224 research outputs found

    Front-end electronics for the ALICE TPC-detector

    Get PDF
    The Front-End electronics for the Time Projection Chamber (TPC) for the ALICE experiment consists of 5x105 channels. A single readout channel is comprised of three basic units: a charge sensitive amplifier/shaper with a fast tail cancellation; a 10 bit 10 Msamples/sec low power ADC; a digital ASIC which contains the zero suppression circuit and a multiple-event buffer. Data from a number of channels (4096) are multiplexed into an optical link (DDL) by means of a local custom bus which can support a data throughput of 2 Mbyte/event at a trigger rate of 50 Hz. The construction of a prototype of this electronics is presented in this paper

    Punica granatum (Pomegranate) juice provides an HIV-1 entry inhibitor and candidate topical microbicide

    Get PDF
    BACKGROUND: For ≈ 24 years the AIDS pandemic has claimed ≈ 30 million lives, causing ≈ 14,000 new HIV-1 infections daily worldwide in 2003. About 80% of infections occur by heterosexual transmission. In the absence of vaccines, topical microbicides, expected to block virus transmission, offer hope for controlling the pandemic. Antiretroviral chemotherapeutics have decreased AIDS mortality in industrialized countries, but only minimally in developing countries. To prevent an analogous dichotomy, microbicides should be: acceptable; accessible; affordable; and accelerative in transition from development to marketing. Already marketed pharmaceutical excipients or foods, with established safety records and adequate anti-HIV-1 activity, may provide this option. METHODS: Fruit juices were screened for inhibitory activity against HIV-1 IIIB using CD4 and CXCR4 as cell receptors. The best juice was tested for inhibition of: (1) infection by HIV-1 BaL, utilizing CCR5 as the cellular coreceptor; and (2) binding of gp120 IIIB and gp120 BaL, respectively, to CXCR4 and CCR5. To remove most colored juice components, the adsorption of the effective ingredient(s) to dispersible excipients and other foods was investigated. A selected complex was assayed for inhibition of infection by primary HIV-1 isolates. RESULTS: HIV-1 entry inhibitors from pomegranate juice adsorb onto corn starch. The resulting complex blocks virus binding to CD4 and CXCR4/CCR5 and inhibits infection by primary virus clades A to G and group O. CONCLUSION: These results suggest the possibility of producing an anti-HIV-1 microbicide from inexpensive, widely available sources, whose safety has been established throughout centuries, provided that its quality is adequately standardized and monitored

    Hadron Energy Reconstruction for the ATLAS Calorimetry in the Framework of the Non-parametrical Method

    Get PDF
    This paper discusses hadron energy reconstruction for the ATLAS barrel prototype combined calorimeter (consisting of a lead-liquid argon electromagnetic part and an iron-scintillator hadronic part) in the framework of the non-parametrical method. The non-parametrical method utilizes only the known e/he/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. Thus, this technique lends itself to an easy use in a first level trigger. The reconstructed mean values of the hadron energies are within ±1\pm 1% of the true values and the fractional energy resolution is [(58±3)/E+(2.5±0.3)[(58\pm3)% /\sqrt{E}+(2.5\pm0.3)%]\oplus (1.7\pm0.2)/E. The value of the e/he/h ratio obtained for the electromagnetic compartment of the combined calorimeter is 1.74±0.041.74\pm0.04 and agrees with the prediction that e/h>1.7e/h > 1.7 for this electromagnetic calorimeter. Results of a study of the longitudinal hadronic shower development are also presented. The data have been taken in the H8 beam line of the CERN SPS using pions of energies from 10 to 300 GeV.Comment: 33 pages, 13 figures, Will be published in NIM

    Multi-year interlaboratory exercises for the analysis of illicit drugs and metabolites in wastewater:development of a quality control system

    Get PDF
    Thirty-seven laboratories from 25 countries present the development of an inter-laboratory testing scheme for the analysis of seven illicit drug residues in standard solutions, tap- and wastewater. Almost 10 000 concentration values were evaluated: triplicates of up to five samples and 26 laboratories per year. The setup was substantially improved with experiences gained across the six repetitions (e.g. matrix type, sample conditions, spiking levels). From this, (pre-)analytical issues (e.g. pH adjustment, filtration) were revealed for specific analytes which resulted in formulation of best-practice protocols for inter-laboratory setup and analytical procedures. The results illustrate the effectiveness of the inter-laboratory setup to assess laboratory performance in the framework of wastewater-based epidemiology. The exercise proved that measurements of laboratories were of high quality (>80% satisfactory results for six out of seven analytes) and that analytical follow-up is important to assist laboratories in improving robustness of wastewater-based epidemiology results

    Test beam results of a stereo preshower integrated in the liquid argon accordion calorimeter

    Get PDF
    This paper describes the construction of an integrated preshower within the RD3 liquid argon accordion calorimeter. It has a stereo view which enables the measurement of two transverse coordinates. The prototype was tested at CERN with electrons, photons and muons to validate its capability to work at LHC ( Energy resolution, impact point resolution, angular resolution, πo\pi^o/Îł\gamma rejection )

    Construction and test of a fine-grained liquid argon preshower prototype

    Get PDF
    A separate liquid argon preshower detector consisting of two layers featuring a fine granularity of 2.5~10−3^{\mathrm{-3}} was studied by the RD3 collaboration. A prototype covering approximately 0.8 in pseudo-rapidity and 9 degrees in azimuth was built and tested at CERN in July 94. CMOS and GaAs VLSI preamplifiers were designed and tested for this occasion. The combined response of this detector and an accordion electromagnetic calorimeter prototype to muons, electrons and photons is presented. For minimum ionizing tracks a signal-to-noise ratio of 4.5 per preshower layer was measured. Above 150~GeV the space resolution for electrons is better than 250~ÎŒ\mum in both directions. The precision on the electromagnetic shower direction, determined together with the calorimeter, is better than 4 mrad above 50~GeV. It is concluded that the preshower detector would adequately fulfil its role for future operation at CERN Large Hadron Collider

    Performance of an endcap prototype of the Atlas accordion electromagnetic calorimeter

    Get PDF
    The design and construction of a lead-liquid argon endcap calorimeter prototype using an accordion geometry and conceived as a sector of the inner wheel of the endcap calorimeter of the future ATLAS experiment at the LHC is described. The performance obtained using electron beam data is presented. The main results are an energy resolution with a sampling term below 11%/E(GeV)11\%/\sqrt{E(\rm GeV)} and a small local constant term, a good linearity of the response with the incident energy and a global constant term of 0.8\% over an extended area in the rapidity range of 2.2η2.92.2\eta 2.9. These properties make the design suitable for the ATLAS electromagnetic endcap calorimeter

    Test beam results of a stereo preshower integrated in the liquid argon accordion calorimeter

    Get PDF
    This paper describes the construction of an integrated preshower within the RD3 liquid argon accordion calorimeter. It has a stereo view which enables the measurement of two transverse coordinates. The prototype was tested at CERN with electrons, photons and muons to validate its capability to work at LHC (Energy resolution, impact point resolution, angular resolution, π o Îł rejection). (Elsevier
    • 

    corecore