568 research outputs found
Structural and Topographic Dynamics of Pulmonary Histopathology and Local Cytokine Profiles in Paracoccidioides brasiliensis Conidia-Infected Mice
Paracoccidioidomycosis (PCM), an endemic fungal infection of pulmonary origin resulting in severe disseminated disease, occurs in rural areas of most South American countries and presents several clinical forms. The infection is acquired by inhalation of specific fungal propagules, called conidia. Considering the difficulties encountered when studying the infection in humans, this work was done in mice infected by inhalation of infective fungal conidia thus mimicking the human natural infection. The lungs of mice were sequentially studied by histopathological and multiplex cytokine methods from 2 h to 16 weeks after infection to verify the course of the disease. The mycosis presented different morphologic aspects during the course of time, affecting several pulmonary compartments. Otherwise and based on the analysis of 30 cytokines, the immune response also showed heterogeneous responses, which were up or down regulated depending on the time of infection. By recognizing the different stages that correspond to the evolution of pulmonary lesions, the severity (benign, chronic or fibrotic) of the disease could be predicted and the probable prognosis of the illness be inferred
Effect of chemical degradation followed by toothbrushing on the surface roughness of restorative composites
OBJECTIVES: The aim of the present study was to assess the effect of the exposure to food-simulating liquids prior to brushing simulation on the surface roughness of five composite materials (Quixfil, Filtek Supreme, Esthet-X, Filtek Z250, Tetric Ceram). MATERIAL AND METHODS: Twenty cylinders (5 mm diameter and 4 mm height) of each composite were randomly allocated to 4 groups (n=5), according to the food-simulating liquid in which they were immersed for 7 days at 37ºC: artificial saliva, heptane, citric acid, and ethanol. After this period, the top surface of composite cylinders was submitted to 7,500 brushing cycles (200 g load). Measurements of the surface roughness (Ra, µm) were carried out before and after the exposure to the chemicals/brushing simulation. Changes on the morphology of composite surfaces were observed through scanning electron microscopy (SEM). RESULTS: The statistical analysis (ANOVA with cofactor / Tukey's test, α=5%) detected a significant interaction between solutions and composite resins. Esthet-X, Filtek Z250 and Tetric Ceram were not affected by the food-simulating liquids/toothbrushing. Citric acid and ethanol increased the surface roughness of Quixfil and Filtek Supreme, respectively. SEM images corroborate the surface roughness findings, demonstrating the negative effect from chemical solutions and mechanical abrasion. CONCLUSIONS: The surface roughness of composite resin materials are differently affected by the food-simulating solutions, depending on the immersion media
Study of decays to the final state and evidence for the decay
A study of decays is performed for the first time
using data corresponding to an integrated luminosity of 3.0
collected by the LHCb experiment in collisions at centre-of-mass energies
of and TeV. Evidence for the decay
is reported with a significance of 4.0 standard deviations, resulting in the
measurement of
to
be .
Here denotes a branching fraction while and
are the production cross-sections for and mesons.
An indication of weak annihilation is found for the region
, with a significance of
2.4 standard deviations.Comment: All figures and tables, along with any supplementary material and
additional information, are available at
https://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-PAPER-2016-022.html,
link to supplemental material inserted in the reference
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
Recommended from our members
Search for top squarks in the four-body decay mode with single lepton final states in proton-proton collisions at √s = 13 TeV
A preprint version of the article is available at arXiv:2301.08096v2 [hep-ex], https://arxiv.org/abs/2301.08096 . Comments: Replaced with the published version. Added the journal reference and the DOI. All the figures and tables can be found at https://cms-results.web.cern.ch/cms-results/public-results/publications/SUS-21-003 (CMS Public Pages).A search for the pair production of the lightest supersymmetric partner of the top quark, the top squark (t ~1), is presented. The search targets the four-body decay of the t ~1 , which is preferred when the mass difference between the top squark and the lightest supersymmetric particle is smaller than the mass of the W boson. This decay mode consists of a bottom quark, two other fermions, and the lightest neutralino (χ~10), which is assumed to be the lightest supersymmetric particle. The data correspond to an integrated luminosity of 138 fb−1 of proton-proton collisions at a center-of-mass energy of 13 TeV collected by the CMS experiment at the CERN LHC. Events are selected using the presence of a high-momentum jet, an electron or muon with low transverse momentum, and a significant missing transverse momentum. The signal is selected based on a multivariate approach that is optimized for the difference between m(t ~1) and m(χ~10). The contribution from leading background processes is estimated from data. No significant excess is observed above the expectation from standard model processes. The results of this search exclude top squarks at 95% confidence level for masses up to 480 and 700 GeV for m(t ~1) − m(χ~10) = 10 and 80 GeV, respectively. [Figure not available: see fulltext.].SCOAP3
- …