29 research outputs found

    The effect of thermal processing in oil on the macromolecular integrity and acrylamide formation from starch of three potato cultivars organically fertilized

    Get PDF
    Starches from three organically produced cultivars of potato tuber (Lady Rosetta, Spunta and Voyager) have been studied in relation to (i) acrylamide production (ii) macromolecular integrity after frying with extra virgin olive oil, soybean oil and corn oil. During cultivation, a treatment involving the combination of nitrogen, phosphorus and potassium fertilization under organic farming was applied (N1, P2, K1 where Ν1 = 1.3 g Ν per plant, P2 = 5.2 g P2O5 per plant, Κ1 = 4.0 g K2O per plant). Potatoes fried in olive oil retained the highest glucose concentrations for all cultivars 0.85 ± 0.2 mmol/kg, followed by 0.48 ± 0.2 for those fried in corn oil and 0.40 ± 0.1 mmol/kg for those fried in soybean oil. The highest average fructose concentration was recorded for the samples fried in corn oil as 0.81 ± 0.2, followed by 0.80 ± 0.2 and 0.68 ± 0.3 mmol/kg for the samples fried in olive and soybean oils, respectively. Asparagine was the most abundant free amino acid in the three varieties tested, followed by glutamine and aspartic acid. The mean initial concentration of asparagine in raw potatoes tubers was 42.8 ± 1.6 mmoles kg−1 for Lady Rosetta, 34.6 ± 1.2 mmoles kg−1 (dry weight) for Spunta and 36.2 ± 2.0 mmoles kg−1 for Voyager. Lady Rosetta contained a significantly higher concentration of asparagine compared to the other two varieties (p < 0.05). The greatest quantity of acrylamide was observed in French fries derived from the potato variety Lady Rosetta when fried in soybean oil and it was 2,600 ± 440 μg/kg, followed by Spunta which was 2,280 ± 340 μg/kg and Voyager 1,120 ± 220 μg/kg. There is a significant reduction in the formation of acrylamide in the variety Voyager compared to the others (p = 0.05)

    Synthesis and characterization of mixed ligand chiral nanoclusters

    Get PDF
    Chiral mixed ligand silver nanoclusters were synthesized in the presence of a chiral and an achiral ligand. The ratio of the ligands was changed to track the formation of these clusters. While the chiral ligand lead to nanoparticles, Presence of the achiral ligand induced the formation of nanoclusters with chiral properties

    Genetic improvement of tomato by targeted control of fruit softening

    Get PDF
    Controlling the rate of softening to extend shelf life was a key target for researchers engineering genetically modified (GM) tomatoes in the 1990s, but only modest improvements were achieved. Hybrids grown nowadays contain 'non-ripening mutations' that slow ripening and improve shelf life, but adversely affect flavor and color. We report substantial, targeted control of tomato softening, without affecting other aspects of ripening, by silencing a gene encoding a pectate lyase

    A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    The effective time of centrifugation for the analysis of boundary spreading in sedimentation velocity experiments

    No full text
    This investigation establishes a likely order of magnitude for the zero-time correction factor governing the effective time of centrifugation that is pertinent in the analysis of boundary spreading in sedimentation velocity experiments. This correction is shown to be too small to unduly affect the magnitudes of sedimentation and diffusion coefficients deduced from the application of computer software incorporating the printout value of ω t and an effective position of the air-solution meniscus that is obtained as an additional parameter in the analysis involving nonlinear least-squares curve-fitting of sedimentation velocity distributions to the Lamm equation. Although this procedure slightly underestimates the actual meniscus position (r ), uncertainty about its exact location precludes adoption of the alternative approach with r fixed and the correction to ω t regarded as the additional curve-fitting parameter

    Interaction studies of a protein and carbohydrate system using an integrated approach: a case study of the miniagrin-heparin system

    No full text
    The major challenges in biophysical characterization of human protein-carbohydrate interactions are obtaining monodispersed preparations of human proteins that are often post-translationally modified and lack of detection of carbohydrates by traditional detection systems. Light scattering (dynamic and static) techniques offer detection of biomolecules and their complexes based on their size and shape, and do not rely on chromophore groups (such as aromatic amino acid sidechains). In this study, we utilized dynamic light scattering, analytical ultracentrifugation and small-angle X-ray scattering techniques to investigate the solution properties of a complex resulting from the interaction between a 15\ua0kDa heparin preparation and miniagrin, a miniaturized version of agrin. Results from dynamic light scattering, sedimentation equilibrium, and sedimentation velocity experiments signify the formation of a monodisperse complex with 1:1 stoichiometry, and low-resolution structures derived from the small-angle X-ray scattering measurements implicate an extended conformation for a side-by-side miniagrin‒heparin complex

    Evidence for self-association of a miniaturized version of agrin from hydrodynamic and small-angle X-ray scattering measurements

    No full text
    Hydrodynamic studies of miniagrin indicate a molar mass that is 20% larger than the value calculated from the sequence of this genetically engineered protein. Consistent with this finding is the negative sign and also the magnitude of the second virial coefficient obtained from small-angle X-ray scattering measurements. The inference that miniagrin reversibly self-associates is confirmed by a sedimentation equilibrium study that yields an equilibrium constant of 0.24 L/g for a putative monomer-dimer interaction. Finally, Guinier analysis of the small-angle X-ray scattering (SAXS) results yields concentration-dependent values for the radius of gyration that may be described by the monomer-dimer model and respective R values of 40 and 105 Å for the monomeric and dimeric miniagrin species. Although intermolecular protein interactions are endemic in the events leading to acetylcholine receptor aggregation by agrin, the matrix proteoglycan of which miniagrin is a miniaturized model, this investigation raises the possibility that agrin may itself self-associate
    corecore