6 research outputs found

    Calidad de las compresiones torácicas en resucitación cardiopulmonar practicada en condiciones extremas de temperatura ambiental

    Get PDF
    Under the care of a team of health professionals in an out-of-hospital cardiorespiratory arrest (PCREH), they can be found in conditions in extreme conditions of ambient temperature, depending on the area where they are located, the time of the year, and even the time of day.Objective: The objective of this study was to verify whether the efficacy of Cardiopulmonary Resuscitation (CPR) was affected by extreme heat (40ºC) and cold (0ºC) temperature environments, compared to a CPR in ambient temperature (22ºC).Method: 2 minutes of uninterrupted external chest compressions (ECC) were performed under ambient temperature conditions of 40ºC, 0ºC and 22ºC, in a realistic mannequin Resusci Anne QCPR with SIMPAD.Results: 30 participants, both people with prior training in CPR (86.7%) and without it (13.3%), were part of the sample, 26 women (86.7%) and 4 men (13.3%), with a mean age of 27.37 ± 8.88 years. No statistically significant differences were found in the efficacy of CPR; but there were differences between the total number of CT (p = 0.042), the average depth of the ECC (p = 0.015) and the average frequency (p = 0.034). The Borg scale of perceived exertion (RPE) showed an average of 4.4 ± 1.303 at 22° C, 4.97 ± 1.402 at 40° C and 4.87 ± 2.08 at 0° C (p> 0.05). There were no significant differences in hair lactate.Conclusions: It is concluded that there are no significant differences between the three conditions, although it seems that the cold and room temperatures resemble results and that the heat temperature offers a slight disadvantage of the others.En la atención del equipo de profesionales de la salud en una parada cardiorrespiratoria extrahospitalaria (PCREH), se pueden encontrar en condiciones extremas de temperatura ambiental, según la zona donde se encuentren, la época del año, e incluso la franja horaria. Objetivo: El objetivo de este trabajo fue comprobar si la eficacia de la Reanimación Cardiopulmonar (RCP) se veía afectada en ambientes de temperatura calor (40ºC) y frío (0ºC) extremos, en comparación con una RCP en temperatura ambiental (22ºC).Método: Se realizaron 2 minutos de compresiones torácicas (CT) ininterrumpidas en las condiciones de temperatura de 40ºC, 0ºC y 22ºC, en un maniquí realista Resusci Anne QCPR con SIMPAD. Resultados: 30 participantes, tanto con formación previa en RCP (86,7%) o sin ella (13,3%), formaron parte de la muestra, 26 mujeres (86,7%) y 4 hombres (13,3%), con una media de edad de 27,37±8,88 años. No se encontraron diferencias estadísticamente significativas en la eficacia de la RCP; pero sí que hubo diferencias entre el número total de CT (p=0,042), la profundidad media de las CT (p=0,015) y en la frecuencia media (p=0,034). La escala de Borg de esfuerzo percibido (RPE) mostró una media de 4,4±1,303 a 22ºC, 4,97±1,402 a 40ºC y 4,87±2,08 a 0ºC (p>0,05). No hubo diferencias significativas en el lactato capilar.Conclusiones: Se concluye que no existen diferencias significativas entre las tres condiciones, aunque parece que la temperatura ambiental y la fría se asemejan en los resultados y la temperatura calor ofrece una ligera desventaja al respecto

    Cuidados de enfermería al paciente con disfonía espasmódica o distonía laríngea

    Get PDF
    Introducción/justificación: La disfonía espasmódica (DE) es una enfermedad rara que se caracteriza por movimientos espasmódicos de las cuerdas vocales. Se trata de un trastorno de difícil diagnóstico y cuyo tratamiento sólo mejora temporalmente los síntomas. Constituye un proceso complicado en el que se producen repercusiones sobre todo a nivel psicológico y social. En consecuencia, la función de enfermería plantea un papel decisivo en la mejora del afrontamiento, la estabilización emocional y la readaptación con el entorno. El presente Trabajo de Fin de Grado consta de un Plan de Cuidados Enfermero a una paciente recientemente diagnosticada de disfonía espasmódica de larga evolución.Objetivos: Determinar un Plan de Cuidados orientado a proporcionar ayuda y apoyo psicosocial a un paciente de DE, a través del diseño e implantación de un Proceso de Atención de Enfermería, en el área de Atención Primaria.Metodología: Trabajo basado en una revisión bibliográfica en distintas fuentes de información como bases de datos, asociaciones, uso de escalas de valoración, todo ello realizado mediante la metodología científica enfermera. Se realiza un Plan de Cuidados comenzando con una valoración integral siguiendo los Patrones Funcionales de salud de Marjory Gordon, para posteriormente nombrar los diagnósticos enfermeros, objetivos e intervenciones con la taxonomía enfermera NANDA, NOC, NIC.Conclusión:. Tras la realización de las actividades programadas, se podrá conseguir los objetivos planteados en nuestro plan de cuidados, centrándose estos en la formación al paciente y su entorno, el apoyo psicosocial, el afrontamiento de la enfermedad con el fin de recuperar el bienestar del paciente.<br /

    Quality of chest compressions in cardiopulmonary resuscitation performed in extreme ambient temperature conditions

    No full text
    En la atención del equipo de profesionales de la salud en una parada cardiorrespiratoria extrahospitalaria (PCREH), se pueden encontrar en condiciones extremas de temperatura ambiental, según la zona donde se encuentren, la época del año, e incluso la franja horaria. Objetivo: El objetivo de este trabajo fue comprobar si la eficacia de la Reanimación Cardiopulmonar (RCP) se veía afectada en ambientes de temperatura calor (40ºC) y frío (0ºC) extremos, en comparación con una RCP en temperatura ambiental (22ºC). Método: Se realizaron 2 minutos de compresiones torácicas (CT) ininterrumpidas en las condiciones de temperatura de 40ºC, 0ºC y 22ºC, en un maniquí realista Resusci Anne QCPR con SIMPAD. Resultados: 30 participantes, tanto con formación previa en RCP (86,7%) o sin ella (13,3%), formaron parte de la muestra, 26 mujeres (86,7%) y 4 hombres (13,3%), con una media de edad de 27,37±8,88 años. No se encontraron diferencias estadísticamente significativas en la eficacia de la RCP; pero sí que hubo diferencias entre el número total de CT (p=0,042), la profundidad media de las CT (p=0,015) y en la frecuencia media (p=0,034). La escala de Borg de esfuerzo percibido (RPE) mostró una media de 4,4±1,303 a 22ºC, 4,97±1,402 a 40ºC y 4,87±2,08 a 0ºC (p>0,05). No hubo diferencias significativas en el lactato capilar. Conclusiones: Se concluye que no existen diferencias significativas entre las tres condiciones, aunque parece que la temperatura ambiental y la fría se asemejan en los resultados y la temperatura calor ofrece una ligera desventaja al respecto.Under the care of a team of health professionals in an out-of-hospital cardiorespiratory arrest (PCREH), they can be found in conditions in extreme conditions of ambient temperature, depending on the area where they are located, the time of the year, and even the time of day. Objective: The objective of this study was to verify whether the efficacy of Cardiopulmonary Resuscitation (CPR) was affected by extreme heat (40ºC) and cold (0ºC) temperature environments, compared to a CPR in ambient temperature (22ºC). Method: 2 minutes of uninterrupted external chest compressions (ECC) were performed under ambient temperature conditions of 40ºC, 0ºC and 22ºC, in a realistic mannequin Resusci Anne QCPR with SIMPAD. Results: 30 participants, both people with prior training in CPR (86.7%) and without it (13.3%), were part of the sample, 26 women (86.7%) and 4 men (13.3%), with a mean age of 27.37 ± 8.88 years. No statistically significant differences were found in the efficacy of CPR; but there were differences between the total number of CT (p = 0.042), the average depth of the ECC (p = 0.015) and the average frequency (p = 0.034). The Borg scale of perceived exertion (RPE) showed an average of 4.4 ± 1.303 at 22° C, 4.97 ± 1.402 at 40° C and 4.87 ± 2.08 at 0° C (p> 0.05). There were no significant differences in hair lactate. Conclusions: It is concluded that there are no significant differences between the three conditions, although it seems that the cold and room temperatures resemble results and that the heat temperature offers a slight disadvantage of the others

    Measurements of the pp -> ZZ production cross section and the Z -> 4l branching fraction, and constraints on anomalous triple gauge couplings at root s=13TeV

    Get PDF
    Correction: DOI:10.1140/epjc/s10052-018-5769-1Four-lepton production in proton-proton collisions, pp -> (Z/gamma*)(Z/gamma*) -> 4l, where l = e or mu, is studied at a center-of-mass energy of 13 TeV with the CMS detector at the LHC. The data sample corresponds to an integrated luminosity of 35.9 fb(-1). The ZZ production cross section, sigma(pp -> ZZ) = 17.2 +/- 0.5 (stat) +/- 0.7 (syst) +/- 0.4 (theo) +/- 0.4 (lumi) pb, measured using events with two opposite-sign, same-flavor lepton pairs produced in the mass region 60 4l) = 4.83(-0.22)(+0.23) (stat)(-0.29)(+0.32) (syst) +/- 0.08 (theo) +/- 0.12(lumi) x 10(-6) for events with a four-lepton invariant mass in the range 80 4GeV for all opposite-sign, same-flavor lepton pairs. The results agree with standard model predictions. The invariant mass distribution of the four-lepton system is used to set limits on anomalous ZZZ and ZZ. couplings at 95% confidence level: -0.0012 <f(4)(Z) <0.0010, -0.0010 <f(5)(Z) <0.0013, -0.0012 <f(4)(gamma) <0.0013, -0.0012 <f(5)(gamma) <0.0013.Peer reviewe

    Erratum to: Measurements of the ppZZpp \to ZZ production cross section and the Z4Z \to 4 \ell branching fraction, and constraints on anomalous triple gauge couplings at s=\sqrt{s} = 13 TeV

    No full text
    Four-lepton production in proton-proton collisions, pp(Z/γ)(Z/γ)4\mathrm {p}\mathrm {p}\rightarrow (\mathrm{Z}/ \gamma ^*)(\mathrm{Z}/\gamma ^*) \rightarrow 4\ell , where =e\ell = \mathrm {e} or μ\mu , is studied at a center-of-mass energy of 13 TeV\,\text {TeV} with the CMS detector at the LHC. The data sample corresponds to an integrated luminosity of 35.9 fb1\,\text {fb}^{-1} . The ZZ production cross section, σ(ppZZ)=17.2±0.5(stat)±0.7(syst)±0.4(theo)±0.4(lumi) pb\sigma (\mathrm {p}\mathrm {p}\rightarrow \mathrm{Z}\mathrm{Z}) = 17.2 \pm 0.5\,\text {(stat)} \pm 0.7\,\text {(syst)} \pm 0.4\,\text {(theo)} \pm 0.4\,\text {(lumi)} \text { pb} , measured using events with two opposite-sign, same-flavor lepton pairs produced in the mass region 604GeV60 4\,\text {GeV} for all opposite-sign, same-flavor lepton pairs. The results agree with standard model predictions. The invariant mass distribution of the four-lepton system is used to set limits on anomalous ZZZ and ZZ γ\gamma couplings at 95% confidence level: 0.0012<f4Z<0.0010-0.0012<f_4^\mathrm{Z}<0.0010 , 0.0010<f5Z<0.0013-0.0010<f_5^\mathrm{Z}<0.0013 , 0.0012<f4γ<0.0013-0.0012<f_4^{\gamma }<0.0013 , 0.0012<f5γ<0.0013-0.0012<f_5^{\gamma }< 0.0013

    Measurements of the pp\toZZ production cross section and the Z4\to 4\ell branching fraction, and constraints on anomalous triple gauge couplings at s=\sqrt{s} = 13 TeV

    No full text
    Four-lepton production in proton-proton collisions, pp(Z/γ)(Z/γ)4\mathrm{pp}\to (\mathrm{Z}/ \gamma^*)(\mathrm{Z}/\gamma^*) \to 4\ell, where =e\ell = \mathrm{e} or μ\mu, is studied at a center-of-mass energy of 13 TeV with the CMS detector at the LHC. The data sample corresponds to an integrated luminosity of 35.9 fb1^{-1}. The ZZ production cross section, σ(ppZZ)=17.2±0.5 (stat) ±0.7 (syst) ±0.4(theo)±0.4 (lum)\sigma(\mathrm{pp} \to \mathrm{Z}\mathrm{Z}) = 17.2 \pm 0.5\text{ (stat) }\pm 0.7\text{ (syst) }\pm 0.4(\mathrm{theo}) \pm 0.4\text{ (lum)} pb, measured using events with two opposite-sign, same-flavor lepton pairs produced in the mass region 6060 4 GeV for all opposite-sign, same-flavor lepton pairs. The results agree with standard model predictions. The invariant mass distribution of the four-lepton system is used to set limits on anomalous ZZZ and ZZγ\gamma couplings at 95% confidence level: 0.0012<f4Z<0.0010-0.0012<f_4^\mathrm{Z}<0.0010, 0.0010<f5Z<0.0013-0.0010<f_5^\mathrm{Z}<0.0013, 0.0012<f4γ<0.0013-0.0012<f_4^{\gamma}<0.0013, 0.0012<f5γ<0.0013-0.0012<f_5^{\gamma}< 0.0013
    corecore