509 research outputs found

    Design of a factorial experiment with randomization restrictions to assess medical device performance on vascular tissue

    Get PDF
    Background: Energy-based surgical scalpels are designed to efficiently transect and seal blood vessels using thermal energy to promote protein denaturation and coagulation. Assessment and design improvement of ultrasonic scalpel performance relies on both in vivo and ex vivo testing. The objective of this work was to design and implement a robust, experimental test matrix with randomization restrictions and predictive statistical power, which allowed for identification of those experimental variables that may affect the quality of the seal obtained ex vivo. Methods: The design of the experiment included three factors: temperature (two levels); the type of solution used to perfuse the artery during transection (three types); and artery type (two types) resulting in a total of twelve possible treatment combinations. Burst pressures of porcine carotid and renal arteries sealed ex vivo were assigned as the response variable. Results: The experimental test matrix was designed and carried out as a split-plot experiment in order to assess the contributions of several variables and their interactions while accounting for randomization restrictions present in the experimental setup. The statistical software package SAS was utilized and PROC MIXED was used to account for the randomization restrictions in the split-plot design. The combination of temperature, solution, and vessel type had a statistically significant impact on seal quality. Conclusions: The design and implementation of a split-plot experimental test-matrix provided a mechanism for addressing the existing technical randomization restrictions of ex vivo ultrasonic scalpel performance testing, while preserving the ability to examine the potential effects of independent factors or variables. This method for generating the experimental design and the statistical analyses of the resulting data are adaptable to a wide variety of experimental problems involving large-scale tissue-based studies of medical or experimental device efficacy and performance

    A genome-wide association study to identify genetic markers associated with endometrial cancer grade

    Get PDF
    RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are

    Low-Weight Primes for Lightweight Elliptic Curve Cryptography on 8-bit AVR Processors

    Get PDF
    Small 8-bit RISC processors and micro-controllers based on the AVR instruction set architecture are widely used in the embedded domain with applications ranging from smartcards over control systems to wireless sensor nodes. Many of these applications require asymmetric encryption or authentication, which has spurred a body of research into implementation aspects of Elliptic Curve Cryptography (ECC) on the AVR platform. In this paper, we study the suitability of a special class of finite fields, the so-called Optimal Prime Fields (OPFs), for a "lightweight" implementation of ECC with a view towards high performance and security. An OPF is a finite field Fp defined by a prime of the form p = u*2^k + v, whereby both u and v are "small" (in relation to 2^k) so that they fit into one or two registers of an AVR processor. OPFs have a low Hamming weight, which allows for a very efficient implementation of the modular reduction since only the non-zero words of p need to be processed. We describe a special variant of Montgomery multiplication for OPFs that does not execute any input-dependent conditional statements (e.g. branch instructions) and is, hence, resistant against certain side-channel attacks. When executed on an Atmel ATmega processor, a multiplication in a 160-bit OPF takes just 3237 cycles, which compares favorably with other implementations of 160-bit modular multiplication on an 8-bit processor. We also describe a performance-optimized and a security-optimized implementation of elliptic curve scalar multiplication over OPFs. The former uses a GLV curve and executes in 4.19M cycles (over a 160-bit OPF), while the latter is based on a Montgomery curve and has an execution time of approximately 5.93M cycles. Both results improve the state-of-the-art in lightweight ECC on 8-bit processors

    Genome-wide association studies and genetic architecture of common human diseases

    Get PDF
    Genome-wide association scans provide the first successful method to identify genetic variation contributing to risk for common complex disease. Progress in identifying genes associated with melanoma show complex relationships between genes for pigmentation and the development of melanoma. Novel risk loci account for only a small fraction of the genetic variation contributing to this and many other diseases. Large meta-analyses find additional variants, but there is current debate about the contribution of common polymorphisms, rare polymorphisms or mutations to disease risk

    Translocation t(7;9)(q34;q32) found in pediatric T-cell acute lymphoblastic leukemia

    Get PDF
    Case report of a translocation : Translocation t(7;9)(q34;q32) found in pediatric T-cell acute lymphoblastic leukemia

    The "Ram Effect": A "Non-Classical" Mechanism for Inducing LH Surges in Sheep

    Get PDF
    During spring sheep do not normally ovulate but exposure to a ram can induce ovulation. In some ewes an LH surge is induced immediately after exposure to a ram thus raising questions about the control of this precocious LH surge. Our first aim was to determine the plasma concentrations of oestradiol (E2) E2 in anoestrous ewes before and after the "ram effect" in ewes that had a "precocious" LH surge (starting within 6 hours), a "normal" surge (between 6 and 28h) and "late» surge (not detected by 56h). In another experiment we tested if a small increase in circulating E2 could induce an LH surge in anoestrus ewes. The concentration of E2 significantly was not different at the time of ram introduction among ewes with the three types of LH surge. "Precocious" LH surges were not preceded by a large increase in E2 unlike "normal" surges and small elevations of circulating E2 alone were unable to induce LH surges. These results show that the "precocious" LH surge was not the result of E2 positive feedback. Our second aim was to test if noradrenaline (NA) is involved in the LH response to the "ram effect". Using double labelling for Fos and tyrosine hydroxylase (TH) we showed that exposure of anoestrous ewes to a ram induced a higher density of cells positive for both in the A1 nucleus and the Locus Coeruleus complex compared to unstimulated controls. Finally, the administration by retrodialysis into the preoptic area, of NA increased the proportion of ewes with an LH response to ram odor whereas treatment with the α1 antagonist Prazosin decreased the LH pulse frequency and amplitude induced by a sexually active ram. Collectively these results suggest that in anoestrous ewes NA is involved in ram-induced LH secretion as observed in other induced ovulators

    Lambda and Antilambda polarization from deep inelastic muon scattering

    Full text link
    We report results of the first measurements of Lambda and Antilambda polarization produced in deep inelastic polarized muon scattering on the nucleon. The results are consistent with an expected trend towards positive polarization with increasing x_F. The polarizations of Lambda and Antilambda appear to have opposite signs. A large negative polarization for Lambda at low positive x_F is observed and is not explained by existing models.A possible interpretation is presented.Comment: 9 pages, 2 figure
    corecore