3,829 research outputs found

    Detection of viable bacteria in environmental water samples using DNase I and PCR method. International Journal of Environmental Studies

    Get PDF
    In this study, we tested the potential application of a previously developed method in detecting Escherichia coli in environmental water samples. To increase the sensitivity of the method, and the recovery of microbial cells, water samples were filtered before being subjected to DNase treatment and polymerase chain reaction amplification. Results showed that DNase I treatment and PCR reaction were not affected by inhibitors as the expected amplicon was successfully amplified in autoclaved environmental waters spiked with E. coli. Then, we applied this method to naturally contaminated environmental water samples. We firstly confirmed the presence of coliforms and E. coli in these water samples by plating in eosin methylene blue agar. Simultaneous PCR amplification targeting Lac Z and uidR gene of total coliforms and E. coli respectively demonstrated that this developed method is potentially applicable for routine microbial assessment of health risks related to viable microorganisms in environmental or drinking waters

    Nanocasting Synthesis of Ultrafine WO3 Nanoparticles for Gas Sensing Applications

    Get PDF
    Ultrafine WO3 nanoparticles were synthesized by nanocasting route, using mesoporous SiO2 as a template. BET measurements showed a specific surface area of 700 m 2/gr for synthesized SiO2, while after impregnation and template removal, this area was reduced to 43 m 2/gr for WO3 nanoparticles. HRTEM results showed single crystalline nanoparticles with average particle size of about 5 nm possessing a monoclinic structure, which is the favorite crystal structure for gas sensing applications. Gas sensor was fabricated by deposition of WO3 nanoparticles between electrodes via low frequency AC electrophoretic deposition. Gas sensing measurements showed that this material has a high sensitivity to very low concentrations of NO2 at 250°C and 300°C

    EXACT RUN LENGTH DISTRIBUTION OF THE DOUBLE SAMPLING X CHART WITH ESTIMATED PROCESS PARAMETERS

    Get PDF
    Since the run length distribution is generally highly skewed, a significant concern about focusing too much on the average run length (ARL) criterion is that we may miss some crucial information about a control chart’s performance. Thus it is important to investigate the entire run length distribution of a control chart for an in-depth understanding before implementing the chart in process monitoring. In this paper, the percentiles of the run length distribution for the double sampling (DS) X chart with estimated process parameters are computed. Knowledge of the percentiles of the run length distribution provides a more comprehensive understanding of the expected behaviour of the run length. This additional information includes the early false alarm, the skewness of the run length distribution, and the median run length (MRL). A comparison of the run length distribution between the optimal ARL-based and MRL-based DS X chart with estimated process parameters is presented in this paper. Examples of applications are given to aid practitioners to select the best design scheme of the DS X chart with estimated process parameters, based on their specific purpose

    EXACT RUN LENGTH DISTRIBUTION OF THE DOUBLE SAMPLING X CHART WITH ESTIMATED PROCESS PARAMETERS

    Get PDF
    Since the run length distribution is generally highly skewed, a significant concern about focusing too much on the average run length (ARL) criterion is that we may miss some crucial information about a control chart’s performance. Thus it is important to investigate the entire run length distribution of a control chart for an in-depth understanding before implementing the chart in process monitoring. In this paper, the percentiles of the run length distribution for the double sampling (DS) X chart with estimated process parameters are computed. Knowledge of the percentiles of the run length distribution provides a more comprehensive understanding of the expected behaviour of the run length. This additional information includes the early false alarm, the skewness of the run length distribution, and the median run length (MRL). A comparison of the run length distribution between the optimal ARL-based and MRL-based DS X chart with estimated process parameters is presented in this paper. Examples of applications are given to aid practitioners to select the best design scheme of the DS X chart with estimated process parameters, based on their specific purpose

    Aged-senescent cells contribute to impaired heart regeneration

    Get PDF
    Aging leads to increased cellular senescence and is associated with decreased potency of tissue-specific stem/progenitor cells. Here, we have done an extensive analysis of cardiac progenitor cells (CPCs) isolated from human subjects with cardiovascular disease, aged 32-86 years. In aged subjects (>70 years old), over half of CPCs are senescent (p16INK4A , SA-β-gal, DNA damage γH2AX, telomere length, senescence-associated secretory phenotype [SASP]), unable to replicate, differentiate, regenerate or restore cardiac function following transplantation into the infarcted heart. SASP factors secreted by senescent CPCs renders otherwise healthy CPCs to senescence. Elimination of senescent CPCs using senolytics abrogates the SASP and its debilitative effect in vitro. Global elimination of senescent cells in aged mice (INK-ATTAC or wild-type mice treated with D + Q senolytics) in vivo activates resident CPCs and increased the number of small Ki67-, EdU-positive cardiomyocytes. Therapeutic approaches that eliminate senescent cells may alleviate cardiac deterioration with aging and restore the regenerative capacity of the heart

    Outpatient-Based Therapy of Oral Fludarabine and Subcutaneous Alemtuzumab for Asian Patients with Relapsed/Refractory Chronic Lymphocytic Leukemia

    Get PDF
    Background. Intravenous alemtuzumab and fludarabine are effective in combination for the treatment of chronic lymphocytic leukemia (CLL), but require hospital visits for intravenous injection. We performed a pilot study to assess the safety and efficacy of outpatient-based oral fludarabine with subcutaneous alemtuzumab (OFSA) for the treatment of relapsed/refractory CLL. Results. Depending on their response, patients were given two to six 28-day cycles of subcutaneous alemtuzumab 30 mg on days 1,3, and 5 and oral fludarabine 40 mg/m2/day for 5 days. Median patient age was 74. The lymphocyte counts of all five patients fell after the 1st cycle of treatment and reached normal/low levels on completion of 2 to 6 cycles of therapy. Platelet counts and hemoglobin were unaffected. All five patients achieved complete hematological remission, while two attained minimal residual disease negativity on 4-color flow cytometry. Conclusions. Our OFSA regimen was effective in elderly Asian patients with relapsed/refractory CLL, and it should be investigated further

    TOpic: rare and special cases, the real "Strange cases"

    Get PDF
    Introduction: The bladder hernia represents approximately 1-3% of all inguinal hernias, where patients aged more than 50 years have a higher incidence (10%). Many factors contribute to the development of a bladder hernia, including the presence of a urinary outlet obstruction causing chronic bladder distention, the loss of bladder tone, pericystitis, the perivesical bladder fat protrusion and the obesity

    Measurement of the cross-section and charge asymmetry of WW bosons produced in proton-proton collisions at s=8\sqrt{s}=8 TeV with the ATLAS detector

    Get PDF
    This paper presents measurements of the W+μ+νW^+ \rightarrow \mu^+\nu and WμνW^- \rightarrow \mu^-\nu cross-sections and the associated charge asymmetry as a function of the absolute pseudorapidity of the decay muon. The data were collected in proton--proton collisions at a centre-of-mass energy of 8 TeV with the ATLAS experiment at the LHC and correspond to a total integrated luminosity of 20.2~\mbox{fb^{-1}}. The precision of the cross-section measurements varies between 0.8% to 1.5% as a function of the pseudorapidity, excluding the 1.9% uncertainty on the integrated luminosity. The charge asymmetry is measured with an uncertainty between 0.002 and 0.003. The results are compared with predictions based on next-to-next-to-leading-order calculations with various parton distribution functions and have the sensitivity to discriminate between them.Comment: 38 pages in total, author list starting page 22, 5 figures, 4 tables, submitted to EPJC. All figures including auxiliary figures are available at https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/STDM-2017-13
    corecore