440 research outputs found

    Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions

    Tracking and Mapping in Medical Computer Vision: A Review

    Full text link
    As computer vision algorithms are becoming more capable, their applications in clinical systems will become more pervasive. These applications include diagnostics such as colonoscopy and bronchoscopy, guiding biopsies and minimally invasive interventions and surgery, automating instrument motion and providing image guidance using pre-operative scans. Many of these applications depend on the specific visual nature of medical scenes and require designing and applying algorithms to perform in this environment. In this review, we provide an update to the field of camera-based tracking and scene mapping in surgery and diagnostics in medical computer vision. We begin with describing our review process, which results in a final list of 515 papers that we cover. We then give a high-level summary of the state of the art and provide relevant background for those who need tracking and mapping for their clinical applications. We then review datasets provided in the field and the clinical needs therein. Then, we delve in depth into the algorithmic side, and summarize recent developments, which should be especially useful for algorithm designers and to those looking to understand the capability of off-the-shelf methods. We focus on algorithms for deformable environments while also reviewing the essential building blocks in rigid tracking and mapping since there is a large amount of crossover in methods. Finally, we discuss the current state of the tracking and mapping methods along with needs for future algorithms, needs for quantification, and the viability of clinical applications in the field. We conclude that new methods need to be designed or combined to support clinical applications in deformable environments, and more focus needs to be put into collecting datasets for training and evaluation.Comment: 31 pages, 17 figure

    Autonomous Tissue Scanning under Free-Form Motion for Intraoperative Tissue Characterisation

    Full text link
    In Minimally Invasive Surgery (MIS), tissue scanning with imaging probes is required for subsurface visualisation to characterise the state of the tissue. However, scanning of large tissue surfaces in the presence of deformation is a challenging task for the surgeon. Recently, robot-assisted local tissue scanning has been investigated for motion stabilisation of imaging probes to facilitate the capturing of good quality images and reduce the surgeon's cognitive load. Nonetheless, these approaches require the tissue surface to be static or deform with periodic motion. To eliminate these assumptions, we propose a visual servoing framework for autonomous tissue scanning, able to deal with free-form tissue deformation. The 3D structure of the surgical scene is recovered and a feature-based method is proposed to estimate the motion of the tissue in real-time. A desired scanning trajectory is manually defined on a reference frame and continuously updated using projective geometry to follow the tissue motion and control the movement of the robotic arm. The advantage of the proposed method is that it does not require the learning of the tissue motion prior to scanning and can deal with free-form deformation. We deployed this framework on the da Vinci surgical robot using the da Vinci Research Kit (dVRK) for Ultrasound tissue scanning. Since the framework does not rely on information from the Ultrasound data, it can be easily extended to other probe-based imaging modalities.Comment: 7 pages, 5 figures, ICRA 202

    Medical SLAM in an autonomous robotic system

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-operative morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilities by observing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted instruments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This thesis addresses the ambitious goal of achieving surgical autonomy, through the study of the anatomical environment by Initially studying the technology present and what is needed to analyze the scene: vision sensors. A novel endoscope for autonomous surgical task execution is presented in the first part of this thesis. Which combines a standard stereo camera with a depth sensor. This solution introduces several key advantages, such as the possibility of reconstructing the 3D at a greater distance than traditional endoscopes. Then the problem of hand-eye calibration is tackled, which unites the vision system and the robot in a single reference system. Increasing the accuracy in the surgical work plan. In the second part of the thesis the problem of the 3D reconstruction and the algorithms currently in use were addressed. In MIS, simultaneous localization and mapping (SLAM) can be used to localize the pose of the endoscopic camera and build ta 3D model of the tissue surface. Another key element for MIS is to have real-time knowledge of the pose of surgical tools with respect to the surgical camera and underlying anatomy. Starting from the ORB-SLAM algorithm we have modified the architecture to make it usable in an anatomical environment by adding the registration of the pre-operative information of the intervention to the map obtained from the SLAM. Once it has been proven that the slam algorithm is usable in an anatomical environment, it has been improved by adding semantic segmentation to be able to distinguish dynamic features from static ones. All the results in this thesis are validated on training setups, which mimics some of the challenges of real surgery and on setups that simulate the human body within Autonomous Robotic Surgery (ARS) and Smart Autonomous Robotic Assistant Surgeon (SARAS) projects

    Medical SLAM in an autonomous robotic system

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-operative morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilities by observing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted instruments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This thesis addresses the ambitious goal of achieving surgical autonomy, through the study of the anatomical environment by Initially studying the technology present and what is needed to analyze the scene: vision sensors. A novel endoscope for autonomous surgical task execution is presented in the first part of this thesis. Which combines a standard stereo camera with a depth sensor. This solution introduces several key advantages, such as the possibility of reconstructing the 3D at a greater distance than traditional endoscopes. Then the problem of hand-eye calibration is tackled, which unites the vision system and the robot in a single reference system. Increasing the accuracy in the surgical work plan. In the second part of the thesis the problem of the 3D reconstruction and the algorithms currently in use were addressed. In MIS, simultaneous localization and mapping (SLAM) can be used to localize the pose of the endoscopic camera and build ta 3D model of the tissue surface. Another key element for MIS is to have real-time knowledge of the pose of surgical tools with respect to the surgical camera and underlying anatomy. Starting from the ORB-SLAM algorithm we have modified the architecture to make it usable in an anatomical environment by adding the registration of the pre-operative information of the intervention to the map obtained from the SLAM. Once it has been proven that the slam algorithm is usable in an anatomical environment, it has been improved by adding semantic segmentation to be able to distinguish dynamic features from static ones. All the results in this thesis are validated on training setups, which mimics some of the challenges of real surgery and on setups that simulate the human body within Autonomous Robotic Surgery (ARS) and Smart Autonomous Robotic Assistant Surgeon (SARAS) projects

    Computational Multispectral Endoscopy

    Get PDF
    Minimal Access Surgery (MAS) is increasingly regarded as the de-facto approach in interventional medicine for conducting many procedures this is due to the reduced patient trauma and consequently reduced recovery times, complications and costs. However, there are many challenges in MAS that come as a result of viewing the surgical site through an endoscope and interacting with tissue remotely via tools, such as lack of haptic feedback; limited field of view; and variation in imaging hardware. As such, it is important best utilise the imaging data available to provide a clinician with rich data corresponding to the surgical site. Measuring tissue haemoglobin concentrations can give vital information, such as perfusion assessment after transplantation; visualisation of the health of blood supply to organ; and to detect ischaemia. In the area of transplant and bypass procedures measurements of the tissue tissue perfusion/total haemoglobin (THb) and oxygen saturation (SO2) are used as indicators of organ viability, these measurements are often acquired at multiple discrete points across the tissue using with a specialist probe. To acquire measurements across the whole surface of an organ one can use a specialist camera to perform multispectral imaging (MSI), which optically acquires sequential spectrally band limited images of the same scene. This data can be processed to provide maps of the THb and SO2 variation across the tissue surface which could be useful for intra operative evaluation. When capturing MSI data, a trade off often has to be made between spectral sensitivity and capture speed. The work in thesis first explores post processing blurry MSI data from long exposure imaging devices. It is of interest to be able to use these MSI data because the large number of spectral bands that can be captured, the long capture times, however, limit the potential real time uses for clinicians. Recognising the importance to clinicians of real-time data, the main body of this thesis develops methods around estimating oxy- and deoxy-haemoglobin concentrations in tissue using only monocular and stereo RGB imaging data

    Visual SLAM for Measurement and Augmented Reality in Laparoscopic Surgery

    Get PDF
    In spite of the great advances in laparoscopic surgery, this type of surgery still shows some difficulties during its realization, mainly caused by its complex maneuvers and, above all, by the loss of the depth perception. Unlike classical open surgery --laparotomy-- where surgeons have direct contact with organs and a complete 3D perception, laparoscopy is carried out by means of specialized instruments, and a monocular camera (laparoscope) in which the 3D scene is projected into a 2D plane --image. The main goal of this thesis is to face with this loss of depth perception by making use of Simultaneous Localization and Mapping (SLAM) algorithms developed in the fields of robotics and computer vision during the last years. These algorithms allow to localize, in real time (25 \thicksim 30 frames per second), a camera that moves freely inside an unknown rigid environment while, at the same time, they build a map of this environment by exploiting images gathered by that camera. These algorithms have been extensively validated both in man-made environments (buildings, rooms, ...) and in outdoor environments, showing robustness to occlusions, sudden camera motions, or clutter. This thesis tries to extend the use of these algorithms to laparoscopic surgery. Due to the intrinsic nature of internal body images (they suffer from deformations, specularities, variable illumination conditions, limited movements, ...), applying this type of algorithms to laparoscopy supposes a real challenge. Knowing the camera (laparoscope) location with respect to the scene (abdominal cavity) and the 3D map of that scene opens new interesting possibilities inside the surgical field. This knowledge enables to do augmented reality annotations directly on the laparoscopic images (e.g. alignment of preoperative 3D CT models); intracavity 3D distance measurements; or photorealistic 3D reconstructions of the abdominal cavity recovering synthetically the lost depth. These new facilities provide security and rapidity to surgical procedures without disturbing the classical procedure workflow. Hence, these tools are available inside the surgeon's armory, being the surgeon who decides to use them or not. Additionally, knowledge of the camera location with respect to the patient's abdominal cavity is fundamental for future development of robots that can operate automatically since, knowing this location, the robot will be able to localize other tools controlled by itself with respect to the patient. In detail, the contributions of this thesis are: - To demonstrate the feasibility of applying SLAM algorithms to laparoscopy showing experimentally that using robust data association is a must. - To robustify one of these algorithms, in particular the monocular EKF-SLAM algorithm, by adapting a relocalization system and improving data association with a robust matching algorithm. - To develop of a robust matching method (1-Point RANSAC algorithm). - To develop a new surgical procedure to ease the use of visual SLAM in laparoscopy. - To make an extensive validation of the robust EKF-SLAM (EKF + relocalization + 1-Point RANSAC) obtaining millimetric errors and working in real time both on simulation and real human surgeries. The selected surgery has been the ventral hernia repair. - To demonstrate the potential of these algorithms in laparoscopy: they recover synthetically the depth of the operative field which is lost by using monocular laparoscopes, enable the insertion of augmented reality annotations, and allow to perform distance measurements using only a laparoscopic tool (to define the real scale) and laparoscopic images. - To make a clinical validation showing that these algorithms allow to shorten surgical times of operations and provide more security to the surgical procedures

    On-the-fly dense 3D surface reconstruction for geometry-aware augmented reality.

    Get PDF
    Augmented Reality (AR) is an emerging technology that makes seamless connections between virtual space and the real world by superimposing computer-generated information onto the real-world environment. AR can provide additional information in a more intuitive and natural way than any other information-delivery method that a human has ever in- vented. Camera tracking is the enabling technology for AR and has been well studied for the last few decades. Apart from the tracking problems, sensing and perception of the surrounding environment are also very important and challenging problems. Although there are existing hardware solutions such as Microsoft Kinect and HoloLens that can sense and build the environmental structure, they are either too bulky or too expensive for AR. In this thesis, the challenging real-time dense 3D surface reconstruction technologies are studied and reformulated for the reinvention of basic position-aware AR towards geometry-aware and the outlook of context- aware AR. We initially propose to reconstruct the dense environmental surface using the sparse point from Simultaneous Localisation and Map- ping (SLAM), but this approach is prone to fail in challenging Minimally Invasive Surgery (MIS) scenes such as the presence of deformation and surgical smoke. We subsequently adopt stereo vision with SLAM for more accurate and robust results. With the success of deep learning technology in recent years, we present learning based single image re- construction and achieve the state-of-the-art results. Moreover, we pro- posed context-aware AR, one step further from purely geometry-aware AR towards the high-level conceptual interaction modelling in complex AR environment for enhanced user experience. Finally, a learning-based smoke removal method is proposed to ensure an accurate and robust reconstruction under extreme conditions such as the presence of surgical smoke

    Exploiting Temporal Image Information in Minimally Invasive Surgery

    Get PDF
    Minimally invasive procedures rely on medical imaging instead of the surgeons direct vision. While preoperative images can be used for surgical planning and navigation, once the surgeon arrives at the target site real-time intraoperative imaging is needed. However, acquiring and interpreting these images can be challenging and much of the rich temporal information present in these images is not visible. The goal of this thesis is to improve image guidance for minimally invasive surgery in two main areas. First, by showing how high-quality ultrasound video can be obtained by integrating an ultrasound transducer directly into delivery devices for beating heart valve surgery. Secondly, by extracting hidden temporal information through video processing methods to help the surgeon localize important anatomical structures. Prototypes of delivery tools, with integrated ultrasound imaging, were developed for both transcatheter aortic valve implantation and mitral valve repair. These tools provided an on-site view that shows the tool-tissue interactions during valve repair. Additionally, augmented reality environments were used to add more anatomical context that aids in navigation and in interpreting the on-site video. Other procedures can be improved by extracting hidden temporal information from the intraoperative video. In ultrasound guided epidural injections, dural pulsation provides a cue in finding a clear trajectory to the epidural space. By processing the video using extended Kalman filtering, subtle pulsations were automatically detected and visualized in real-time. A statistical framework for analyzing periodicity was developed based on dynamic linear modelling. In addition to detecting dural pulsation in lumbar spine ultrasound, this approach was used to image tissue perfusion in natural video and generate ventilation maps from free-breathing magnetic resonance imaging. A second statistical method, based on spectral analysis of pixel intensity values, allowed blood flow to be detected directly from high-frequency B-mode ultrasound video. Finally, pulsatile cues in endoscopic video were enhanced through Eulerian video magnification to help localize critical vasculature. This approach shows particular promise in identifying the basilar artery in endoscopic third ventriculostomy and the prostatic artery in nerve-sparing prostatectomy. A real-time implementation was developed which processed full-resolution stereoscopic video on the da Vinci Surgical System

    Change blindness: eradication of gestalt strategies

    Get PDF
    Arrays of eight, texture-defined rectangles were used as stimuli in a one-shot change blindness (CB) task where there was a 50% chance that one rectangle would change orientation between two successive presentations separated by an interval. CB was eliminated by cueing the target rectangle in the first stimulus, reduced by cueing in the interval and unaffected by cueing in the second presentation. This supports the idea that a representation was formed that persisted through the interval before being 'overwritten' by the second presentation (Landman et al, 2003 Vision Research 43149–164]. Another possibility is that participants used some kind of grouping or Gestalt strategy. To test this we changed the spatial position of the rectangles in the second presentation by shifting them along imaginary spokes (by ±1 degree) emanating from the central fixation point. There was no significant difference seen in performance between this and the standard task [F(1,4)=2.565, p=0.185]. This may suggest two things: (i) Gestalt grouping is not used as a strategy in these tasks, and (ii) it gives further weight to the argument that objects may be stored and retrieved from a pre-attentional store during this task
    corecore