19 research outputs found

    Effects of High-Intensity Warm-Up on 5000-Meter Performance Time in Trained Long-Distance Runners

    Full text link
    Warm-up protocols with high intensities before continuous running provide potential benefits for middle-distance runners. Nevertheless, the effect of high-intensity warm-ups on long-distance runners remains unclear. The purpose of this study was to verify the effect of a high-intensity warm-up protocol on 5000 m performance in trained runners. Thirteen male runners (34 ± 10 years, 62 ± 6 kg, 62.7 ± 5.5 ml/kg/min) performed two 5000 m time trials, preceded by two different warm-ups. One high-intensity warm up (HIWU: 1x 500 m (70% of the running intensity) + 3x 250 m (100% of the running intensity) and one low-intensity warm up (LIWU: 1x 500 m (70% of the running intensity) + 3x 250 m (70% of the running intensity)), where the running intensities were calculated using the results obtained in the Cooper test. Physiological and metabolic responses, and endurance running performance parameters, were evaluated by the Counter Movement Jump (CMJ), running rating of perceived exertion (RPE), blood lactate concentration (BLa), and performance running. Total time for the 5000 m was lower using HIWU when compared to LIWU (1141.4 ± 110.4 s vs. 1147.8 ± 111.0 s; p = 0.03; Hedges' g = 0.66). The HIWU warm-up led to an improvement in pacing strategy during the time trial. After warm-up protocols, the performance on the CMJ was improved only when applying HIWU (p = 0.008). Post warm-up BLa was significantly higher for HIWU vs. LIWU (3.5 ± 1.0 mmol·L-1 vs. 2.3 ± 1.0 mmol·L-1; p = 0.02), with similar behavior for the RPE (p = 0.002), internal load of the session (p = 0.03). The study showed that a high-intensity warm-up protocol can improve performance in the 5000 m in trained endurance runners

    Effects of High-Intensity Warm-Up on 5000-Meter Performance Time in Trained Long-Distance Runners

    Get PDF
    Warm-up protocols with high intensities before continuous running provide potential benefits for middle-distance runners. Nevertheless, the effect of high-intensity warm-ups on long-distance runners remains unclear. The purpose of this study was to verify the effect of a high-intensity warm-up protocol on 5000 m performance in trained runners. Thirteen male runners (34 ± 10 years, 62 ± 6 kg, 62.7 ± 5.5 ml/kg/min) performed two 5000 m time trials, preceded by two different warm-ups. One high-intensity warm up (HIWU: 1x 500 m (70% of the running intensity) + 3x 250 m (100% of the running intensity) and one low-intensity warm up (LIWU: 1x 500 m (70% of the running intensity) + 3x 250 m (70% of the running intensity)), where the running intensities were calculated using the results obtained in the Cooper test. Physiological and metabolic responses, and endurance running performance parameters, were evaluated by the Counter Movement Jump (CMJ), running rating of perceived exertion (RPE), blood lactate concentration (BLa), and performance running. Total time for the 5000 m was lower using HIWU when compared to LIWU (1141.4 ± 110.4 s vs. 1147.8 ± 111.0 s; p = 0.03; Hedges' g = 0.66). The HIWU warm-up led to an improvement in pacing strategy during the time trial. After warm-up protocols, the performance on the CMJ was improved only when applying HIWU (p = 0.008). Post warm-up BLa was significantly higher for HIWU vs. LIWU (3.5 ± 1.0 mmol·L-1 vs. 2.3 ± 1.0 mmol·L-1; p = 0.02), with similar behavior for the RPE (p = 0.002), internal load of the session (p = 0.03). The study showed that a high-intensity warm-up protocol can improve performance in the 5000 m in trained endurance runners

    Käytännön kosteikkosuunnittelu

    Get PDF
    Maatalouden vesiensuojelua edistetään monin tavoin. Ravinteita ja eroosioainesta sisältäviä valumavesiä pyritään puhdistamaan erilaisissa kosteikoissa. Tämä opas on kirjoitettu avuksi pienimuotoisten kosteikkojen perustamiseen. Oppaassa esitetään käytännönläheisesti kosteikon toteuttamisen eri vaiheet paikan valinnasta suunnitteluun ja rakentamiseen. Vuonna 2010 julkaistun painoksen tiedot on saatettu ajantasalle. Julkaisu on toteutettu osana Tehoa maatalouden vesiensuojeluun (TEHO) -hanketta ja päivitetty TEHO Plus -hankkeen toimesta. Oppaan toivotaan lisäävän kiinnostusta kosteikkojen suunnitteluun ja edelleen niiden rakentamiseen

    Multicriteria decision making for sustainable development: A systematic review

    No full text

    Interpretation of the depths of maximum of extensive air showers measured by the Pierre Auger Observatory

    No full text

    The Pierre Auger Observatory: Contributions to the 33rd International Cosmic Ray Conference (ICRC 2013)

    No full text

    The Pierre Auger Observatory: Contributions to the 33rd International Cosmic Ray Conference (ICRC 2013)

    No full text

    The Pierre Auger Observatory: Contributions to the 33rd International Cosmic Ray Conference (ICRC 2013)

    No full text
    Contributions of the Pierre Auger Collaboration to the 33rd International Cosmic Ray Conference, Rio de Janeiro, Brazil, July 201

    Publisher’s Note: Muons in air showers at the Pierre Auger Observatory: Measurement of atmospheric production depth [Phys. Rev. D 90, 012012 (2014)]

    No full text
    corecore