123 research outputs found

    Positional distribution of human transcription factor binding sites

    Get PDF
    We developed a method for estimating the positional distribution of transcription fac-tor (TF) binding sites using ChIP-chip data, and applied it to recently published experiments on binding sites of nine TFs; OCT4, SOX2, NANOG, HNF1A, HNF4A, HNF6, FOXA2, USF1 and CREB1. The data were obtained from a genome-wide cov-erage of promoter regions from 8kb upstream of the Transcription Start Site (TSS) to 2kb downstream. The number of target genes of each TF ranges from few hundred to several thousand. We found that for each of the nine TFs the estimated binding site distribution is closely approximated by a mixture of two components: a narrow peak, localized within 300 base pairs upstream of the TSS, and a distribution of almost uni-form density within the tested region. Using Gene Ontology and Enrichment analysis, we were able to associate (for each of the TFs studied) the target genes of both types of binding with known biological processes. Most GO terms were enriched either among the proximal targets or among those with a uniform distribution of binding sites. For example, the three stemness-related TFs have several hundred target genes that belong to "development" and "morphogenesis" whose binding sites belong to the uniform dis-tribution.Comment: 27 pages, 8 figures (already embedded in file) To appear in Nucleic Acids Researc

    Simultaneous identification of Chlamydia trachomatis, Neisseria gonorrhoeae, Mycoplasma genitalium, and Trichomonas vaginalis ‒ multicenter evaluation of the Alinity m STI assay

    Get PDF
    Abstract Objectives Accurate and rapid diagnosis of sexually transmitted infections (STIs) is essential for timely administration of appropriate treatment and reducing the spread of the disease. We examined the performance of the new Alinity m STI assay, a qualitative real-time multiplex PCR test for simultaneous identification of Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG), Mycoplasma genitalium (MG), and Trichomonas vaginalis (TV) run on the fully automated Alinity m platform. Methods This international, multicenter study evaluated the accuracy, reproducibility, and clinical performance of the Alinity m STI assay compared to commonly used STI assays in a large series of patient samples encountered in clinical practice. Results The Alinity m STI assay identified accurately and precisely single and mixed pathogens from an analytical panel of specimens. The Alinity m STI assay demonstrated high overall agreement rates with comparator STI assays (99.6% for CT [n=2,127], 99.2% for NG [n=2,160], 97.1% for MG [n=491], and 99.4% for TV [n=313]). Conclusions The newly developed Alinity m STI assay accurately detects the 4 sexually transmitted target pathogens in various collection devices across clinically relevant specimen types, regardless of single or mixed infection status

    Wide-Scale Analysis of Human Functional Transcription Factor Binding Reveals a Strong Bias towards the Transcription Start Site

    Get PDF
    We introduce a novel method to screen the promoters of a set of genes with shared biological function, against a precompiled library of motifs, and find those motifs which are statistically over-represented in the gene set. The gene sets were obtained from the functional Gene Ontology (GO) classification; for each set and motif we optimized the sequence similarity score threshold, independently for every location window (measured with respect to the TSS), taking into account the location dependent nucleotide heterogeneity along the promoters of the target genes. We performed a high throughput analysis, searching the promoters (from 200bp downstream to 1000bp upstream the TSS), of more than 8000 human and 23,000 mouse genes, for 134 functional Gene Ontology classes and for 412 known DNA motifs. When combined with binding site and location conservation between human and mouse, the method identifies with high probability functional binding sites that regulate groups of biologically related genes. We found many location-sensitive functional binding events and showed that they clustered close to the TSS. Our method and findings were put to several experimental tests. By allowing a "flexible" threshold and combining our functional class and location specific search method with conservation between human and mouse, we are able to identify reliably functional TF binding sites. This is an essential step towards constructing regulatory networks and elucidating the design principles that govern transcriptional regulation of expression. The promoter region proximal to the TSS appears to be of central importance for regulation of transcription in human and mouse, just as it is in bacteria and yeast.Comment: 31 pages, including Supplementary Information and figure

    Improved molecular laboratory productivity by consolidation of testing on the new random-access analyzer Alinity m

    Get PDF
    Abstract Objectives Automated molecular analyzers have accelerated diagnosis, allowing earlier intervention and better patient follow-up. A recently developed completely automated molecular analyzer, Alinity™ m (Abbott), offers consolidated, continuous, and random-access testing that may improve molecular laboratory workflow. Methods An international, multicenter study compared laboratory workflow metrics across various routine analyzers and Alinity m utilizing assays for human immunodeficiency virus type 1 (HIV-1), hepatitis C virus (HCV), hepatitis B virus (HBV), high-risk human papillomavirus (HR HPV), and sexually transmitted infection (STI) (Chlamydia trachomatis [CT]/Neisseria gonorrhoeae [NG]/Trichomonas vaginalis [TV]/Mycoplasma genitalium [MG]). Three turnaround times (TATs) were assessed: total TAT (sample arrival to result), sample onboard TAT (sample loading and test starting to result), and processing TAT (sample aspiration to result). Results Total TAT was reduced from days with routine analyzers to hours with Alinity m, independent of requested assays. Sample onboard TATs for standard workflow using routine analyzers ranged from 7 to 32.5 h compared to 2.75–6 h for Alinity m. The mean sample onboard TAT for STAT samples on Alinity m was 2.36 h (±0.19 h). Processing TATs for Alinity m were independent of the combination of assays, with 100% of results reported within 117 min. Conclusions The consolidated, continuous, random-access workflow of Alinity m reduces TATs across various assays and is expected to improve both laboratory operational efficiency and patient care

    Multicenter clinical comparative evaluation of Alinity m HIV-1 assay performance.

    Get PDF
    Abstract Background Accurate, rapid detection of HIV-1 RNA is critical for early diagnosis, treatment decision making, and long-term management of HIV-1 infection. Objective We evaluated the diagnostic performance of the Alinity m HIV-1 assay, which uses a dual target/dual probe design against highly conserved target regions of the HIV-1 genome and is run on the fully automated Alinity m platform. Study design This was an international, multisite study that compared the diagnostic performance of the Alinity m HIV-1 assay to four commercially available HIV-1 assays routinely used in nine independent clinical laboratories. Alinity m HIV-1 assay precision, detectability, and reproducibility was compared across four study sites. Results The Alinity m HIV-1 assay produced comparable results to currently available HIV-1 assays (correlation coefficient >0.995), with an overall bias of -0.1 to 0.10 Log10 copies/mL. The Alinity m HIV-1 assay and its predecessor m2000 HIV-1 assay demonstrated comparable detection of 16 different HIV-1 subtypes (R2 = 0.956). A high level of agreement (>88 %) between all HIV-1 assays was seen near clinical decision points of 1.7 Log10 copies/mL (50 copies/mL) and 2.0 Log10 copies/mL (200 copies/mL). Alinity m HIV-1 assay precision was 0.08 and 0.21 Log10 copies/mL at VLs of 1000 and 50 copies/mL, respectively, with a high level of detectability (≥97 % hit rate) and reproducibility across sites. Conclusions The Alinity m HIV-1 assay provides comparable diagnostic accuracy to current HIV-1 assays, and when run on the Alinity m system, has the capacity to shorten the time between diagnosis and treatment

    A molten salt test loop for component and instrumentation testing

    Get PDF
    Molten salt is an effective coolant for a wide range of applications, including nuclear reactors, concentrated solar power, and other high temperature industrial heat transfer processes. The technical readiness level of components and instrumentation for high-temperature molten salt applications needs improvement for molten salt to be more widely adopted. A molten salt test loop was designed, built, and commissioned as a test bed to address these issues. The molten salt test loop at Abilene Christian University was built out of 316 stainless steel with a forced flow centrifugal-type pump, and was instrumented for remote operation. A low-temperature molten nitrate salt was used in this system, which was designed to operate at temperatures up to 300 ◦C and flow rates up to 90 liters per minute. This paper describes the loop design, computational fluid dynamics modeling, construction, and commissioning details. An outline of the data acquisition and control systems is presented. Salt samples were taken before and after introduction into the loop, and melting points were measured both before and after salt circulation. Performance of the system is discussed as well as improvements required for higher temperature loops envisioned for the future

    Controls on the barium isotope compositions of marine sediments

    Get PDF
    The accumulation of barium (Ba) in marine sediments is considered to be a robust proxy for export production, although this application can be limited by uncertainty in BaSO4 preservation and sediment mass accumulation rates. The Ba isotope compositions of marine sediments could potentially record insights into past changes in the marine Ba cycle, which should be insensitive to these limitations, enabling more robust interpretation of sedimentary Ba as a proxy. To investigate the controls on the Ba isotope compositions of marine sediments and their potential for paleo-oceanographic applications, we present the first Ba isotope compositions results for sediments, as well as overlying seawater depth profiles collected in the South Atlantic. Variations in Ba isotope compositions of the sediments predominantly reflect changes in the relative contributions of detrital and authigenic Ba sources, with open-ocean sediments constraining the isotope composition of authigenic Ba to be 138/134 Ba ≈ +0.1 ‰. This value is consistent with the average isotope composition inferred for sinking particulate Ba using simple mass balance models of Ba in the overlying water column and is hypothesized to reflect the removal of Ba from the upper water column with an associated isotopic fractionation of Δ 138/134 Ba diss - part ≈ +0.4 to +0.5. Perturbations to upper ocean Ba cycling, due to changes in export production and the supply of Ba via upwelling, should therefore be recorded by the isotope compositions of sedimentary authigenic Ba. Such insights will help to improve the reliable application of Ba accumulation rates in marine sediments as a proxy for past changes in export production

    Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries.

    Get PDF
    BACKGROUND: As global initiatives increase patient access to surgical treatments, there remains a need to understand the adverse effects of surgery and define appropriate levels of perioperative care. METHODS: We designed a prospective international 7-day cohort study of outcomes following elective adult inpatient surgery in 27 countries. The primary outcome was in-hospital complications. Secondary outcomes were death following a complication (failure to rescue) and death in hospital. Process measures were admission to critical care immediately after surgery or to treat a complication and duration of hospital stay. A single definition of critical care was used for all countries. RESULTS: A total of 474 hospitals in 19 high-, 7 middle- and 1 low-income country were included in the primary analysis. Data included 44 814 patients with a median hospital stay of 4 (range 2-7) days. A total of 7508 patients (16.8%) developed one or more postoperative complication and 207 died (0.5%). The overall mortality among patients who developed complications was 2.8%. Mortality following complications ranged from 2.4% for pulmonary embolism to 43.9% for cardiac arrest. A total of 4360 (9.7%) patients were admitted to a critical care unit as routine immediately after surgery, of whom 2198 (50.4%) developed a complication, with 105 (2.4%) deaths. A total of 1233 patients (16.4%) were admitted to a critical care unit to treat complications, with 119 (9.7%) deaths. Despite lower baseline risk, outcomes were similar in low- and middle-income compared with high-income countries. CONCLUSIONS: Poor patient outcomes are common after inpatient surgery. Global initiatives to increase access to surgical treatments should also address the need for safe perioperative care. STUDY REGISTRATION: ISRCTN5181700
    corecore