30 research outputs found

    Teleradiology usage and user satisfaction with the telemedicine system operated by MĂ©decins Sans FrontiĂšres

    Get PDF
    MĂ©decins Sans FrontiĂšres (MSF) began a pilot trial of store-and-forward telemedicine in 2010, initially operating separate networks in English, French, and Spanish; these were merged into a single, multilingual platform in 2013. We reviewed the pattern of teleradiology usage on the MSF telemedicine platform in the 4-year period from April 2010. In total, 564 teleradiology cases were submitted from 22 different countries. A total of 1114 files were uploaded with the 564 cases, the majority being of type JPEG (n = 1081, 97%). The median file size was 938 kb (interquartile range, IQR 163-1659). A panel of 14 radiologists was available to report cases, but most (90%) were reported by only 4 radiologists. The median radiologist response time was 6.1 h (IQR 3.0-20). A user satisfaction survey was sent to 29 users in the last 6 months of the study. There was a 28% response rate. Most respondents found the radiologist's advice helpful and all of them stated that the advice assisted in clarification of a diagnosis. Although some MSF sites made substantial use of the system for teleradiology, there is considerable potential for expansion. More promotion of telemedicine may be needed at different levels of the organization to increase engagement of staff

    TSH-CHECK-1 test: diagnostic accuracy and potential application to initiating treatment for hypothyroidism in patients on anti-tuberculosis drugs.

    Get PDF
    Thyroid-stimulating hormone (TSH) promotes expression of thyroid hormones which are essential for metabolism, growth, and development. Second-line drugs to treat tuberculosis (TB) can cause hypothyroidism by suppressing thyroid hormone synthesis. Therefore, TSH levels are routinely measured in TB patients receiving second-line drugs, and thyroxin treatment is initiated where indicated. However, standard TSH tests are technically demanding for many low-resource settings where TB is prevalent; a simple and inexpensive test is urgently needed

    Guidelines for the use of chest radiographs in community-acquired pneumonia in children and adolescents

    Get PDF
    © 2017, The Author(s). National guidance from the United Kingdom and the United States on community-acquired pneumonia in children states that chest radiographs are not recommended routinely in uncomplicated cases. The main reason in the ambulatory setting is that there is no evidence of a substantial impact on clinical outcomes. However clinical practice and adherence to guidance is multifactorial and includes the clinical context (developed vs. developing world), the confidence of the attending physician, the changing incidence of complications (according to the success of immunisation programs), the availability of alternative imaging (and its relationship to perceived risks of radiation) and the reliability of the interpretation of imaging. In practice, chest radiographs are performed frequently for suspected pneumonia in children. Time pressures facing clinicians at the front line, difficulties in distinguishing which children require admission, restricted bed numbers for admissions, imaging-resource limitations, perceptions regarding risk from procedures, novel imaging modalities and the probability of other causes for the child’s presentation all need to be factored into a guideline. Other drivers that often weigh in, depending on the setting, include cost-effectiveness and the fear of litigation. Not all guidelines designed for the developed world can therefore be applied to the developing world, and practice guidelines require regular review in the context of new information. In addition, radiologists must improve radiographic diagnosis of pneumonia, reach consensus on the interpretive terminology that clarifies their confidence regarding the presence of pneumonia and act to replace one imaging technique with another whenever there is proof of improved accuracy or reliability

    The 2010 very high energy gamma-ray flare & 10 years of multi-wavelength observations of M 87

    Get PDF
    Abridged: The giant radio galaxy M 87 with its proximity, famous jet, and very massive black hole provides a unique opportunity to investigate the origin of very high energy (VHE; E>100 GeV) gamma-ray emission generated in relativistic outflows and the surroundings of super-massive black holes. M 87 has been established as a VHE gamma-ray emitter since 2006. The VHE gamma-ray emission displays strong variability on timescales as short as a day. In this paper, results from a joint VHE monitoring campaign on M 87 by the MAGIC and VERITAS instruments in 2010 are reported. During the campaign, a flare at VHE was detected triggering further observations at VHE (H.E.S.S.), X-rays (Chandra), and radio (43 GHz VLBA). The excellent sampling of the VHE gamma-ray light curve enables one to derive a precise temporal characterization of the flare: the single, isolated flare is well described by a two-sided exponential function with significantly different flux rise and decay times. While the overall variability pattern of the 2010 flare appears somewhat different from that of previous VHE flares in 2005 and 2008, they share very similar timescales (~day), peak fluxes (Phi(>0.35 TeV) ~= (1-3) x 10^-11 ph cm^-2 s^-1), and VHE spectra. 43 GHz VLBA radio observations of the inner jet regions indicate no enhanced flux in 2010 in contrast to observations in 2008, where an increase of the radio flux of the innermost core regions coincided with a VHE flare. On the other hand, Chandra X-ray observations taken ~3 days after the peak of the VHE gamma-ray emission reveal an enhanced flux from the core. The long-term (2001-2010) multi-wavelength light curve of M 87, spanning from radio to VHE and including data from HST, LT, VLA and EVN, is used to further investigate the origin of the VHE gamma-ray emission. No unique, common MWL signature of the three VHE flares has been identified.Comment: 19 pages, 5 figures; Corresponding authors: M. Raue, L. Stawarz, D. Mazin, P. Colin, C. M. Hui, M. Beilicke; Fig. 1 lightcurve data available online: http://www.desy.de/~mraue/m87

    Additional files HIV diagnostic accuracy study

    No full text
    Additional files HIV diagnostic accuracy study <br><br

    A guide to aid the selection of diagnostic tests

    No full text
    In recent years, a wide range of diagnostic tests has become available for use in resource-constrained settings. Accordingly, a huge number of guidelines, performance evaluations and implementation reports have been produced. However, this wealth of information is unstructured and of uneven quality, which has made it difficult for end-users, such as clinics, laboratories and health ministries, to determine which test would be best for improving clinical care and patient outcomes in a specific context. This paper outlines a six-step guide to the selection and implementation of in vitro diagnostic tests based on Medecins Sans Frontieres practical experience: (i) define the test's purpose; (ii) review the market; (iii) ascertain regulatory approval; (iv) determine the test's diagnostic accuracy under ideal conditions; (v) determine the test's diagnostic accuracy in clinical practice; and (vi) monitor the test's performance in routine use. Gaps in the information needed to complete these six steps and gaps in regulatory systems are highlighted. Finally, ways of improving the quality of diagnostic tests are suggested, such as establishing a model list of essential diagnostics, establishing a repository of information on the design of diagnostic studies and improving quality control and postmarketing surveillanc

    Quality assessment of X-rays interpreted via teleradiology for Medecins Sans Frontieres

    No full text
    Medecins Sans Frontieres (MSF) is a humanitarian organisation which provides emergency medical aid in challenging settings; field staff often diagnose and treat patients using limited resources and without the expertise of specialists. Teleradiology is available for MSF sites which use digital computed radiography (CR) imaging or conventional film and chemistry. We conducted a retrospective study of the quality of X-rays utilised by MSF for teleradiology diagnosis over a one-year period. All plain X-ray examinations referred for interpretation using two MSF teleradiology platforms in 2012 were assessed against 15 image criteria and further evaluated as being either diagnostic or non-diagnostic. The sites studied sent an average of 115 images (range 10452). Images were a mixture of chest, skeletal and abdominal radiographs. The majority of the images were CR (n = 597, 74%). Three sites were MSF/Epicentre installed and operated (Epicentre is a research facility affiliated with MSF); five sites were operated by the ministry of health, imaging patients referred by MSF. The sites performing poorest for quality were all facilities which used film and chemistry (53% non-diagnostic images). The sites performing better for quality were facilities which used CR digital imaging (12% non-diagnostic images), two of which had also undergone radiographer training. Our study suggests that transitioning to CR digital imaging has the potential to improve image quality compared to film and chemistry. Radiography training should be made a priority for all sites with X-ray services. The continued utilisation of X-ray services by MSF where images have proven to be consistently poor should be re-considered

    The impact of computed radiography and teleradiology on patients' diagnosis and treatment in Mweso, the Democratic Republic of Congo.

    No full text
    INTRODUCTION:High quality diagnostic imaging can provide increased diagnostic accuracy and help guide medical decision-making and management, however challenges for radiology in resource-limited settings are numerous. Diagnostic imaging and teleradiology have financial and logistical implications, so evidence of impact is crucial. We sought to test the hypothesis that the implementation of computed radiography with teleradiology consultation support will significantly change diagnoses and treatment plans in a resource limited setting. METHOD:Paired before-after study to determine the therapeutic impact of an add-on diagnostic test. 'Preliminary Plan' and 'Final Plan' forms allowed direct comparison of diagnosis and treatment plans at initial consultation and following radiography and teleradiology. Consecutive consenting patients were included until the sample size (600) was reached. Changes in both diagnosis and treatment plan were analysed in the whole cohort, with sub-analyses of children aged <5 years, and cases of chest radiography. RESULTS:Final analysis included 536 cases. Diagnosis changed following radiography and teleradiology in 62% of cases, and treatment plans changed in 61%. In chest radiography cases, 70% of diagnoses and 62% of treatment plans changed, while in children <5 years 66% of diagnoses and 58% of treatment plans changed. Reduced final treatment plans were most common for exploratory surgery (72% decrease), surgical orthopaedic intervention (62% decrease), and TB treatment (52% decrease), allowing more conservative medical or surgical management in 61 cases. Increased final treatment plans were highest in the orthopaedic and interventional surgery and referral categories. Of 42 cases requiring interventional surgery in the final plan, 26 (62%) were identified only after radiography and teleradiology. 16 additional cases were indicated for orthopaedic surgery, 10 cases required patient transfer, and TB treatment was indicated in 45 cases. A change in the original prescription plan occurred in 41% of 536 cases, with one or more prescriptions stopped in 28% of all cases. CONCLUSION:We found that computed radiography with teleradiology had significant clinical value in this resource-limited setting, with the potential to affect both patient outcomes and treatment costs through providing improved diagnostics and avoiding unnecessary treatments and medications
    corecore