262 research outputs found
Characterization of systematic error in Advanced LIGO calibration
The raw outputs of the detectors within the Advanced Laser Interferometer
Gravitational-Wave Observatory need to be calibrated in order to produce the
estimate of the dimensionless strain used for astrophysical analyses. The two
detectors have been upgraded since the second observing run and finished the
year-long third observing run. Understanding, accounting, and/or compensating
for the complex-valued response of each part of the upgraded detectors improves
the overall accuracy of the estimated detector response to gravitational waves.
We describe improved understanding and methods used to quantify the response of
each detector, with a dedicated effort to define all places where systematic
error plays a role. We use the detectors as they stand in the first half (six
months) of the third observing run to demonstrate how each identified
systematic error impacts the estimated strain and constrain the statistical
uncertainty therein. For this time period, we estimate the upper limit on
systematic error and associated uncertainty to be in magnitude and deg in phase ( confidence interval) in the most sensitive frequency
band 20-2000 Hz. The systematic error alone is estimated at levels of
in magnitude and deg in phase
Point absorbers in Advanced LIGO
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nanometer scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduce the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback control system. We review the expected surface deformation from point absorbers and provide a pedagogical description of the impact on power buildup in second generation gravitational wave detectors (dual-recycled Fabry–Perot Michelson interferometers). This analysis predicts that the power-dependent reduction in interferometer performance will significantly degrade maximum stored power by up to 50% and, hence, limit GW sensitivity, but it suggests system wide corrections that can be implemented in current and future GW detectors. This is particularly pressing given that future GW detectors call for an order of magnitude more stored power than currently used in Advanced LIGO in Observing Run 3. We briefly review strategies to mitigate the effects of point absorbers in current and future GW wave detectors to maximize the success of these enterprises
Sensitivity and performance of the Advanced LIGO detectors in the third observing run
On April 1st, 2019, the Advanced Laser Interferometer Gravitational-Wave Observatory (aLIGO), joined by the Advanced Virgo detector, began the third observing run, a year-long dedicated search for gravitational radiation. The LIGO detectors have achieved a higher duty cycle and greater sensitivity to gravitational waves than ever before, with LIGO Hanford achieving angle-averaged sensitivity to binary neutron star coalescences to a distance of 111 Mpc, and LIGO Livingston to 134 Mpc with duty factors of 74.6% and 77.0% respectively. The improvement in sensitivity and stability is a result of several upgrades to the detectors, including doubled intracavity power, the addition of an in-vacuum optical parametric oscillator for squeezed-light injection, replacement of core optics and end reaction masses, and installation of acoustic mode dampers. This paper explores the purposes behind these upgrades, and explains to the best of our knowledge the noise currently limiting the sensitivity of each detector
Quantum-enhanced advanced LIGO detectors in the era of gravitational-wave astronomy
The Laser Interferometer Gravitational Wave Observatory (LIGO) has been directly detecting gravitational waves from compact binary mergers since 2015. We report on the first use of squeezed vacuum states in the direct measurement of gravitational waves with the Advanced LIGO H1 and L1 detectors. This achievement is the culmination of decades of research to implement squeezed states in gravitational-wave detectors. During the ongoing O3 observation run, squeezed states are improving the sensitivity of the LIGO interferometers to signals above 50 Hz by up to 3 dB, thereby increasing the expected detection rate by 40% (H1) and 50% (L1)
Sensitivity and Performance of the Advanced LIGO Detectors in the Third Observing Run
On April 1st, 2019, the Advanced Laser Interferometer Gravitational-Wave
Observatory (aLIGO), joined by the Advanced Virgo detector, began the third
observing run, a year-long dedicated search for gravitational radiation. The
LIGO detectors have achieved a higher duty cycle and greater sensitivity to
gravitational waves than ever before, with LIGO Hanford achieving
angle-averaged sensitivity to binary neutron star coalescences to a distance of
111 Mpc, and LIGO Livingston to 134 Mpc with duty factors of 74.6% and 77.0%
respectively. The improvement in sensitivity and stability is a result of
several upgrades to the detectors, including doubled intracavity power, the
addition of an in-vacuum optical parametric oscillator for squeezed-light
injection, replacement of core optics and end reaction masses, and installation
of acoustic mode dampers. This paper explores the purposes behind these
upgrades, and explains to the best of our knowledge the noise currently
limiting the sensitivity of each detector.Comment: 27 pages, 11 figures. v2 edits: minor wording changes, author
additions, and grayscale-friendly figure
Quantum correlations between light and the kilogram-mass mirrors of LIGO
The measurement of minuscule forces and displacements with ever greater precision is inhibited by the Heisenberg uncertainty principle, which imposes a limit to the precision with which the position of an object can be measured continuously, known as the standard quantum limit. When light is used as the probe, the standard quantum limit arises from the balance between the uncertainties of the photon radiation pressure applied to the object and of the photon number in the photoelectric detection. The only way to surpass the standard quantum limit is by introducing correlations between the position/momentum uncertainty of the object and the photon number/phase uncertainty of the light that it reflects. Here we confirm experimentally the theoretical prediction that this type of quantum correlation is naturally produced in the Laser Interferometer Gravitational-wave Observatory (LIGO). We characterize and compare noise spectra taken without squeezing and with squeezed vacuum states injected at varying quadrature angles. After subtracting classical noise, our measurements show that the quantum mechanical uncertainties in the phases of the 200-kilowatt laser beams and in the positions of the 40-kilogram mirrors of the Advanced LIGO detectors yield a joint quantum uncertainty that is a factor of 1.4 (3 decibels) below the standard quantum limit. We anticipate that the use of quantum correlations will improve not only the observation of gravitational waves, but also more broadly future quantum noise-limited measurements
Environmental Noise in Advanced LIGO Detectors
The sensitivity of the Advanced LIGO detectors to gravitational waves can be
affected by environmental disturbances external to the detectors themselves.
Since the transition from the former initial LIGO phase, many improvements have
been made to the equipment and techniques used to investigate these
environmental effects. These methods have aided in tracking down and mitigating
noise sources throughout the first three observing runs of the advanced
detector era, keeping the ambient contribution of environmental noise below the
background noise levels of the detectors. In this paper we describe the methods
used and how they have led to the mitigation of noise sources, the role that
environmental monitoring has played in the validation of gravitational wave
events, and plans for future observing runs
First measurement of the Hubble Constant from a Dark Standard Siren using the Dark Energy Survey Galaxies and the LIGO/Virgo Binary–Black-hole Merger GW170814
International audienceWe present a multi-messenger measurement of the Hubble constant H 0 using the binary–black-hole merger GW170814 as a standard siren, combined with a photometric redshift catalog from the Dark Energy Survey (DES). The luminosity distance is obtained from the gravitational wave signal detected by the Laser Interferometer Gravitational-Wave Observatory (LIGO)/Virgo Collaboration (LVC) on 2017 August 14, and the redshift information is provided by the DES Year 3 data. Black hole mergers such as GW170814 are expected to lack bright electromagnetic emission to uniquely identify their host galaxies and build an object-by-object Hubble diagram. However, they are suitable for a statistical measurement, provided that a galaxy catalog of adequate depth and redshift completion is available. Here we present the first Hubble parameter measurement using a black hole merger. Our analysis results in , which is consistent with both SN Ia and cosmic microwave background measurements of the Hubble constant. The quoted 68% credible region comprises 60% of the uniform prior range [20, 140] km s−1 Mpc−1, and it depends on the assumed prior range. If we take a broader prior of [10, 220] km s−1 Mpc−1, we find (57% of the prior range). Although a weak constraint on the Hubble constant from a single event is expected using the dark siren method, a multifold increase in the LVC event rate is anticipated in the coming years and combinations of many sirens will lead to improved constraints on H 0
- …