251 research outputs found

    Alcohol Intake and Blood Pressure Levels: A Dose-Response Meta-Analysis of Nonexperimental Cohort Studies

    Get PDF
    Background: Alcohol consumption may increase blood pressure but the details of the relationship are incomplete, particularly for the association at low levels of alcohol consumption, and no meta-analyses are available for nonexperimental cohort studies. Methods: We performed a systematic search of longitudinal studies in healthy adults that reported on the association between alcohol intake and blood pressure. Our end points were the mean differences over time of systolic (SBP) and diastolic blood pressure (DBP), plotted according to baseline alcohol intake, by using a dose-response 1-stage meta-analytic methodology. Results: Seven studies, with 19 548 participants and a median follow-up of 5.3 years (range, 4-12 years), were included in the analysis. We observed a substantially linear positive association between baseline alcohol intake and changes over time in SBP and DBP, with no suggestion of an exposure-effect threshold. Overall, average SBP was 1.25 and 4.90 mm Hg higher for 12 or 48 grams of daily alcohol consumption, compared with no consumption. The corresponding differences for DBP were 1.14 and 3.10 mm Hg. Subgroup analyses by sex showed an almost linear association between baseline alcohol intake and SBP changes in both men and women, and for DBP in men while in women we identified an inverted U-shaped association. Alcohol consumption was positively associated with blood pressure changes in both Asians and North Americans, apart from DBP in the latter group. Conclusions: Our results suggest the association between alcohol consumption and SBP is direct and linear with no evidence of a threshold for the association, while for DBP the association is modified by sex and geographic location

    Who approves/pays for additional monitoring?

    Get PDF
    Major considerations in the provision of healthcare are availability, affordability, accessibility, and appropriateness, especially in the setting of heart failure where disease burden is growing, developments have been rapid and newer biomarkers, diagnostic and imaging techniques, monitoring systems, devices, procedures, and drugs have all been developed in a relatively short period of time. Many monitoring and diagnostic systems have been developed but the disproportionate cost of conducting trials of their effectiveness has limited their uptake. There are added complexities, in that the utilization of doctors for the supervision of the monitoring results may be optimal in one setting and not in another because of differences in the characteristics of organization of healthcare provision, making even interpretation of the trials we have had, still difficult to interpret. New technologies are continuously changing the approach to healthcare and will reshape the structure of the healthcare systems in the future. Mobile technologies can empower patients and carers by giving them more control over their health and social care needs and reducing their dependence on healthcare professionals for monitoring their health, but a significant problem is the integration of the multitude of monitored parameters with clinical data and the recognition of intervention thresholds. Digital technology can help, but we need to prove its cost/efficacy and how it will be paid for. Governments in many European countries and worldwide are trying to establish frameworks that promote the convergence of standards and regulations for telemedicine solutions and yet simultaneously health authorities are closely scrutinizing healthcare spending, with the objective of reducing and optimizing expenditure in the provision of health services. There are multiple factors to be considered for the reimbursement models associated with the implementation of physiological monitoring yet it remains a challenge in cash-strapped health systems

    REducing INFectiOns thRough Cardiac device Envelope: insight from real world data. The REINFORCE Project

    Get PDF
    Background: Infections resulting from cardiac implantable electronic device (CIED) implantation are severely impacting on patients' and on health care systems. The use of TYRXTM absorbable antibiotic-eluting envelope has proven to decrease major CIED infections within 12 months of CIED surgery. Aims: to evaluate the impact of the envelope use on infection-related clinical events in a real-world contemporary patient population. Methods: Data on patients undergoing CIED surgery were collected prospectively by participating centers of the One Hospital ClinicalService project. Patients were divided into two groups according to whether TYRXTM absorbable antibiotic-eluting envelope was used or not. Results: Out of 1819 patients, 872 (47.9%) were implanted with an absorbable antibiotic-eluting envelope and included in the Envelope group and 947 (52.1%) patients who did not receive an envelope were included in the Control group. Compared to control, patients in the Envelope group had higher thrombo-embolic or hemorrhagic risk, higher BMI, lower LVEF and more comorbidities. During a mean follow-up of 1.4 years, the incidence of infection-related events was significantly higher in the control compared to the Envelope group (2.4% vs 0.8%, p = 0.007). The 5-year cumulative incidence of infection-related events was 8.1% in the control and 2.1% in the Envelope group (HR: 0.34, 95%CI: 0.14-0.80, p = 0.010). Conclusions: In our analysis, the use of an absorbable antibiotic-eluting envelope in the general CIED population was associated with a lower risk of systemic and pocket infection

    Effects of remote monitoring on clinical outcomes and use of healthcare resources in heart failure patients with biventricular defibrillators: results of the MORE-CARE multicentre randomized controlled trial

    Get PDF
    Aims: The aim of this study was to evaluate the clinical efficacy and safety of remote monitoring in patients with heart failure implanted with a biventricular defibrillator (CRT-D) with advanced diagnostics. Methods and results: The MORE-CARE trial is an international, prospective, multicentre, randomized controlled trial. Within 8 weeks of de novo implant of a CRT-D, patients were randomized to undergo remote checks alternating with in-office follow-ups (Remote arm) or in-office follow-ups alone (Standard arm). The primary endpoint was a composite of death and cardiovascular (CV) and device-related hospitalization. Use of healthcare resources was also evaluated. A total of 865 eligible patients (mean age 66 \ub1 10 years) were included in the final analysis (437 in the Remote arm and 428 in the Standard arm) and followed for a median of 24 (interquartile range = 15\u201326) months. No significant difference was found in the primary endpoint between the Remote and Standard arms [hazard ratio 1.02, 95% confidence interval (CI) 0.80\u20131.30, P = 0.89] or in the individual components of the primary endpoint (P > 0.05). For the composite endpoint of healthcare resource utilization (i.e. 2-year rates of CV hospitalizations, CV emergency department admissions, and CV in-office follow-ups), a significant 38% reduction was found in the Remote vs. Standard arm (incidence rate ratio 0.62, 95% CI 0.58\u20130.66, P < 0.001) mainly driven by a reduction of in-office visits. Conclusions: In heart failure patients implanted with a CRT-D, remote monitoring did not reduce mortality or risk of CV or device-related hospitalization. Use of healthcare resources was significantly reduced as a result of a marked reduction of in-office visits without compromising patient safety. Trial registration: NCT00885677

    U and Th content in the Central Apennines continental crust: a contribution to the determination of the geo-neutrinos flux at LNGS

    Full text link
    The regional contribution to the geo-neutrino signal at Gran Sasso National Laboratory (LNGS) was determined based on a detailed geological, geochemical and geophysical study of the region. U and Th abundances of more than 50 samples representative of the main lithotypes belonging to the Mesozoic and Cenozoic sedimentary cover were analyzed. Sedimentary rocks were grouped into four main "Reservoirs" based on similar paleogeographic conditions and mineralogy. Basement rocks do not outcrop in the area. Thus U and Th in the Upper and Lower Crust of Valsugana and Ivrea-Verbano areas were analyzed. Based on geological and geophysical properties, relative abundances of the various reservoirs were calculated and used to obtain the weighted U and Th abundances for each of the three geological layers (Sedimentary Cover, Upper and Lower Crust). Using the available seismic profile as well as the stratigraphic records from a number of exploration wells, a 3D modelling was developed over an area of 2^{\circ}x2^{\circ} down to the Moho depth, for a total volume of about 1.2x10^6 km^3. This model allowed us to determine the volume of the various geological layers and eventually integrate the Th and U contents of the whole crust beneath LNGS. On this base the local contribution to the geo-neutrino flux (S) was calculated and added to the contribution given by the rest of the world, yielding a Refined Reference Model prediction for the geo-neutrino signal in the Borexino detector at LNGS: S(U) = (28.7 \pm 3.9) TNU and S(Th) = (7.5 \pm 1.0) TNU. An excess over the total flux of about 4 TNU was previously obtained by Mantovani et al. (2004) who calculated, based on general worldwide assumptions, a signal of 40.5 TNU. The considerable thickness of the sedimentary rocks, almost predominantly represented by U- and Th- poor carbonatic rocks in the area near LNGS, is responsible for this difference.Comment: 45 pages, 5 figures, 12 tables; accepted for publication in GC

    Antiarrhythmic Effect of Reverse Ventricular Remodeling Induced by Cardiac Resynchronization Therapy The InSync ICD (Implantable Cardioverter-Defibrillator) Italian Registry

    Get PDF
    Objectives: We investigated whether the reverse remodeling after cardiac resynchronization therapy (CRT) might reduce the occurrence of ventricular arrhythmias (VAs). Background: It is currently debated whether CRT has an effect on the burden of VAs. Methods: The study included 398 patients treated with a CRT defibrillator and with a follow-up of at least 12 months. Spontaneous VAs detected by the device were reviewed and validated. Results: A significant reduction in VA episodes and shock therapies was evident during the follow-up with greater decrease after 1 month. After 6 months of CRT, 227 patients (57%) showed a reduction in end-systolic volume of ≥10% and were defined as "responders." The baseline characteristics were similar between the responders and the nonresponders. Nonetheless, the proportion of patients with recurrence of VA after 1 month of CRT was significantly lower in responders (32% vs. 43%, p = 0.024). Among baseline variables no parameters emerged as predictors of tachyarrhythmia recurrence. However, receiver-operating curve analysis recognized a reduction of left ventricular end-systolic volume at 6 months of 13% as the best cutoff to identify the reduction of VAs (with a sensitivity of 58% and a specificity of 54%). Conclusions: In patients treated with CRT defibrillators, a reduction in ventricular arrhythmic events occurs during the initial 12 months after implant and is correlated with the degree of ventricular remodeling induced by the therapy. Patients demonstrating reverse remodeling at midterm follow-up show a reduction in arrhythmias soon after the implant, pronounced improvements at long-term, and a better survival. © 2008 American College of Cardiology Foundation

    Physical activity measured by implanted devices predicts atrial arrhythmias and patient outcome: Results of IMPLANTED (Italian Multicentre Observational Registry on Patients With Implantable Devices Remotely Monitored)

    Get PDF
    Background--To determine whether daily physical activity (PA), as measured by implanted devices (through accelerometer sensor), was related to the risk of developing atrial arrhythmias during long-term follow-up in a population of heart failure (HF) patients with an implantable cardioverter defibrillator (ICD). Methods and Results--The study population was divided into 2 equally sized groups (PA cutoff point: 3.5 h/d) according to their mean daily PA recorded by the device during the 30- to 60-day period post-ICD implantation. Propensity score matching was used to compare 2 equally sized cohorts with similar characteristics between lower and higher activity patients. The primary end point was time free from the first atrial high-rate episode (AHRE) of duration 656 minutes. Secondary end points were: first AHRE 656 hours, first AHRE 6548 hours, and a combined end point of death or HF hospitalization. Data from 770 patients (65\ub115 years; 66% men; left ventricular ejection fraction 35\ub112%) remotely monitored for a median of 25 months were analyzed. A PA =3.5 h/d was associated with a 38% relative reduction in the risk of AHRE 656 minutes (72-month cumulative survival: 75.0% versus 68.1%; log rank P=0.025), and with a reduction in the risk of AHRE 656 hours, AHRE 6548 hours, and the combined end point of death or HF hospitalization (all P < 0.05). Conclusions--In HF patients with ICD, a low level of daily PA was associated with a higher risk of atrial arrhythmias, regardless of the patients' baseline characteristics. In addition, a lower daily PA predicted death or HF hospitalization

    Long-Term Implications of Atrial Fibrillation in Patients With Degenerative Mitral Regurgitation

    Get PDF
    Background: Scientific guidelines consider atrial fibrillation (AF) complicating degenerative mitral regurgitation (DMR) a debated indication for surgery. Objectives: This study analyzed the prognostic/therapeutic implications of AF at DMR diagnosis and long-term. Methods: Patients were enrolled in the MIDA (Mitral Regurgitation International Database) registry, which reported the consecutive, multicenter, international experience with DMR due to flail leaflets echocardiographically diagnosed. Results: Among 2,425 patients (age 67 \ub1 13 years; 71% male, 67% asymptomatic, ejection fraction 64 \ub1 10%), 1,646 presented at diagnosis with sinus rhythm (SR), 317 with paroxysmal AD, and 462 with persistent AF. Underlying clinical/instrumental characteristics progressively worsened from SR to paroxysmal to persistent AF. During follow-up, paroxysmal and persistent AF were associated with excess mortality (10-year survival in SR and in paroxysmal and persistent AF was 74 \ub1 1%, 59 \ub1 3%, and 46 \ub1 2%, respectively; p < 0.0001), that persisted 20 years post-diagnosis and independently of all baseline characteristics (p values <0.0001). Surgery (n = 1,889, repair 88%) was associated with better survival versus medical management, regardless of all baseline characteristics and rhythm (adjusted hazard ratio: 0.26; 95% confidence interval: 0.23 to 0.30; p < 0.0001) but post-surgical outcome remained affected by AF (10-year post-surgical survival in SR and in paroxysmal and persistent AF was 82 \ub1 1%, 70 \ub1 4%, and 57 \ub1 3%, respectively; p < 0.0001). Conclusions: AF is a frequent occurrence at DMR diagnosis. Although AF is associated with older age and more severe presentation of DMR, it is independently associated with excess mortality long-term after diagnosis. Surgery is followed by improved survival in each cardiac rhythm subset, but persistence of excess risk is observed for each type of AF. Our study indicates that detection of AF, even paroxysmal, should trigger prompt consideration for surgery
    • …
    corecore