30,683 research outputs found

    Integration of multimodal data based on surface registration

    Get PDF
    The paper proposes and evaluates a strategy for the alignment of anatomical and functional data of the brain. The method takes as an input two different sets of images of a same patient: MR data and SPECT. It proceeds in four steps: first, it constructs two voxel models from the two image sets; next, it extracts from the two voxel models the surfaces of regions of interest; in the third step, the surfaces are interactively aligned by corresponding pairs; finally a unique volume model is constructed by selectively applying the geometrical transformations associated to the regions and weighting their contributions. The main advantages of this strategy are (i) that it can be applied retrospectively, (ii) that it is tri-dimensional, and (iii) that it is local. Its main disadvantage with regard to previously published methods it that it requires the extraction of surfaces. However, this step is often required for other stages of the multimodal analysis such as the visualization and therefore its cost can be accounted in the global cost of the process.Postprint (published version

    Image database system for glaucoma diagnosis support

    Get PDF
    Tato práce popisuje přehled standardních a pokročilých metod používaných k diagnose glaukomu v ranném stádiu. Na základě teoretických poznatků je implementován internetově orientovaný informační systém pro oční lékaře, který má tři hlavní cíle. Prvním cílem je možnost sdílení osobních dat konkrétního pacienta bez nutnosti posílat tato data internetem. Druhým cílem je vytvořit účet pacienta založený na kompletním očním vyšetření. Posledním cílem je aplikovat algoritmus pro registraci intenzitního a barevného fundus obrazu a na jeho základě vytvořit internetově orientovanou tři-dimenzionální vizualizaci optického disku. Tato práce je součásti DAAD spolupráce mezi Ústavem Biomedicínského Inženýrství, Vysokého Učení Technického v Brně, Oční klinikou v Erlangenu a Ústavem Informačních Technologií, Friedrich-Alexander University, Erlangen-Nurnberg.This master thesis describes a conception of standard and advanced eye examination methods used for glaucoma diagnosis in its early stage. According to the theoretical knowledge, a web based information system for ophthalmologists with three main aims is implemented. The first aim is the possibility to share medical data of a concrete patient without sending his personal data through the Internet. The second aim is to create a patient account based on a complete eye examination procedure. The last aim is to improve the HRT diagnostic method with an image registration algorithm for the fundus and intensity images and create an optic nerve head web based 3D visualization. This master thesis is a part of project based on DAAD co-operation between Department of Biomedical Engineering, Brno University of Technology, Eye Clinic in Erlangen and Department of Computer Science, Friedrich-Alexander University, Erlangen-Nurnberg.

    Neuroimaging study designs, computational analyses and data provenance using the LONI pipeline.

    Get PDF
    Modern computational neuroscience employs diverse software tools and multidisciplinary expertise to analyze heterogeneous brain data. The classical problems of gathering meaningful data, fitting specific models, and discovering appropriate analysis and visualization tools give way to a new class of computational challenges--management of large and incongruous data, integration and interoperability of computational resources, and data provenance. We designed, implemented and validated a new paradigm for addressing these challenges in the neuroimaging field. Our solution is based on the LONI Pipeline environment [3], [4], a graphical workflow environment for constructing and executing complex data processing protocols. We developed study-design, database and visual language programming functionalities within the LONI Pipeline that enable the construction of complete, elaborate and robust graphical workflows for analyzing neuroimaging and other data. These workflows facilitate open sharing and communication of data and metadata, concrete processing protocols, result validation, and study replication among different investigators and research groups. The LONI Pipeline features include distributed grid-enabled infrastructure, virtualized execution environment, efficient integration, data provenance, validation and distribution of new computational tools, automated data format conversion, and an intuitive graphical user interface. We demonstrate the new LONI Pipeline features using large scale neuroimaging studies based on data from the International Consortium for Brain Mapping [5] and the Alzheimer's Disease Neuroimaging Initiative [6]. User guides, forums, instructions and downloads of the LONI Pipeline environment are available at http://pipeline.loni.ucla.edu

    Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions

    Neuroconductor: an R platform for medical imaging analysis

    Get PDF
    Neuroconductor (https://neuroconductor.org) is an open-source platform for rapid testing and dissemination of reproducible computational imaging software. The goals of the project are to: (i) provide a centralized repository of R software dedicated to image analysis, (ii) disseminate software updates quickly, (iii) train a large, diverse community of scientists using detailed tutorials and short courses, (iv) increase software quality via automatic and manual quality controls, and (v) promote reproducibility of image data analysis. Based on the programming language R (https://www.r-project.org/), Neuroconductor starts with 51 inter-operable packages that cover multiple areas of imaging including visualization, data processing and storage, and statistical inference. Neuroconductor accepts new R package submissions, which are subject to a formal review and continuous automated testing. We provide a description of the purpose of Neuroconductor and the user and developer experience

    Computer- and robot-assisted Medical Intervention

    Full text link
    Medical robotics includes assistive devices used by the physician in order to make his/her diagnostic or therapeutic practices easier and more efficient. This chapter focuses on such systems. It introduces the general field of Computer-Assisted Medical Interventions, its aims, its different components and describes the place of robots in that context. The evolutions in terms of general design and control paradigms in the development of medical robots are presented and issues specific to that application domain are discussed. A view of existing systems, on-going developments and future trends is given. A case-study is detailed. Other types of robotic help in the medical environment (such as for assisting a handicapped person, for rehabilitation of a patient or for replacement of some damaged/suppressed limbs or organs) are out of the scope of this chapter.Comment: Handbook of Automation, Shimon Nof (Ed.) (2009) 000-00

    Augmented Reality-based Feedback for Technician-in-the-loop C-arm Repositioning

    Full text link
    Interventional C-arm imaging is crucial to percutaneous orthopedic procedures as it enables the surgeon to monitor the progress of surgery on the anatomy level. Minimally invasive interventions require repeated acquisition of X-ray images from different anatomical views to verify tool placement. Achieving and reproducing these views often comes at the cost of increased surgical time and radiation dose to both patient and staff. This work proposes a marker-free "technician-in-the-loop" Augmented Reality (AR) solution for C-arm repositioning. The X-ray technician operating the C-arm interventionally is equipped with a head-mounted display capable of recording desired C-arm poses in 3D via an integrated infrared sensor. For C-arm repositioning to a particular target view, the recorded C-arm pose is restored as a virtual object and visualized in an AR environment, serving as a perceptual reference for the technician. We conduct experiments in a setting simulating orthopedic trauma surgery. Our proof-of-principle findings indicate that the proposed system can decrease the 2.76 X-ray images required per desired view down to zero, suggesting substantial reductions of radiation dose during C-arm repositioning. The proposed AR solution is a first step towards facilitating communication between the surgeon and the surgical staff, improving the quality of surgical image acquisition, and enabling context-aware guidance for surgery rooms of the future. The concept of technician-in-the-loop design will become relevant to various interventions considering the expected advancements of sensing and wearable computing in the near future
    corecore