless, high-risk patients should be intensively screened for anal squamous intraepithelial abnormalities to avoid invasive cancer stages

    Is lymphadenectomy a prognostic marker in endometrioid adenocarcinoma of the human endometrium?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>During surgery for endometrial cancer, a pelvic lymphadenectomy with or without para-aortic lymphadenectomy is performed at least in patients with risk factors (stage I, grading 2 and/or histological subtypes with higher risk of lymphatic spread), and is hence recommended by the International Federation of Obstetrics and Gynecology (FIGO). Although lymph node metastases are important prognostic parameters, it has been contentious whether a pelvic lymph node dissection itself has a prognostic impact in the treatment of endometrial cancer, especially in endometrioid adenocarcinoma. Therefore, this study evaluated whether lymphadenectomy has a prognostic impact in patients with endometrioid adenocarcinoma.</p> <p>Methods</p> <p>The benefits of lymphadenectomy were examined in 214 patients with a histological diagnosis of endometrial adenocarcinoma. Tumour characteristics were analysed with respect to the surgical and pathological stage.</p> <p>Results</p> <p>Of the 214 patients with endometrial adenocarcinoma, 171 (79.9%) were classified as FIGO stage I, 15 (7.0%) FIGO stage II, 21 (9.8%) FIGO stage III and 7 (3.3%) FIGO stage IV. One hundred and thirty four (62.6%) of the patients had a histological grade 1 tumour, while 56 (26.2%) and 24 (11.2%) had a histological grade 2 or grade 3 tumour, respectively. Lymphadenectomy was performed in 151 (70.6%) patients. Only 11 (5.1%) patients showed metastatic disease in the lymph nodes. The performance of a lymphadenectomy resulted in significantly increased cause-specific and overall survival, while progression-free survival was not affected by this operative procedure.</p> <p>Conclusions</p> <p>The performance of an operative lymphadenectomy resulted in better survival of patients with endometrioid adenocarcinoma. This increase was significant for cause-specific and overall survival, while there was a tendency only towards increased progression-free survival. Therefore, even in endometrioid adenocarcinoma, a pelvic and/or para-aortic lymphadenectomy should be performed.</p

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE

    Search for the standard model Higgs boson decaying into two photons in pp collisions at sqrt(s)=7 TeV

    Get PDF
    A search for a Higgs boson decaying into two photons is described. The analysis is performed using a dataset recorded by the CMS experiment at the LHC from pp collisions at a centre-of-mass energy of 7 TeV, which corresponds to an integrated luminosity of 4.8 inverse femtobarns. Limits are set on the cross section of the standard model Higgs boson decaying to two photons. The expected exclusion limit at 95% confidence level is between 1.4 and 2.4 times the standard model cross section in the mass range between 110 and 150 GeV. The analysis of the data excludes, at 95% confidence level, the standard model Higgs boson decaying into two photons in the mass range 128 to 132 GeV. The largest excess of events above the expected standard model background is observed for a Higgs boson mass hypothesis of 124 GeV with a local significance of 3.1 sigma. The global significance of observing an excess with a local significance greater than 3.1 sigma anywhere in the search range 110-150 GeV is estimated to be 1.8 sigma. More data are required to ascertain the origin of this excess.Comment: Submitted to Physics Letters
    corecore