77 research outputs found

    Current of injury predicts adequate active lead fixation in permanent pacemaker/defibrillation leads

    Get PDF
    ObjectivesThe aim of this study was to determine whether current of injury can guide adequate placement of active-fixation pacing leads.BackgroundActive-fixation leads cause injury to the myocardium at the time of fixation, manifested as a current of injury (COI) that may result in acute elevation of pacing thresholds. The relationship of COI to subsequent improvement in pacing thresholds is not clear.MethodsSixty-five patients undergoing active-fixation lead implantation were enrolled. Current of injury was characterized as the duration of the intracardiac electrogram (EGM) and the magnitude of ST-segment elevation. Pacing parameters were measured up to 10 min after fixation.ResultsA total of 96 active-fixation leads were studied, and 76 leads had a current of injury. From baseline to the time of fixation, the duration of the intracardiac EGM in ventricular leads increased from 150 ± 31 ms to 200 ± 25 ms (p < 0.001), and the ST-segment increased from 1.5 ± 0.2 mV to 10.0 ± 2.0 mV (p < 0.001), with subsequent improvement in pacing thresholds from 1.5 ± 0.4 V to 0.8 ± 0.3 V (p < 0.001) at 10 min. Atrial leads with a current of injury had similar findings. Of the 20 leads without a COI, 5 dislodged acutely and 15 had high pacing thresholds at 10 min, requiring repositioning.ConclusionsThe development of a COI indicates that within 10 min of fixation, pacing threshold will return to an acceptable range even if the initial measurement is high. Conversely, without a COI, lead fixation is not adequate and the lead should be repositioned

    Cardiac Rehabilitation: Preliminary Results

    Get PDF
    We have always thought that patients with cardiac disease are depressed and anxious. The plan for cardiac rehab begins with exercise 3 times a week for 12 weeks. Patients are usually elderly. Typical patients are 60+ years old, inactive but stable, smoke cigarettes, are stressed, hypertensive, and anxious. After several visits the staff for the program report that patients are confident with decreased anxiety and improved exercise ability. Challenges for a rehab program are parking, education and frailness. At present we have no data on outcome (mortality, morbidity) but most measurements are improved after rehab. Outcome data after discharge for rehab program must be obtained

    Motor vehicle accidents in patients with an implantable cardioverter-defibrillator

    Get PDF
    Objectives.This study was designed to examine driving safety in patients at risk for sudden death after implantation of a cardioverter-defibrillator.Background.Cardioverter-defibrillators are frequently implanted in patients at high risk for sudden death. Despite concern about the safety of driving in these patients, little is known about their actual motor vehicle accident rates.Methods.Surveys were sent to all 742 physicians in the United States involved in cardioverter-defibrillator implantation and follow-up. Physicians were questioned about numbers of patients followed up, numbers of fatal and nonfatal accidents, physician recommendations to patients about driving and knowledge of state driving laws.Results.Surveys were returned by 452 physicians (61%). A total of 30 motor vehicle accidents related to shocks from implantable defibrillators were reported by 25 physicians over a 12-year period from 1980 to 1992. Of these, nine were fatal accidents involving eight patients with a defibrillator and one passenger in a car driven by a patient. No bystanders were fatally injured. There were 21 nonfatal accidents involving 15 patients, 3 passengers and 3 bystanders. The estimated fatality rate for patients with a defibrillator, 7.5/100,000 patient-years, is significantly lower than that for the general population (18.4/100,000 patient-years, p < 0.05). The estimated injury rate, 17.6/100,000 patient-years, is also significantly lower than that for the general public (2,224/100,000 patient-years, p < 0.05). Only 10.5% (30 of 286) of all defibrillator discharges during driving resulted in accidents. Regarding physician recommendations, most physicians (58.1%) ask their patients to wait a mean (± SD) of 7.3 ± 3.4 months after implantation or a shock before driving again.Conclusions.The motor vehicle accident rate caused by discharge from an implantable cardioverter-defibrillator is low. Although restricting driving for a short period of time after implantation may be appropriate, excessive restrictions or a total ban on driving appears to be unwarranted

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    Mortality and pulmonary complications in patients undergoing surgery with perioperative SARS-CoV-2 infection: an international cohort study

    Get PDF
    Background: The impact of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on postoperative recovery needs to be understood to inform clinical decision making during and after the COVID-19 pandemic. This study reports 30-day mortality and pulmonary complication rates in patients with perioperative SARS-CoV-2 infection. Methods: This international, multicentre, cohort study at 235 hospitals in 24 countries included all patients undergoing surgery who had SARS-CoV-2 infection confirmed within 7 days before or 30 days after surgery. The primary outcome measure was 30-day postoperative mortality and was assessed in all enrolled patients. The main secondary outcome measure was pulmonary complications, defined as pneumonia, acute respiratory distress syndrome, or unexpected postoperative ventilation. Findings: This analysis includes 1128 patients who had surgery between Jan 1 and March 31, 2020, of whom 835 (74·0%) had emergency surgery and 280 (24·8%) had elective surgery. SARS-CoV-2 infection was confirmed preoperatively in 294 (26·1%) patients. 30-day mortality was 23·8% (268 of 1128). Pulmonary complications occurred in 577 (51·2%) of 1128 patients; 30-day mortality in these patients was 38·0% (219 of 577), accounting for 81·7% (219 of 268) of all deaths. In adjusted analyses, 30-day mortality was associated with male sex (odds ratio 1·75 [95% CI 1·28–2·40], p\textless0·0001), age 70 years or older versus younger than 70 years (2·30 [1·65–3·22], p\textless0·0001), American Society of Anesthesiologists grades 3–5 versus grades 1–2 (2·35 [1·57–3·53], p\textless0·0001), malignant versus benign or obstetric diagnosis (1·55 [1·01–2·39], p=0·046), emergency versus elective surgery (1·67 [1·06–2·63], p=0·026), and major versus minor surgery (1·52 [1·01–2·31], p=0·047). Interpretation: Postoperative pulmonary complications occur in half of patients with perioperative SARS-CoV-2 infection and are associated with high mortality. Thresholds for surgery during the COVID-19 pandemic should be higher than during normal practice, particularly in men aged 70 years and older. Consideration should be given for postponing non-urgent procedures and promoting non-operative treatment to delay or avoid the need for surgery. Funding: National Institute for Health Research (NIHR), Association of Coloproctology of Great Britain and Ireland, Bowel and Cancer Research, Bowel Disease Research Foundation, Association of Upper Gastrointestinal Surgeons, British Association of Surgical Oncology, British Gynaecological Cancer Society, European Society of Coloproctology, NIHR Academy, Sarcoma UK, Vascular Society for Great Britain and Ireland, and Yorkshire Cancer Research

    Search for gravitational-lensing signatures in the full third observing run of the LIGO-Virgo network

    Get PDF
    Gravitational lensing by massive objects along the line of sight to the source causes distortions of gravitational wave-signals; such distortions may reveal information about fundamental physics, cosmology and astrophysics. In this work, we have extended the search for lensing signatures to all binary black hole events from the third observing run of the LIGO--Virgo network. We search for repeated signals from strong lensing by 1) performing targeted searches for subthreshold signals, 2) calculating the degree of overlap amongst the intrinsic parameters and sky location of pairs of signals, 3) comparing the similarities of the spectrograms amongst pairs of signals, and 4) performing dual-signal Bayesian analysis that takes into account selection effects and astrophysical knowledge. We also search for distortions to the gravitational waveform caused by 1) frequency-independent phase shifts in strongly lensed images, and 2) frequency-dependent modulation of the amplitude and phase due to point masses. None of these searches yields significant evidence for lensing. Finally, we use the non-detection of gravitational-wave lensing to constrain the lensing rate based on the latest merger-rate estimates and the fraction of dark matter composed of compact objects

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF
    corecore