23 research outputs found
Recommended from our members
FloatingCanvas: quantification of 3D retinal structures from spectral-domain optical coherence tomography
Spectral-domain optical coherence tomography (SD-OCT) provides volumetric images of retinal structures with unprecedented detail. Accurate segmentation algorithms and feature quantification in these images, however, are needed to realize the full potential of SD-OCT. The fully automated segmentation algorithm, FloatingCanvas, serves this purpose and performs a volumetric segmentation of retinal tissue layers in three-dimensional image volume acquired around the optic nerve head without requiring any pre-processing. The reconstructed layers are analysed to extract features such as blood vessels and retinal nerve fibre layer thickness. Findings from images obtained with the RTVue-100 SD-OCT (Optovue, Fremont, CA, USA) indicate that FloatingCanvas is computationally efficient and is robust to the noise and low contrast in the images. The FloatingCanvas segmentation demonstrated good agreement with the human manual grading. The retinal nerve fibre layer thickness maps obtained with this method are clinically realistic and highly reproducible compared with time-domain StratusOCT™
Automated choroidal segmentation of 1060 nm OCT in healthy and pathologic eyes using a statistical model
A two stage statistical model based on texture and shape for fully automatic choroidal segmentation of normal and pathologic eyes obtained by a 1060 nm optical coherence tomography (OCT) system is developed. A novel dynamic programming approach is implemented to determine location of the retinal pigment epithelium/ Bruch’s membrane /choriocapillaris (RBC) boundary. The choroid–sclera interface (CSI) is segmented using a statistical model. The algorithm is robust even in presence of speckle noise, low signal (thick choroid), retinal pigment epithelium (RPE) detachments and atrophy, drusen, shadowing and other artifacts. Evaluation against a set of 871 manually segmented cross-sectional scans from 12 eyes achieves an average error rate of 13%, computed per tomogram as a ratio of incorrectly classified pixels and the total layer surface. For the first time a fully automatic choroidal segmentation algorithm is successfully applied to a wide range of clinical volumetric OCT data
Wavelet denoising of multiframe optical coherence tomography data
We introduce a novel speckle noise reduction algorithm for OCT images. Contrary to present approaches, the algorithm does not rely on simple averaging of multiple image frames or denoising on the final averaged image. Instead it uses wavelet decompositions of the single frames for a local noise and structure estimation. Based on this analysis, the wavelet detail coefficients are weighted, averaged and reconstructed. At a signal-to-noise gain at about 100% we observe only a minor sharpness decrease, as measured by a full-width-half-maximum reduction of 10.5%. While a similar signal-to-noise gain would require averaging of 29 frames, we achieve this result using only 8 frames as input to the algorithm. A possible application of the proposed algorithm is preprocessing in retinal structure segmentation algorithms, to allow a better differentiation between real tissue information and unwanted speckle noise
Active Contours and Image Segmentation: The Current State Of the Art
Image segmentation is a fundamental task in image analysis responsible for partitioning an image into multiple sub-regions based on a desired feature. Active contours have been widely used as attractive image segmentation methods because they always produce sub-regions with continuous boundaries, while the kernel-based edge detection methods, e.g. Sobel edge detectors, often produce discontinuous boundaries. The use of level set theory has provided more flexibility and convenience in the implementation of active contours. However, traditional edge-based active contour models have been applicable to only relatively simple images whose sub-regions are uniform without internal edges. Here in this paper we attempt to brief the taxonomy and current state of the art in Image segmentation and usage of Active Contours
Robust segmentation of intraretinal layers in the normal human fovea using a novel statistical model based on texture and shape analysis
A novel statistical model based on texture and shape for fully automatic intraretinal layer segmentation of normal retinal tomograms obtained by a commercial 800nm optical coherence tomography (OCT) system is developed. While existing algorithms often fail dramatically due to strong speckle noise, non-optimal imaging conditions, shadows and other artefacts, the novel algorithm’s accuracy only slowly deteriorates when progressively increasing segmentation task difficulty. Evaluation against a large set of manual segmentations shows unprecedented robustness, even in the presence of additional strong speckle noise, with dynamic range tested down to 12dB, enabling segmentation of almost all intraretinal layers in cases previously inaccessible to the existing algorithms. For the first time, an error measure is computed from a large, representative manually segmented data set (466 B-scans from 17 eyes, segmented twice by different operators) and compared to the automatic segmentation with a difference of only 2.6% against the inter-observer variability
Retinal Nerve Fiber Layer Segmentation on FD-OCT Scans of Normal Subjects and Glaucoma Patients
Automated measurements of the retinal nerve fiber layer thickness on circular OCT B-Scans provide physicians additional parameters for glaucoma diagnosis. We propose a novel retinal nerve fiber layer segmentation algorithm for frequency domain data that can be applied on scans from both normal healthy subjects, as well as glaucoma patients, using the same set of parameters. In addition, the algorithm remains almost unaffected by image quality. The main part of the segmentation process is based on the minimization of an energy function consisting of gradient and local smoothing terms. A quantitative evaluation comparing the automated segmentation results to manually corrected segmentations from three reviewers is performed. A total of 72 scans from glaucoma patients and 132 scans from normal subjects, all from different persons, composed the database for the evaluation of the segmentation algorithm. A mean absolute error per A-Scan of 2.9 µm was achieved on glaucomatous eyes, and 3.6 µm on healthy eyes. The mean absolute segmentation error over all A-Scans lies below 10 µm on 95.1% of the images. Thus our approach provides a reliable tool for extracting diagnostic relevant parameters from OCT B-Scans for glaucoma diagnosis