742 research outputs found
A geometrical calibration method for the PIXSCAN micro-CT scanner
Reconstruction in Cone-Beam Tomography can suffer from artifacts due to geometrical misalignments of the source-detector system. They can be avoided by a complete and precise description of the system. We present a high precision method for the geometric calibration for the PIXSCAN, a small animal X-ray CT scanner demonstrator based on hybrid pixel detectors (XPAD2). The specificities of the XPAD2 detectors (dead pixels, tilts and gaps between modules...) made the calibration of the PIXSCAN quite difficult. The method uses a calibration object consisting of a hollow cylinder of polycarbonate on which we positioned four metallic balls. It requires 360 X-ray images (1° increments). An analytic expression of the 3 image ellipses has been derived. It is used for a least square regression of the 13 alignment parameters after a correction of the internal XPAD2 geometry. Our method is fast and completely automated, achieving a precision of about 30 μm
Component Separation for Spectral X-Ray Imaging Using the XPAD3 Hybrid Pixel Camera
The advent of hybrid pixel cameras in X-ray imaging opens the way to the acquisition of spectral measurements. These new devices for which photon counting replaces charge integration incorporate a dedicated readout electronic for each pixel including a capability of selecting energies via the setup of an energy threshold. This ability is of uppermost importance for the development of new polychromatic X-ray imaging approaches that will exploit spectral information on the detected X-rays. Spectral measurements in X-ray imaging pave the way to the separation of images in several components of physical and biological interest: the photoelectric and the Compton contributions can be separated while several contrast agents can be simultaneously localized. We investigate the capability to perform component separation by using the newly developed XPAD3 hybrid pixel camera incorporated in the micro-CT demonstrator PIXSCAN. Firstly, we propose an approach to configure the acquisition setup in order to optimize the component separation problem with respect to the robustness to the photon noise. The method is based on the Cramer-Rao Bound (CRB) that indicates the lowest reachable variance for the estimation of each component whatever the algorithm. Secondly, we investigate the separation problem with two components namely the photoelectric and the Compton ones. We show on noisy simulated data that such a separation with optimized setup i) enhances the contrast and the Contrast to Noise Ratio (CNR) between biological materials (adipose, soft tissues) and water; ii) cancels the artifacts of the beam-hardening effect that may strongly degrade the image quality. On going work involves two steps: first, dealing with Monte Carlo simulations and real data acquired with the PIXSCAN demonstrator; second, dealing with component separation with more than two components by adding several contrast agents, for which PIXSCAN has already proved its ability to separate them
Probing Dark Energy with Supernovae : a concordant or a convergent model?
We present a revised interpretation of recent analysis of supernovae data. We
evaluate the effect of the priors on the extraction of the dark energy equation
of state. We find that the conclusions depend strongly on the prior
value and on its uncertainty, and show that a biased fitting procedure applied
on non concordant simulated data can converge to the "concordance model".
Relaxing the prior on points to other sets of solutions, which are
not excluded by observational data.Comment: 1+4 pages, 6 figures, submitted to Phys. Re
Reducing Zero-point Systematics in Dark Energy Supernova Experiments
We study the effect of filter zero-point uncertainties on future supernova
dark energy missions. Fitting for calibration parameters using simultaneous
analysis of all Type Ia supernova standard candles achieves a significant
improvement over more traditional fit methods. This conclusion is robust under
diverse experimental configurations (number of observed supernovae, maximum
survey redshift, inclusion of additional systematics). This approach to
supernova fitting considerably eases otherwise stringent mission calibration
requirements. As an example we simulate a space-based mission based on the
proposed JDEM satellite; however the method and conclusions are general and
valid for any future supernova dark energy mission, ground or space-based.Comment: 30 pages,8 figures, 5 table, one reference added, submitted to
Astroparticle Physic
Weak Lensing from Space I: Instrumentation and Survey Strategy
A wide field space-based imaging telescope is necessary to fully exploit the
technique of observing dark matter via weak gravitational lensing. This first
paper in a three part series outlines the survey strategies and relevant
instrumental parameters for such a mission. As a concrete example of hardware
design, we consider the proposed Supernova/Acceleration Probe (SNAP). Using
SNAP engineering models, we quantify the major contributions to this
telescope's Point Spread Function (PSF). These PSF contributions are relevant
to any similar wide field space telescope. We further show that the PSF of SNAP
or a similar telescope will be smaller than current ground-based PSFs, and more
isotropic and stable over time than the PSF of the Hubble Space Telescope. We
outline survey strategies for two different regimes - a ``wide'' 300 square
degree survey and a ``deep'' 15 square degree survey that will accomplish
various weak lensing goals including statistical studies and dark matter
mapping.Comment: 25 pages, 8 figures, 1 table, replaced with Published Versio
Supernova / Acceleration Probe: A Satellite Experiment to Study the Nature of the Dark Energy
The Supernova / Acceleration Probe (SNAP) is a proposed space-based
experiment designed to study the dark energy and alternative explanations of
the acceleration of the Universe's expansion by performing a series of
complementary systematics-controlled measurements. We describe a
self-consistent reference mission design for building a Type Ia supernova
Hubble diagram and for performing a wide-area weak gravitational lensing study.
A 2-m wide-field telescope feeds a focal plane consisting of a 0.7
square-degree imager tiled with equal areas of optical CCDs and near infrared
sensors, and a high-efficiency low-resolution integral field spectrograph. The
SNAP mission will obtain high-signal-to-noise calibrated light-curves and
spectra for several thousand supernovae at redshifts between z=0.1 and 1.7. A
wide-field survey covering one thousand square degrees resolves ~100 galaxies
per square arcminute. If we assume we live in a cosmological-constant-dominated
Universe, the matter density, dark energy density, and flatness of space can
all be measured with SNAP supernova and weak-lensing measurements to a
systematics-limited accuracy of 1%. For a flat universe, the
density-to-pressure ratio of dark energy can be similarly measured to 5% for
the present value w0 and ~0.1 for the time variation w'. The large survey area,
depth, spatial resolution, time-sampling, and nine-band optical to NIR
photometry will support additional independent and/or complementary dark-energy
measurement approaches as well as a broad range of auxiliary science programs.
(Abridged)Comment: 40 pages, 18 figures, submitted to PASP, http://snap.lbl.go
Search for the glueball candidates f0(1500) and fJ(1710) in gamma gamma collisions
Data taken with the ALEPH detector at LEP1 have been used to search for gamma
gamma production of the glueball candidates f0(1500) and fJ(1710) via their
decay to pi+pi-. No signal is observed and upper limits to the product of gamma
gamma width and pi+pi- branching ratio of the f0(1500) and the fJ(1710) have
been measured to be Gamma_(gamma gamma -> f0(1500)). BR(f0(1500)->pi+pi-) <
0.31 keV and Gamma_(gamma gamma -> fJ(1710)). BR(fJ(1710)->pi+pi-) < 0.55 keV
at 95% confidence level.Comment: 10 pages, 3 figure
Search for CP Violation in the Decay Z -> b (b bar) g
About three million hadronic decays of the Z collected by ALEPH in the years
1991-1994 are used to search for anomalous CP violation beyond the Standard
Model in the decay Z -> b \bar{b} g. The study is performed by analyzing
angular correlations between the two quarks and the gluon in three-jet events
and by measuring the differential two-jet rate. No signal of CP violation is
found. For the combinations of anomalous CP violating couplings, and , limits of \hat{h}_b < 0.59h^{\ast}_{b} < 3.02$ are given at 95\% CL.Comment: 8 pages, 1 postscript figure, uses here.sty, epsfig.st
Two Loop Scalar Self-Mass during Inflation
We work in the locally de Sitter background of an inflating universe and
consider a massless, minimally coupled scalar with a quartic self-interaction.
We use dimensional regularization to compute the fully renormalized scalar
self-mass-squared at one and two loop order for a state which is released in
Bunch-Davies vacuum at t=0. Although the field strength and coupling constant
renormalizations are identical to those of lfat space, the geometry induces a
non-zero mass renormalization. The finite part also shows a sort of growing
mass that competes with the classical force in eventually turning off this
system's super-acceleration.Comment: 31 pages, 5 figures, revtex4, revised for publication with extended
list of reference
- …