161 research outputs found

    GeoBoids: A Mobile AR Application for Exergaming

    Get PDF
    “© © 2012 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.”We have designed a mobile Augmented Reality (AR) game which incorporates video see-through and spatialized audio AR techniques and encourages player movement in the real world. In the game, called GeoBoids, the player is surrounded by flocks of virtual creatures that are visible and audible through mobile AR application. The goal is for the player to run to the location of a GeoBoid swarm in the real world, capture all the creatures there, then run to the next swarm and repeat, before time runs out, encouraging the player to exercise during game play. The most novel elements of the game are the use of audio input and output for interacting with the creatures. The interface design of the game includes AR visualization, spatialized audio, touch gestures and whistle interaction. Feedback from users in a preliminary user study was mostly positive on overall game play and the design of the UI, while the results also revealed improvements were needed for whistle interaction and the visual design of the GeoBoids

    Optical spectroscopy studies of Cu2ZnSnSe4 thin films

    Get PDF
    Cu2ZnSnSe4 thin films were synthesised by selenisation of magnetron sputtered metal precursors. The band gap determined from the absorption spectra increases from 1.01 eV at 300 K to 1.05 eV at 4.2 K. In lower quality films photoluminescence spectra show a broad, low intensity asymmetric band associated with a recombination of free electrons and holes localised on acceptors in the presence of spatial potential fluctuations. In high quality material the luminescence band becomes intense and narrow resolving two phonon replicas. Its shifts at changing excitation power suggest donor–acceptor pair recombination mechanisms. The proposed model involving two pairs of donors and acceptors is supported by the evolution of the band intensity and spectral position with temperature. Energy levels of the donors and acceptors are estimated using Arrhenius quenching analysis

    Considering discrepancy when calibrating a mechanistic electrophysiology model

    Get PDF
    Uncertainty quantification (UQ) is a vital step in using mathematical models and simulations to take decisions. The field of cardiac simulation has begun to explore and adopt UQ methods to characterize uncertainty in model inputs and how that propagates through to outputs or predictions; examples of this can be seen in the papers of this issue. In this review and perspective piece, we draw attention to an important and under-addressed source of uncertainty in our predictions—that of uncertainty in the model structure or the equations themselves. The difference between imperfect models and reality is termed model discrepancy, and we are often uncertain as to the size and consequences of this discrepancy. Here, we provide two examples of the consequences of discrepancy when calibrating models at the ion channel and action potential scales. Furthermore, we attempt to account for this discrepancy when calibrating and validating an ion channel model using different methods, based on modelling the discrepancy using Gaussian processes and autoregressive-moving-average models, then highlight the advantages and shortcomings of each approach. Finally, suggestions and lines of enquiry for future work are provided. This article is part of the theme issue ‘Uncertainty quantification in cardiac and cardiovascular modelling and simulation’

    Detecting a stochastic gravitational wave background with the Laser Interferometer Space Antenna

    Get PDF
    The random superposition of many weak sources will produce a stochastic background of gravitational waves that may dominate the response of the LISA (Laser Interferometer Space Antenna) gravitational wave observatory. Unless something can be done to distinguish between a stochastic background and detector noise, the two will combine to form an effective noise floor for the detector. Two methods have been proposed to solve this problem. The first is to cross-correlate the output of two independent interferometers. The second is an ingenious scheme for monitoring the instrument noise by operating LISA as a Sagnac interferometer. Here we derive the optimal orbital alignment for cross-correlating a pair of LISA detectors, and provide the first analytic derivation of the Sagnac sensitivity curve.Comment: 9 pages, 11 figures. Significant changes to the noise estimate

    On the selection of AGN neutrino source candidates for a source stacking analysis with neutrino telescopes

    Get PDF
    The sensitivity of a search for sources of TeV neutrinos can be improved by grouping potential sources together into generic classes in a procedure that is known as source stacking. In this paper, we define catalogs of Active Galactic Nuclei (AGN) and use them to perform a source stacking analysis. The grouping of AGN into classes is done in two steps: first, AGN classes are defined, then, sources to be stacked are selected assuming that a potential neutrino flux is linearly correlated with the photon luminosity in a certain energy band (radio, IR, optical, keV, GeV, TeV). Lacking any secure detailed knowledge on neutrino production in AGN, this correlation is motivated by hadronic AGN models, as briefly reviewed in this paper. The source stacking search for neutrinos from generic AGN classes is illustrated using the data collected by the AMANDA-II high energy neutrino detector during the year 2000. No significant excess for any of the suggested groups was found.Comment: 43 pages, 12 figures, accepted by Astroparticle Physic

    All-particle cosmic ray energy spectrum measured with 26 IceTop stations

    Full text link
    We report on a measurement of the cosmic ray energy spectrum with the IceTop air shower array, the surface component of the IceCube Neutrino Observatory at the South Pole. The data used in this analysis were taken between June and October, 2007, with 26 surface stations operational at that time, corresponding to about one third of the final array. The fiducial area used in this analysis was 0.122 km^2. The analysis investigated the energy spectrum from 1 to 100 PeV measured for three different zenith angle ranges between 0{\deg} and 46{\deg}. Because of the isotropy of cosmic rays in this energy range the spectra from all zenith angle intervals have to agree. The cosmic-ray energy spectrum was determined under different assumptions on the primary mass composition. Good agreement of spectra in the three zenith angle ranges was found for the assumption of pure proton and a simple two-component model. For zenith angles {\theta} < 30{\deg}, where the mass dependence is smallest, the knee in the cosmic ray energy spectrum was observed between 3.5 and 4.32 PeV, depending on composition assumption. Spectral indices above the knee range from -3.08 to -3.11 depending on primary mass composition assumption. Moreover, an indication of a flattening of the spectrum above 22 PeV were observed.Comment: 38 pages, 17 figure

    An improved method for measuring muon energy using the truncated mean of dE/dx

    Full text link
    The measurement of muon energy is critical for many analyses in large Cherenkov detectors, particularly those that involve separating extraterrestrial neutrinos from the atmospheric neutrino background. Muon energy has traditionally been determined by measuring the specific energy loss (dE/dx) along the muon's path and relating the dE/dx to the muon energy. Because high-energy muons (E_mu > 1 TeV) lose energy randomly, the spread in dE/dx values is quite large, leading to a typical energy resolution of 0.29 in log10(E_mu) for a muon observed over a 1 km path length in the IceCube detector. In this paper, we present an improved method that uses a truncated mean and other techniques to determine the muon energy. The muon track is divided into separate segments with individual dE/dx values. The elimination of segments with the highest dE/dx results in an overall dE/dx that is more closely correlated to the muon energy. This method results in an energy resolution of 0.22 in log10(E_mu), which gives a 26% improvement. This technique is applicable to any large water or ice detector and potentially to large scintillator or liquid argon detectors.Comment: 12 pages, 16 figure

    Pension reform, the stock market, capital formation and economic growth: a critical commentary on the World Bank's proposals

    Get PDF
    Abstract Proposing far-reaching reforms to the pension systems, the World Bank has recently suggested that the existing pay-as-you-go pension systems in many rich as well as poor countries, should be replaced by fully funded, mandatory, preferably private pensions, as the main pillars of the new system. It argues that these reforms will not only benefit the pensioners, but also enhance savings, promote capital formation and economic development. This paper provides a critical examination of the Bank's theses and concludes that it has adopted a one-sided view of the relationships between the key critical variables. The proposed reform may therefore neither protect the old nor achieve faster economic growth
    corecore