34 research outputs found

    Effect of tsDCS applied with different electrode configurations on the lumbar spinal circuits

    Get PDF
    Spinal Cord Injury (SCI) is a severe injury to the central nervous system (CNS) which, despite a heavy post injury rehabilitation regime, often leaves patients bound to a wheelchair or with other impairments diminishing their quality of life. Trans-spinal direct current stimulation (tsDCS) is a promising new technique for the treatment of SCI. During tsDCS a small direct current is applied to the spinal cord via two or more stimulation electrodes, placed over the backbone of a subject. The technique aims to alter the response of the neural pathways in the spinal cord, which is hypothesized to have a positive effect on the recovery of the damaged spinal cord neuronal networks. The objective of this study, is to assess how tsDCS modulates the excitability of the spinal cord and whether this modulation is dependent on the electrode placement configurations. The primary goal is to compare a new electrode placement configuration with one that is commonly used in previous tsDCS studies. This is assessed using the H- Reflex, whereby the novel configuration is hypothesized to have a larger modulatory effect on the spinal circuits. The two different configurations are: 1) cathode and anode placed on the T11 vertebra and the left shoulder blade respectively (commonly used) and 2) the two electrodes placed over the spinal cord, 7 centimeters apart and centered around the 11 thoracic vertebra. TsDCS is applied on the lumbar spinal cord for a period of 15 minutes with a current of 2,5mA. The ascending part of the H-reflex recruitment curve is measured before, during and after tsDCS. We hereby present the outcome of the aforementioned study as well as the current progress of our laboratory with respect to the effect of tsDCS on the spinal circuits. We hope that our work will be able to contribute to the effectivity of tsDCS, which could possibly be applied in the rehabilitation of spinal cord injured subjects in the future

    Correction:How the COVID-19 pandemic highlights the necessity of animal research (vol 30, pg R1014, 2020)

    Get PDF
    (Current Biology 30, R1014–R1018; September 21, 2020) As a result of an author oversight in the originally published version of this article, a number of errors were introduced in the author list and affiliations. First, the middle initials were omitted from the names of several authors. Second, the surname of Dr. van Dam was mistakenly written as “Dam.” Third, the first name of author Bernhard Englitz was misspelled as “Bernard” and the surname of author B.J.A. Pollux was misspelled as “Pullox.” Finally, Dr. Keijer's first name was abbreviated rather than written in full. These errors, as well as various errors in the author affiliations, have now been corrected online

    Harnessing demographic differences in organizations:what moderates the effects of workplace diversity?

    Get PDF
    To account for the double-edged nature of demographic workplace diversity (i.e,. relational demography, work group diversity, and organizational diversity) effects on social integration, performance, and well-being related variables, research has moved away from simple main effect approaches and started examining variables that moderate these effects. While there is no shortage of primary studies of the conditions under which diversity leads to positive or negative outcomes, it remains unclear which contingency factors make it work. Using the Categorization-Elaboration Model as our theoretical lens, we review variables moderating the effects of workplace diversity on social integration, performance, and well-being outcomes, focusing on factors that organizations and managers have control over (i.e., strategy, unit design, human resource, leadership, climate/culture, and individual differences). We point out avenues for future research and conclude with practical implications

    Occurrence and Genetic Diversity of Uncultured Legionella spp. in Drinking Water Treated at Temperatures below 15°C

    No full text
    Representatives of the genus Legionella were detected by use of a real-time PCR method in all water samples collected directly after treatment from 16 surface water (SW) supplies prior to postdisinfection and from 81 groundwater (GW) supplies. Legionella concentrations ranged from 1.1 × 10(3) to 7.8 × 10(5) cells liter(−1) and were significantly higher in SW treated with multiple barriers at 4°C than in GW treated at 9 to 12°C with aeration and filtration but without chemical disinfection. No Legionellae (<50 CFU liter(−1)) were detected in treated water by the culture method. Legionella was also observed in untreated SW and in untreated aerobic and anaerobic GW. Filtration processes in SW and GW treatment had little effect or increased the Legionella concentration, but ozonation in SW treatment caused about 1-log-unit reduction. A phylogenetic analysis of 16S rRNA gene sequences of 202 clones, obtained from a selection of samples, showed a high similarity (>91%) with Legionella sequences in the GenBank database. A total of 40 (33%) of the 16S rRNA gene sequences obtained from treated water were identified as described Legionella species and types, including L. bozemanii, L. worsleiensis, Legionella-like amoebal pathogen types, L. quateirensis, L. waltersii, and L. pneumophila. 16S rRNA gene sequences with a similarity of below 97% from described species were positioned all over the phylogenetic tree of Legionella. Hence, a large diversity of yet-uncultured Legionellae are common members of the microbial communities in SW and GW treated at water temperatures of below 15°C

    Concentration and Diversity of Uncultured Legionella spp. in Two Unchlorinated Drinking Water Supplies with Different Concentrations of Natural Organic Matter ▿ †

    No full text
    Two unchlorinated drinking water supplies were investigated to assess the potential of water treatment and distribution systems to support the growth of Legionella spp. The treatment plant for supply A distributed treated groundwater with a low concentration (<0.5 ppm of C) of natural organic matter (NOM), and the treatment plant for supply B distributed treated groundwater with a high NOM concentration (8 ppm of C). In both supplies, the water temperature ranged from about 10°C after treatment to 18°C during distribution. The concentrations of Legionella spp. in distributed water, analyzed with quantitative PCR (Q-PCR), averaged 2.9 (± 1.9) × 102 cells liter−1 in supply A and 2.5 (± 1.6) × 103 cells liter−1 in supply B. No Legionella was observed with the culture method. A total of 346 clones (96 operational taxonomical units [OTUs] with ≥97% sequence similarity) were retrieved from water and biofilms of supply A and 251 (43 OTUs) from supply B. The estimation of the average value of total species richness (Chao1) in supply A (153) was clearly higher than that for supply B (58). In each supply, about 77% of the sequences showed <97% similarity to described species. Sequences related to L. pneumophila were only incidentally observed. The Legionella populations of the two supplies are divided into two distinct clusters based on distances in the phylogenetic tree as fractions of the branch length. Thus, a large variety of mostly yet-undescribed Legionella spp. proliferates in unchlorinated water supplies at temperatures below 18°C. The lowest concentration and greatest diversity were observed in the supply with the low NOM concentration

    Changes in H-Reflex Recruitment After Trans-Spinal Direct Current Stimulation With Multiple Electrode Configurations

    No full text
    Trans-spinal direct current stimulation (tsDCS) is an electro-modulatory tool with possible application in the rehabilitation of spinal cord injury. TsDCS generates a small electric field, aiming to induce lasting, functional neuromodulation in the targeted neuronal networks. Earlier studies have shown significant modulatory effects after application of lumbar tsDCS. However, for clinical application, a better understanding of application specific factors is required. Our goal was to investigate the effect of different electrode configurations using lumbar spinal tsDCS on spinal excitability. We applied tsDCS (2.5 mA, 15 min) in 10 healthy subjects with three different electrode configurations: (1) Anode and cathode placed over vertebra T11, and the posterior left shoulder respectively (LSC-S) (one polarity), and (2) Both electrodes placed in equal distance (ED) (7 cm) above and below vertebra T11, investigated for two polarities (ED-Anodal/Cathodal). The soleus H-Reflex is measured before, during and after tsDCS in either electrode configuration or a sham condition. To account for genetic predispositions in response to direct current stimulation, subject BDNF genotype was assessed. Stimulation in configuration ED-Cathodal induced an amplitude reduction of the H-reflex, 30 min after tsDCS with respect to baseline, whereas none of the other configurations led to significant post intervention effects. BDNF genotype did not correlate with post intervention effects. Furthermore, we failed to replicate effects shown by a previous study, which highlights the need for a better understanding of methodological and subject specific influences on tsDCS outcome. The H-reflex depression after tsDCS (Config. ED-Cathodal) provides new insights and may foster our understanding of the working mechanism of tsDCS

    Detection of Protozoan Hosts for Legionella pneumophila in Engineered Water Systems by Using a Biofilm Batch Test▿ †

    Get PDF
    Legionella pneumophila proliferates in aquatic habitats within free-living protozoa, 17 species of which have been identified as hosts by using in vitro experiments. The present study aimed at identifying protozoan hosts for L. pneumophila by using a biofilm batch test (BBT). Samples (600 ml) collected from 21 engineered freshwater systems, with added polyethylene cylinders to promote biofilm formation, were inoculated with L. pneumophila and subsequently incubated at 37°C for 20 days. Growth of L. pneumophila was observed in 16 of 18 water types when the host protozoan Hartmannella vermiformis was added. Twelve of the tested water types supported growth of L. pneumophila or indigenous Legionella anisa without added H. vermiformis. In 12 of 19 BBT flasks H. vermiformis was indicated as a host, based on the ratio between maximum concentrations of L. pneumophila and H. vermiformis, determined with quantitative PCR (Q-PCR), and the composition of clone libraries of partial 18S rRNA gene fragments. Analyses of 609 eukaryotic clones from the BBTs revealed that 68 operational taxonomic units (OTUs) showed the highest similarity to free-living protozoa. Forty percent of the sequences clustering with protozoa showed ≥99.5% similarity to H. vermiformis. None of the other protozoa serving as hosts in in vitro studies were detected in the BBTs. In several tests with growth of L. pneumophila, the protozoa Diphylleia rotans, Echinamoeba thermarum, and Neoparamoeba sp. were identified as candidate hosts. In vitro studies are needed to confirm their role as hosts for L. pneumophila. Unidentified protozoa were implicated as hosts for uncultured Legionella spp. grown in BBT flasks at 15°C

    Ammonia-Oxidizing Bacteria and Archaea in Groundwater Treatment and Drinking Water Distribution Systems▿ †

    No full text
    The ammonia-oxidizing prokaryote (AOP) community in three groundwater treatment plants and connected distribution systems was analyzed by quantitative real-time PCR and sequence analysis targeting the amoA gene of ammonia-oxidizing bacteria (AOB) and archaea (AOA). Results demonstrated that AOB and AOA numbers increased during biological filtration of ammonia-rich anoxic groundwater, and AOP were responsible for ammonium removal during treatment. In one of the treatment trains at plant C, ammonia removal correlated significantly with AOA numbers but not with AOB numbers. Thus, AOA were responsible for ammonia removal in water treatment at one of the studied plants. Furthermore, an observed negative correlation between the dissolved organic carbon (DOC) concentration in the water and AOA numbers suggests that high DOC levels might reduce growth of AOA. AOP entered the distribution system in numbers ranging from 1.5 × 103 to 6.5 × 104 AOPs ml−1. These numbers did not change during transport in the distribution system despite the absence of a disinfectant residual. Thus, inactive AOP biomass does not seem to be degraded by heterotrophic microorganisms in the distribution system. We conclude from our results that AOA can be commonly present in distribution systems and groundwater treatment, where they can be responsible for the removal of ammonia

    The influence of particles on biofouling behavior in spiral wound membrane elements

    No full text
    Spiral-wound membrane (SWM) elements for nanofiltration (NF) and reverse osmosis (RO) need pre-treatment to prevent clogging of the feed spacer channel by particles and/or biomass. Usually rapid sand filtration or ultrafiltration is applied for this purpose. The effect of (the removal of) particles on biofouling processes in spiral-wound membrane (SWM) elements was investigated in this work by using a pilot set-up consisting of three parallel SWM elements. Local tap water supplemented with acetate to promote biofouling was fed to (i) a reference element, (ii) an element with one hour of daily dosing of copper sulfate to control biofouling and (iii) a third element with an additional pre-filtration to eliminate particles from the feed water of the element. The additional filter element behaved similarly to the reference element with respect to membrane transfer coefficient (MTC) decrease and pressure drop increase. Also results for membrane autopsy for biological and organic parameters were similar. The results demonstrated that the applied particle removal did not have a significant effect on the biofouling behavior in SWRO elements
    corecore